1.Clinical efficacy analysis of arthroscopic treatment for hallux ganglion cyst deriving from ankle joint
Qinglin ZHANG ; Lei CHEN ; Mingtong HAN ; Baoqiang XU ; Yong HU ; Zhengxun LI
Chinese Journal of Surgery 2023;61(11):982-988
Objective:To investigate the pathogenesis and clinical efficacy of arthroscopic treatment for hallux ganglion cyst deriving from ankle joint.Methods:The clinical data of 21 patients with ankle arthroscopic in the Department of Hand and Foot Surgery,Affiliated Hospital of Jining Medical College from January 2019 to March 2021 were analyzed retrospectively.There were 15 male cases and 6 female cases,aged (52.6±8.2) years (range:42 to 70 years).There were 9 cases of primary operation and 12 cases of recurrence after operation in other hospital.All the patients were examined by ankle arthrography and MRI before operation.The synovial membrane of the ankle was debrided and the tendon sheath of flexor longus was removed at the ankle canal.One year after operation,MRI was performed,and the American Orthopedic Foot and Ankle Society(AOFAS) score of forefoot function and visual analogue scale (VAS) before and after operation were compared by the paired t test or Mann-Whitney U test.The postoperative complications and recurrence were recorded. Results:All patients were operated successfully.The joint capsule at the back of the ankle joint of the patients were ruptured and communicated with the tendon sheath of the flexor longus tendon at the ankle canal.No wound infection,vascular and nerve injury occurred.The follow-up period was (15.0±2.2) months (range:12 to 18 months).During the follow-up period,there was no recurrence of toe appearance and MRI.At the last follow-up,the AOFAS score (90.8±4.3) was significantly higher than that before operation (72.8±6.3) ( t=-10.810, P<0.01),and the VAS score( M(IQR)) was significantly lower than that before operation,the difference was significant (1.0(1.0) vs. 3.0(0.5), Z=-4.081, P<0.01). Conclusions:The possible mechanism of hallux ganglion cyst deriving from ankle joint is that the joint capsule at the back of the ankle joint ruptures and communicates with the tendon sheath of the flexor longus tendon at the ankle canal,and the intra-articular synovial fluid through the cylinder effect generated by sliding with the flexor tendon of the flexor longus tendon in the tendon sheath sac leads to the heel valange cyst.Ankle-synovial cleansing of the ankle joint under ankle arthroscopy and resection of the flexor tendon sheath of the flexor longus tendon at the ankle canal are effective and less invasive.
2.Clinical efficacy analysis of arthroscopic treatment for hallux ganglion cyst deriving from ankle joint
Qinglin ZHANG ; Lei CHEN ; Mingtong HAN ; Baoqiang XU ; Yong HU ; Zhengxun LI
Chinese Journal of Surgery 2023;61(11):982-988
Objective:To investigate the pathogenesis and clinical efficacy of arthroscopic treatment for hallux ganglion cyst deriving from ankle joint.Methods:The clinical data of 21 patients with ankle arthroscopic in the Department of Hand and Foot Surgery,Affiliated Hospital of Jining Medical College from January 2019 to March 2021 were analyzed retrospectively.There were 15 male cases and 6 female cases,aged (52.6±8.2) years (range:42 to 70 years).There were 9 cases of primary operation and 12 cases of recurrence after operation in other hospital.All the patients were examined by ankle arthrography and MRI before operation.The synovial membrane of the ankle was debrided and the tendon sheath of flexor longus was removed at the ankle canal.One year after operation,MRI was performed,and the American Orthopedic Foot and Ankle Society(AOFAS) score of forefoot function and visual analogue scale (VAS) before and after operation were compared by the paired t test or Mann-Whitney U test.The postoperative complications and recurrence were recorded. Results:All patients were operated successfully.The joint capsule at the back of the ankle joint of the patients were ruptured and communicated with the tendon sheath of the flexor longus tendon at the ankle canal.No wound infection,vascular and nerve injury occurred.The follow-up period was (15.0±2.2) months (range:12 to 18 months).During the follow-up period,there was no recurrence of toe appearance and MRI.At the last follow-up,the AOFAS score (90.8±4.3) was significantly higher than that before operation (72.8±6.3) ( t=-10.810, P<0.01),and the VAS score( M(IQR)) was significantly lower than that before operation,the difference was significant (1.0(1.0) vs. 3.0(0.5), Z=-4.081, P<0.01). Conclusions:The possible mechanism of hallux ganglion cyst deriving from ankle joint is that the joint capsule at the back of the ankle joint ruptures and communicates with the tendon sheath of the flexor longus tendon at the ankle canal,and the intra-articular synovial fluid through the cylinder effect generated by sliding with the flexor tendon of the flexor longus tendon in the tendon sheath sac leads to the heel valange cyst.Ankle-synovial cleansing of the ankle joint under ankle arthroscopy and resection of the flexor tendon sheath of the flexor longus tendon at the ankle canal are effective and less invasive.
3.Scan time and accuracy of full-arch scans with intraoral scanners: a comparative study on conditions of the intraoral head-simulator and the hand-held model
Mingtong WU ; Suxia TANG ; Lingyan PENG ; Yuting HAN ; Yucheng SU ; Xia WANG
Chinese Journal of Stomatology 2021;56(6):570-575
Objective:To comparatively evaluate the scan time and the accuracy of maxillary full-arch scans using four intraoral scanners (IOS) on conditions of the intraoral head-simulator and the hand-held model, and to evaluate the influence of different scanning conditions on digital scan.Methods:A upper dental arch model with melamine-formaldehyde resin teeth and silica gel gingiva that could be fixed on a head simulator was scanned with an optical scanner (ATOS Core) in order to obtain the standard tessellation language dataset as reference. Intraoral scans were performed on the model fixed on the head simulator by three researchers with four IOS [A: TRIOS 3; B: CS 3600; C: CEREC Omnicam; D: iTero]. For each scanner and each researcher, six scans were performed, to obtain the datasets as the head simulator group. And another six scans with each of the four intraoral scanners were performed by each researcher on the hand-held model to obtain the STL datasets as the hand-held group. The scan time were recorded for each scan. In the Geomagic Wrap software, the digital models were trimmed with only the teeth information retained and supreimposed by best fit alignment function and compared to obtain the root mean square (RMS) values of the discrepancies by three-dimensional compare function. The test datasets of each group were compared with the reference dataset for trueness. The six test scanning datasets with the same scanner of the same researcher were cross compared for precision. Mann Whitney U test was used to statistically analyze the difference values of the scan time, trueness and precision of the same intraoral scanner between head simulator group and hand-held group. Results:Compared to the hand-held group, the scan time of A [142(82) s] and D [119(52) s], which two IOS both with handle, were longer in head simulator group [A: 98(28) s; D: 85(22) s] ( P<0.01). However there were no significant differences between the two groups for scan time of IOS B and C ( P>0.05). For full-arch scan accuracy (trueness and precision), there were no significant differences between the two groups of IOS A and B ( P>0.05), while the trueness of C ( P<0.05) and the precision of D ( P<0.01) were better in head simulator group [C: 112(38) μm; D: 43(13) μm] compared to hand-held group [C: 135(47) μm; D: 53(18) μm]. However, there were no significant differences for the precision of C ( P>0.05) and the trueness of D ( P>0.05). Conclusions:The scan time and the accuracy of full-arch digital scans with different IOS may be effected by the scan conditions. For in vitro study of intraoral scanning, head-simulator can simulate the intraoral environment of the real patient to some extent. Meanwhile, the position of the dentist and the patient, and also the limited intraoral space during intraoral scanning are also simulated.