1.Effect of Cataract Grade according to Wide-Field Fundus Images on Measurement of Macular Thickness in Cataract Patients.
Mingue KIM ; Youngsub EOM ; Jong Suk SONG ; Hyo Myung KIM
Korean Journal of Ophthalmology 2018;32(3):172-181
PURPOSE: To investigate the effects of cataract grade based on wide-field fundus imaging on macular thickness measured by spectral domain optical coherence tomography (SD-OCT) and its signal-to-noise ratio (SNR). METHODS: Two hundred cataract patients (200 eyes) with preoperative measurements by wide-field fundus imaging and macular SD-OCT were enrolled. Cataract severity was graded from 1 to 4 according to the degree of macular obscuring by cataract artifact in fundus photo images. Cataract grade based on wide-field fundus image, the Lens Opacity Classification System III, macular thickness, and SD-OCT SNR were compared. All SD-OCT B-scan images were evaluated to detect errors in retinal layer segmentation. RESULTS: Cataract grade based on wide-field fundus imaging was positively correlated with grade of posterior subcapsular cataracts (rho = 0.486, p < 0.001), but not with nuclear opalescence or cortical cataract using the Lens Opacity Classification System III. Cataract grade was negatively correlated with total macular thickness (rho = −0.509, p < 0.001) and SD-OCT SNR (rho = −0.568, p < 0.001). SD-OCT SNR was positively correlated with total macular thickness (rho = 0.571, p < 0.001). Of 200 eyes, 97 (48.5%) had segmentation errors on SD-OCT. As cataract grade increased and SD-OCT SNR decreased, the percentage of eyes with segmentation errors on SD-OCT increased. All measurements of macular thickness in eyes without segmentation errors were significantly greater than those of eyes with segmentation errors. CONCLUSIONS: Posterior subcapsular cataracts had profound effects on cataract grade based on wide-field fundus imaging. As cataract grade based on wide-field fundus image increased, macular thickness tended to be underestimated due to segmentation errors in SD-OCT images. Segmentation errors in SD-OCT should be considered when evaluating macular thickness in eyes with cataracts.
Artifacts
;
Cataract*
;
Classification
;
Fundus Oculi
;
Humans
;
Iridescence
;
Retinaldehyde
;
Signal-To-Noise Ratio
;
Tomography, Optical Coherence
2.Clinical Outcomes of ATOS-mediated SmartSight Lenticule Extraction
Chang Mok LEE ; Hyo Sung YOON ; Hye Ra KANG ; Mingue KIM ; Sheen Chull JOH ; Dong Ju YEOM
Journal of the Korean Ophthalmological Society 2023;64(8):666-671
Purpose:
To evaluate the clinical outcomes of a new refractive corneal lenticule extraction method (SmartSight) using a Schwind ATOS femtosecond laser (Schwind Eye-Tech-Solutions, Kleinostheim, Germany).
Methods:
The medical records of 338 eyes of 170 patients who underwent SmartSight treatment from April to September 2022 and were followed-up for at least 3 months were retrospectively analyzed. The patients were followed-up at 1 day, 1 week, and 1 and 3 months after operation. Refraction, visual acuity, and intraocular pressure were measured at each visit.
Results:
Preoperatively, the uncorrected distant visual acuity was 1.26 ± 0.33 logarithm of minimum angle or resolution (logMAR) and the spherical equivalent was -4.52 ± 1.77 diopters. The 3-month, postoperative, uncorrected distant visual acuity was 0.01 ± 0.03 logMAR and the spherical equivalent was -0.12 ± 0.22 diopters. The 3-month data were as follows: efficacy of refractive surgery, 0.99 ± 0.11; safety, 1.00 ± 0.05; predictabilities at ±0.5 and ± 1.0 diopters, 97% and 100%, respectively.
Conclusions
Myopic astigmatism correction using the SmartSight method was effective, safe, and predictable in terms of visual outcomes.