1.Anaphylactic reaction with hydroxyethyl starch during anesthesia: A case report
Gunnhee KIM ; Goeun KIM ; Miyoung KWON ; Minseok KOO ; Mijung YUN
Anesthesia and Pain Medicine 2019;14(4):412-415
BACKGROUND: Hydroxyethyl starch (HES), a class of synthetic colloid solutions, has been widely used to treat perioperative hypovolemia. The use of HES, however, is associated with the risk of allergic reactions.CASE: An 83-year-old man was scheduled to undergo an open reduction and internal fixation of a pertrochanteric fracture under spinal anesthesia. He had no history of allergy. Five minutes after HES administration, hypotension, agitation, and skin rash were developed. HES infusion was terminated due to a suspected anaphylactic reaction. The vital signs recovered following administration of phenylephrine, dexamethasone, and hydrocortisone. Serum tryptase and total immunoglobulin E levels were elevated in plasma samples collected following the commencement of the allergic reaction during surgery.CONCLUSIONS: In the present report, the risk of anaphylactic reaction with HES and the laboratory tests needed to support the diagnosis are highlighted.
Aged, 80 and over
;
Anaphylaxis
;
Anesthesia
;
Anesthesia, Spinal
;
Colloids
;
Dexamethasone
;
Diagnosis
;
Dihydroergotamine
;
Exanthema
;
Humans
;
Hydrocortisone
;
Hypersensitivity
;
Hypotension
;
Hypovolemia
;
Immunoglobulin E
;
Immunoglobulins
;
Phenylephrine
;
Plasma
;
Starch
;
Tryptases
;
Vital Signs
2.Comparison of Two Different Segmentation Methods on Planar Lung Perfusion Scan with Reference to Quantitative Value on SPECT/CT
Minseok SUH ; Yeon koo KANG ; Seunggyun HA ; Yong il KIM ; Jin Chul PAENG ; Gi Jeong CHEON ; Samina PARK ; Young Tae KIM ; Dong Soo LEE ; E Edmund KIM ; June Key CHUNG
Nuclear Medicine and Molecular Imaging 2017;51(2):161-168
PURPOSE: Until now, there was no single standardized regional segmentation method of planar lung perfusion scan.We compared planar scan based two segmentation methods, which are frequently used in the Society of Nuclear Medicine, with reference to the lung perfusion single photon emission computed tomography (SPECT)/computed tomography (CT) derived values in lung cancer patients.METHODS: Fifty-five lung cancer patients (male:female, 37:18; age, 67.8 ± 10.7 years) were evaluated. The patients underwent planar scan and SPECT/CT after injection of technetium-99 m macroaggregated albumin (Tc-99 m-MAA). The % uptake and predicted postoperative percentage forced expiratory volume in 1 s (ppoFEV1%) derived from both posterior oblique (PO) and anterior posterior (AP) methods were compared with SPECT/CT derived parameters. Concordance analysis, paired comparison, reproducibility analysis and spearman correlation analysis were conducted.RESULTS: The % uptake derived from PO method showed higher concordance with SPECT/CT derived % uptake in every lobe compared to AP method. Both methods showed significantly different lobar distribution of%uptake compared to SPECT/CT. For the target region, ppoFEV1% measured from PO method showed higher concordance with SPECT/CT, but lower reproducibility compared to AP method. Preliminary data revealed that every method significantly correlated with actual postoperative FEV1%, with SPECT/CT showing the best correlation.CONCLUSIONS: The PO method derived values showed better concordance with SPECT/CT compared to the AP method. Both PO and AP methods showed significantly different lobar distribution compared to SPECT/CT. In clinical practice such difference according to different methods and lobes should be considered for more accurate postoperative lung function prediction.
Forced Expiratory Volume
;
Humans
;
Lung Neoplasms
;
Lung
;
Matched-Pair Analysis
;
Methods
;
Nuclear Medicine
;
Perfusion Imaging
;
Perfusion
;
Tomography, Emission-Computed, Single-Photon