PURPOSE: This in vitro study evaluated the effects of four different cements on the color attributes of a zirconia ceramic. MATERIALS AND METHODS: 40 zirconia ceramic disk specimens (0.5 mm thickness, 10 mm diameter, 0.1 mm cement space) were fabricated by a computer-aided design and computer-aided manufacturing system. The specimens were divided into 4 groups of 10 specimens and cemented to composite substrates using four different cements including: Glass Ionomer, Panavia F2.0, Zinc Phosphate, and TempBond. The L*, a*, and b* color attributes of the specimens were measured before and after cementation by a spectrophotometer. Additionally, ΔE values were measured to determine color changes for the groups and then compared with the perceptional threshold of ΔE = 3.3. Repeated Measures ANOVA, Tukey Post Hoc, Bonferroni, One-way ANOVA, and One-sample t-test tests were used to analyze the data. All tests were carried out at the 0.05 level of significance. RESULTS: Statistically significant differences were detected in the ΔE values for Zinc Phosphate (P<.0001) and TempBond (P<.0001) groups. However, there were no statistically significant differences in this respect for Glass Ionomer (P=.99) and Panavia F2.0 (P=1) groups. The means and standard deviations of the ΔE values for Glass Ionomer, Panavia F2.0, Zinc Phosphate, and Tempbond groups were 2.11±0.66, 0.94±0.39, 5.77±0.83, and 7.50±1.16 Unit, respectively. CONCLUSION: Within the limitations of this study, it was concluded that Zinc Phosphate and Tempbond cements affected the color attributes of the tested zirconia ceramic beyond the perceptional threshold. However, Glass Ionomer and Panavia F2.0 cements created acceptable color changes.
Cementation
;
Ceramics*
;
Computer-Aided Design
;
Dental Cements
;
Glass
;
In Vitro Techniques
;
Spectrophotometry
;
Zinc
2.The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices.
Minoo MAHSHID ; Aboulfazl SABOURY ; Seyed Jalil SADR ; Ali FAYYAZ ; Mahdi KADKHODAZADEH
Journal of Periodontal & Implant Science 2013;43(5):221-226
PURPOSE: This study aimed to assess the combined effect of dismantling before sterilization and aging on the accuracy (+/-10% of the target torque) of spring-style mechanical torque devices (S-S MTDs). METHODS: Twenty new S-SMTDs from two different manufacturers (Nobel Biocare and Straumann: 10 of each type) were selected and divided into two groups, namely, case (group A) and control (group B). For sterilization, 100 cycles of autoclaving were performed in 100 sequences. In each sequence, 10 repetitions of peak torque values were registered for aging. To measure and assess the output of each device, a Tohnichi torque gauge was used (P<0.05). RESULTS: Before steam sterilization, all of the tested devices stayed within 10% of their target values. After 100 cycles of steam sterilization and aging with or without dismantling of the devices, the Nobel Biocare devices stayed within 10% of their target torque. In the Straumann devices, despite the significant difference between the peak torque and target torque values, the absolute error values stayed within 10% of their target torque. CONCLUSION: Within the limitations of this study, there was no significant difference between the mean and absolute value of error between Nobel Biocare and Straumann S-S MTDs.
Aging*
;
Dental Implants
;
Steam*
;
Sterilization*
;
Torque*