1.Effectiveness and safety of preoperative distraction using modified halo-pelvic Ilizarov distraction assembly in patients with severe kyphoscoliosis
Muhammad Saad ILYAS ; Abdullah SHAH ; Uruj ZEHRA ; Muhammad ISMAIL ; Haseeb ELAHI ; Amer AZIZ
Asian Spine Journal 2024;18(4):522-531
Methods:
Patients with severe kyphoscoliosis having coronal Cobb angle >90° were applied with modified halo-pelvic Ilizarov distraction assembly preoperatively. The modified assembly consisted of a pelvic component and halo ring, and distraction was given at the rate of 2–3 mm/day for 6–12 weeks. Complete clinical assessments along with pulmonary function tests were performed, and scoliosis series X-ray images were assessed for coronal and sagittal Cobb angle and other spinopelvic parameters before applying the assembly and during 2 years of follow-up.
Results:
Thirty-four patients (age, 9–27 years; male/female ratio of 18:16) were included. The coronal and sagittal Cobb angles were 116°±16.2° and 84°±28.3°, respectively. Correction rates obtained through modified halo-pelvic assembly were nearly 52% (p=0.001) in coronal and 40% (p=0.001) in sagittal Cobb angles, with improvement in height (p=0.001). Apical vertebral translation and coronal balance were also improved significantly (p=0.001). Further improvements in all the parameters were obtained after definitive surgery, with improvements in the forced expiratory volume in 1 second (p =0.002) and forced vital capacity (p=0.001).
Conclusions
Our modified halo-pelvic Ilizarov distraction assembly can achieve good correction in severe spinal deformities without significant risk to neurology, has fewer complications, and promotes good patient compliance.
2.Effectiveness and safety of preoperative distraction using modified halo-pelvic Ilizarov distraction assembly in patients with severe kyphoscoliosis
Muhammad Saad ILYAS ; Abdullah SHAH ; Uruj ZEHRA ; Muhammad ISMAIL ; Haseeb ELAHI ; Amer AZIZ
Asian Spine Journal 2024;18(4):522-531
Methods:
Patients with severe kyphoscoliosis having coronal Cobb angle >90° were applied with modified halo-pelvic Ilizarov distraction assembly preoperatively. The modified assembly consisted of a pelvic component and halo ring, and distraction was given at the rate of 2–3 mm/day for 6–12 weeks. Complete clinical assessments along with pulmonary function tests were performed, and scoliosis series X-ray images were assessed for coronal and sagittal Cobb angle and other spinopelvic parameters before applying the assembly and during 2 years of follow-up.
Results:
Thirty-four patients (age, 9–27 years; male/female ratio of 18:16) were included. The coronal and sagittal Cobb angles were 116°±16.2° and 84°±28.3°, respectively. Correction rates obtained through modified halo-pelvic assembly were nearly 52% (p=0.001) in coronal and 40% (p=0.001) in sagittal Cobb angles, with improvement in height (p=0.001). Apical vertebral translation and coronal balance were also improved significantly (p=0.001). Further improvements in all the parameters were obtained after definitive surgery, with improvements in the forced expiratory volume in 1 second (p =0.002) and forced vital capacity (p=0.001).
Conclusions
Our modified halo-pelvic Ilizarov distraction assembly can achieve good correction in severe spinal deformities without significant risk to neurology, has fewer complications, and promotes good patient compliance.
3.Effectiveness and safety of preoperative distraction using modified halo-pelvic Ilizarov distraction assembly in patients with severe kyphoscoliosis
Muhammad Saad ILYAS ; Abdullah SHAH ; Uruj ZEHRA ; Muhammad ISMAIL ; Haseeb ELAHI ; Amer AZIZ
Asian Spine Journal 2024;18(4):522-531
Methods:
Patients with severe kyphoscoliosis having coronal Cobb angle >90° were applied with modified halo-pelvic Ilizarov distraction assembly preoperatively. The modified assembly consisted of a pelvic component and halo ring, and distraction was given at the rate of 2–3 mm/day for 6–12 weeks. Complete clinical assessments along with pulmonary function tests were performed, and scoliosis series X-ray images were assessed for coronal and sagittal Cobb angle and other spinopelvic parameters before applying the assembly and during 2 years of follow-up.
Results:
Thirty-four patients (age, 9–27 years; male/female ratio of 18:16) were included. The coronal and sagittal Cobb angles were 116°±16.2° and 84°±28.3°, respectively. Correction rates obtained through modified halo-pelvic assembly were nearly 52% (p=0.001) in coronal and 40% (p=0.001) in sagittal Cobb angles, with improvement in height (p=0.001). Apical vertebral translation and coronal balance were also improved significantly (p=0.001). Further improvements in all the parameters were obtained after definitive surgery, with improvements in the forced expiratory volume in 1 second (p =0.002) and forced vital capacity (p=0.001).
Conclusions
Our modified halo-pelvic Ilizarov distraction assembly can achieve good correction in severe spinal deformities without significant risk to neurology, has fewer complications, and promotes good patient compliance.
4.Effectiveness and safety of preoperative distraction using modified halo-pelvic Ilizarov distraction assembly in patients with severe kyphoscoliosis
Muhammad Saad ILYAS ; Abdullah SHAH ; Uruj ZEHRA ; Muhammad ISMAIL ; Haseeb ELAHI ; Amer AZIZ
Asian Spine Journal 2024;18(4):522-531
Methods:
Patients with severe kyphoscoliosis having coronal Cobb angle >90° were applied with modified halo-pelvic Ilizarov distraction assembly preoperatively. The modified assembly consisted of a pelvic component and halo ring, and distraction was given at the rate of 2–3 mm/day for 6–12 weeks. Complete clinical assessments along with pulmonary function tests were performed, and scoliosis series X-ray images were assessed for coronal and sagittal Cobb angle and other spinopelvic parameters before applying the assembly and during 2 years of follow-up.
Results:
Thirty-four patients (age, 9–27 years; male/female ratio of 18:16) were included. The coronal and sagittal Cobb angles were 116°±16.2° and 84°±28.3°, respectively. Correction rates obtained through modified halo-pelvic assembly were nearly 52% (p=0.001) in coronal and 40% (p=0.001) in sagittal Cobb angles, with improvement in height (p=0.001). Apical vertebral translation and coronal balance were also improved significantly (p=0.001). Further improvements in all the parameters were obtained after definitive surgery, with improvements in the forced expiratory volume in 1 second (p =0.002) and forced vital capacity (p=0.001).
Conclusions
Our modified halo-pelvic Ilizarov distraction assembly can achieve good correction in severe spinal deformities without significant risk to neurology, has fewer complications, and promotes good patient compliance.
5.Vertebral Endplate Changes Correlate with Presence of Cartilaginous Endplate in the Herniated Disc Tissue: Factor Predicting Failure of Conservative Treatment
Rabia LATIF ; Sumera IMRAN ; Ijaz AHMAD ; Muhammad Saad ILYAS ; Amer AZIZ ; Uruj ZEHRA
Asian Spine Journal 2022;16(2):212-220
Methods:
Fifty-one discs were obtained from patients undergoing surgery for herniated disc. Their ages ranged from 19-65 years, and 31/51 were male. Pre-surgical T1 and T2 weighted lumbar-spine MRIs were analyzed to observe Pfirrmann grade, VEP defects, herniation type, Modic changes, and high-intensity zones (HIZ) at the affected level. Five-micron thick sections were stained with hematoxylin and eosin, Alcian blue periodic acid–Schiff stain; examined for histological degeneration scores (HDS; 0–15), inflammation (0 [absence]–3 [severe]), and presence of cartilaginous endplate (CEP). Three-micron thick sections were stained with protein-gene-product 9.5 and expression was counted/mm2. Data was analyzed, and p<0.05 was considered to indicate statistical significance.
Results:
VEP defects, Modic changes, and HIZ were respectively observed in 30/51, 16/51, and 6/51 of the samples. CEP was observed in 26/51 samples and in 23/51 with endplate defects. Discs with adjacent VEP defects showed increased HDS (p<0.001) and inflammation (p<0.001). Discs with adjacent Modic changes also revealed increased HDS (p=0.01). Histological sections with CEP showed increased HDS (p<0.001) and inflammation (p<0.001), and nerve density was significantly positively correlated with HDS (r=0.27, p=0.02).
Conclusions
VEP changes can modulate degeneration and inflammation of herniated discs. Presence of these changes is highly predictive of the occurrence of CEP in herniated discs, which leads to slow resorption and persistent clinical symptoms.
6.Orthopaedic Practices and Surgeries during COVID-19 in Pakistan - A Survey Based Study
Saad-Ilyas M ; Zehra U ; Khan UU ; Mohammad I ; Muhammad R ; Aziz A
Malaysian Orthopaedic Journal 2021;15(No.1):72-78
Introduction: The study aimed to target the current practices
of the orthopaedic community in outpatient (OPD),
emergency (ER) and surgical services (OT) during COVID19.
Material and method: This study surveyed 303 orthopaedic
surgeons from all over Pakistan. The survey had 30 questions
targeting the setup of outpatient, emergency and operation
services in orthopaedic departments of different hospitals in
Pakistan.
Result: A total of 302 surgeons were included from 53 cities
all over Pakistan. Between 35-48% of the respondents
reported lack of availability of standard operating procedures
in OPD, ER and in OT. Majority of the respondents noted
that their OPD and surgical practice had been affected to
some degree and 69% of the surgeons were only doing
trauma surgery. This trend was higher in younger consultants
of less than 45 years of age (p<0.001). Almost two-third of
the surgeons, mostly senior (p=0.03) were using surgical
masks as the only protective measure during various
practices of OPD, ER and OT, while most of the setups were
not assessing patients even for signs and symptoms of
COVID. Almost 89% of the orthopaedic community is
facing definite to mild stress during this pandemic and this
has significantly affected the senior surgeons (p=0.01).
Conclusion: Our study highlighted that COVID-19 has
resulted in marked changes to the practices of the majority of
Pakistani orthopaedic surgeons. Despite a sharp upsurge in
the number of cases and mortality due to COVID-19,
guidelines were still lacking at most of the settings and a
substantial percentage of the orthopaedic community were
not following adequate safety measures while attending to
patients.