1.Peel strength of denture liner to PMMA and polyamide: laser versus air-abrasion.
Fatih Mehmet KORKMAZ ; Bora BAGIS ; Mutlu OZCAN ; Rukiye DURKAN ; Sedanur TURGUT ; Sabit Melih ATES
The Journal of Advanced Prosthodontics 2013;5(3):287-295
PURPOSE: This study investigated the effect of laser parameters and air-abrasion on the peel strength of silicon-based soft denture liner to different denture resins. MATERIALS AND METHODS: Specimens (N=180) were prepared out of three different denture base resins (Rodex, cross-linked denture base acrylic resin; Paladent, heat-cured acrylic resin; Deflex, Polyamide resin) (75 mm x 25 mm x 3 mm). A silicon-based soft denture liner (Molloplast B) was applied to the denture resins after the following conditioning methods: a) Air-abrasion (50 microm), b) Er,Cr:YSGG laser (Waterlase MD Turbo, Biolase Technology) at 2 W-20 Hz, c) Er,Cr:YSGG laser at 2 W-30 Hz, d) Er,Cr:YSGG laser at 3 W-20 Hz, e) Er,Cr:YSGG laser at 3 W-30 Hz. Non-conditioned group acted as the control group. Peel test was performed in a universal testing machine. Failure modes were evaluated visually. Data were analyzed using two-way ANOVA and Tukey's test (alpha=.05). RESULTS: Denture liner tested showed increased peel strength after laser treatment with different parameters (3.9+/-0.4 - 5.58+/-0.6 MPa) compared to the control (3.64+/-0.5 - 4.58+/-0.5 MPa) and air-abraded groups (3.1+/-0.6 - 4.46+/-0.3 MPa), but the results were not statistically significant except for Paladent, with the pretreatment of Er,Cr:YSGG laser at 3 W-20 Hz. Polyamide resin after air-abrasion showed significantly lower peel strength than those of other groups (3.1+/-0.6 MPa). CONCLUSION: Heat-cured acrylic resin, PMMA, may benefit from Er,Cr:YSGG laser treatment at 3 W-20 Hz irradiation. Air-abrasion of polyamide resins should be avoided not to impair their peel bond strengths to silicon-based soft denture liners.
Collodion
;
Denture Bases
;
Denture Liners
;
Dentures
;
Nylons
;
Polymethyl Methacrylate
2.Evaluation of penile hemodynamic status and adjustment of treatment alternatives in Peyronie's disease.
Tibet ERDOGRU ; Murat SAVAS ; Namik YILMAZ ; Mustafa Faruk USTA ; Turker KOKSAL ; Mutlu ATES ; Mehmet BAYKARA
Asian Journal of Andrology 2002;4(3):187-190
AIMErectile dysfunction may be observed in up to 80% of patients with Peyronie's disease. An objective evaluation of the erectile function is attempted to work out in patients with Peyronie's disease.
METHODSPenile deformity, sexual function and penile vascular status were analyzed in 123 patients with Peyronie's disease, who had not received any pertinent treatment.
RESULTSPenile deformity, palpable plaque and pain on erection were seen in 112 (91%), 97 (78.8%) and 27 (21.9%) of the 123 patients, respectively. Of the 76 patients evaluated by color Doppler ultrasounography, veno-occlusive dysfunction as the vascular component for erectile dysfunction was found in 17 (22.3%), arterial insufficiency in 10 (13.1%) and a mixed picture in 23 (30.2%).
CONCLUSIONThe documentation of penile erectile function and the determination of the vascular status using color Doppler ultrasonography can guide the appropriate therapeutic choice.
Adult ; Aged ; Antioxidants ; therapeutic use ; Colchicine ; therapeutic use ; Erectile Dysfunction ; diagnostic imaging ; drug therapy ; physiopathology ; Gout Suppressants ; therapeutic use ; Humans ; Male ; Middle Aged ; Penile Induration ; diagnostic imaging ; drug therapy ; physiopathology ; Penis ; blood supply ; pathology ; physiopathology ; Ultrasonography, Doppler, Color ; Vitamin E ; therapeutic use