1.Effect of staphylococcal protein A on pro-inflammatory cytokines expression in mononuclear macrophage
Xinglong MA ; Yulin HUANG ; Xiaoqing CHEN ; Mingqiang LI ; Qingmeng LIU
Chongqing Medicine 2016;45(11):1484-1487
Objective To study the expression and regulation of pro‐inflammatory cytokinesTNF‐α,IL‐1 ,IL‐6 in mononucle‐ar macrophages stimulated with staphylococcal protein A (SpA) .Methods THP‐1 was incubated with PMA and induced into mononuclear macrophages .Then the macrophages were incubated with varying concentrations of SpA under different time points . The effect of SpA on macrophage proliferation was measured by MTT method .The levels of inflammatory cytokines ,TNF‐α,IL‐1 and IL‐6 from the cultured cell media were measured by ELISA respectively .The levels of mRNA expression corresponding to TNF‐α,IL‐1 and IL‐6 were detected by RT‐PCR from the macrophages stimulated with SpA .All statistical analyses were performed by SPSS17 .0 software .Results The MTT result indicated that SpA had a positive effect on the proliferation of THP‐1 cells in a dosage depended manner .The addition of SpA could enhance the mRNA expression of TNF‐α,IL‐1 and IL‐6 in the stimulated mac‐rophages .It also showed a specific dose‐effect and time‐effect correlation .The macrophages secreted inflammatory cytokines and its corresponding mRNA reached its peak levels at 12 h post stimulation .Compared with the control group ,the expression and release of TNF‐α,IL‐1 and IL‐6 in macrophages from the experimental group was increased with statistical significance(P<0 .01) .Conclu‐sion SpA can promote the secretion and expression of early pro‐inflammatory cytokines ,such as TNF‐α,IL‐1 and IL‐6 in macro‐phages .Therefore ,SpA plays a very important role in the initiation and development of the staphylococcus aureus sepsis .
2.Follow-up assessment of "Technical specifications for occupational health surveillance".
Ying ZHAO ; Han WANG ; Weiguo CHEN ; Chengmin XU ; Mingqiang MA ; Ainan ZHU ; Yaling QIAN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2014;32(4):264-267
OBJECTIVETo investigate the possession of occupational health examination qualification among occupational health examination institutions in Zhejiang province, China and the application of GBZ188-2007 "Technical specifications for occupational health surveillance" among related government departments, and to provide a basis for revising and improving the specifications.
METHODSA questionnaire survey was carried out among occupational health inspection agencies, health supervision authorities, and enterprises of different sizes, which possessed provincial-level occupation health inspection qualifications and had engaged in occupational health examination for more than 2 years. The investigation included awareness, using frequency, and revision suggestion about GBZ 188-2007 "Technical specifications for occupational health surveillance".
RESULTSMedical institutions and centers for disease control and prevention (CDCs)showed a high rate of occupational health examination qualification possession in chemical substances, dust, noise, and high temperature and a low rate of qualification possession in physical factors, biological factors, special operations, and other aspects. These institutions showed high awareness of chemical substances, dust, and physical factors in GBZ 188-2007 "Technical specifications for occupational health surveillance" and low awareness of other factors. Medical institutions, CDCs, and provincial and municipal health supervision authorities used these specifications more frequently than county-level authorities and enterprises. More than 80% investigated units believed that the following issues required further optimization: occupational health care, emergency health examination regulations, classification of occupational health inspection reports, and special operation monitoring. It is consistently stressed that for exposure to chemical compounds that may bring harm to various organs of the body, explicit specifications should be made concerning health examination before, during, and after service. Conflicting opinions existed concerning the following issues: satisfaction with GBZ 188-2007 specifications, whether to add contents for care of personnel exposed to biological factors (such as forest encephalitis), the threshold of noise intensity to perform health care, and whether to add health care for exposure to compounds such as benzene and phenols.
CONCLUSIONThe occupational health inspection agencies in Zhejiang province have a high rate of qualification possession in health examination concerning chemicals, dust, noise, and high temperature. The medical institutions, CDCs, and health supervision departments above the county level often use the specifications at work. It is consistently recommended that more kinds of harmful substances should be included, and related specifications and issues should be further optimized, in order to better meet the requirement of occupational health care in the new era.
China ; Humans ; Occupational Exposure ; Occupational Health Services ; standards
3.Validation of a cell infection-based quantitative RT-PCR for evaluation of rotavirus vaccine potency
Yueyue LIU ; Yunqi ZHANG ; Yan LIU ; Yunjin WANG ; Mingqiang WANG ; Yan ZHAO ; Jialiang DU ; Chao MA ; Xu ZHOU ; Tai GUO
Chinese Journal of Microbiology and Immunology 2019;39(7):532-537
Objective To validate a cell infection-based quantitative RT-PCR for evaluating the potency of rotavirus vaccine. Methods According to the ICH ( the International Council for Harmonization) Harmonised Tripartite Guideline, the method was validated for its specificity, accuracy, precision, linearity and robustness. Results The method had good specificity as it could only amplify and detect the corre-sponding type of rotavirus strain. The recovery rates for determining the potency against rotaviruses of G2, G3 and G4 types were 97% to 108%. The percent coefficient of variation ( CV) of both intra-plate and in-ter-plate precision was≤2. 62%, while the intraday and interday CV was≤1. 76% and≤2. 27%, respec-tively. The CV between the two experimenters was≤7. 68%. The linearity range of the method was 4. 4-6. 5 UI for G2 type rotavirus, 3. 9-8. 3 UI for G3 type and 3. 5-8. 1 UI for G4 type. Good robustness was observed using the cells of 140 to 160 generations. Conclusions The cell infection-based quantitative RT-PCR was shown to have satisfactory specificity, accuracy, precision, linearity and robustness, suggesting that it was a suitable method for evaluating the potency of multivalent rotavirus live vaccines.
4. The impact of male circumcision on the natural history of genital HPV infection: a prospective cohort study
Feixue WEI ; Meng GUO ; Xinjing MA ; Yue HUANG ; Ya ZHENG ; Lin WANG ; Yan SUN ; Sijie ZHUANG ; Kai YIN ; Yingying SU ; Shoujie HUANG ; Mingqiang LI ; Ting WU ; Jun ZHANG
Chinese Journal of Preventive Medicine 2018;52(5):486-492
Objective:
To analyze the correlation between circumcision and incidence and clearance of male genital HPV infection.
Methods:
From May to July 2014, 18-55 year old men who had sexual behavior history were recruited from the general population in Liuzhou, Guangxi to set up a cohort. Totally, 113 circumcised and 560 uncircumcised men were enrolled and interviewed using a questionnaire (including information on demographic characteristics and sexual behaviors), then they were followed-up with 6-month interval for 2 times. On each visit, specimens of male external genitalia were collected and genotyped for HPV DNA. The differences of incidence and clearance of genital HPV infections between circumcised and uncircumcised men were analyzed by Log-rank test. Cox regression was used to analyze the relationship between circumcision and incidence and clearance of HPV infection.
Results:
The median age (
5.Establishment of a deep feature-based classification model for distinguishing benign and malignant breast tumors on full-filed digital mammography.
Cuixia LIANG ; Mingqiang LI ; Zhaoying BIAN ; Wenbing LV ; Dong ZENG ; Jianhua MA
Journal of Southern Medical University 2019;39(1):88-92
OBJECTIVE:
To develop a deep features-based model to classify benign and malignant breast lesions on full- filed digital mammography.
METHODS:
The data of full-filed digital mammography in both craniocaudal view and mediolateral oblique view from 106 patients with breast neoplasms were analyzed. Twenty-three handcrafted features (HCF) were extracted from the images of the breast tumors and a suitable feature set of HCF was selected using -test. The deep features (DF) were extracted from the 3 pre-trained deep learning models, namely AlexNet, VGG16 and GoogLeNet. With abundant breast tumor information from the craniocaudal view and mediolateral oblique view, we combined the two extracted features (DF and HCF) as the two-view features. A multi-classifier model was finally constructed based on the combined HCF and DF sets. The classification ability of different deep learning networks was evaluated.
RESULTS:
Quantitative evaluation results showed that the proposed HCF+DF model outperformed HCF model, and AlexNet produced the best performances among the 3 deep learning models.
CONCLUSIONS
The proposed model that combines DF and HCF sets of breast tumors can effectively distinguish benign and malignant breast lesions on full-filed digital mammography.
Breast Neoplasms
;
classification
;
diagnostic imaging
;
Deep Learning
;
Diagnosis, Computer-Assisted
;
methods
;
Female
;
Humans
;
Mammography
;
methods
6.Design and optimization of a cone-beam CT system for extremity imaging.
Kun MA ; Mingqiang LI ; Xi TAO ; Dong ZENG ; Yongbo WANG ; Zhaoying BIAN ; Ziquan WEI ; Gaofeng CHEN ; Qianjin FENG ; Jianhua MA ; Jing HUANG
Journal of Southern Medical University 2018;38(11):1331-1337
OBJECTIVE:
To establish a cone beam computed tomography (ECBCT) system for high-resolution imaging of the extremities.
METHODS:
Based on three-dimensional X-Ray CT imaging and high-resolution flat plate detector technique, we constructed a physical model and a geometric model for ECBCT imaging, optimized the geometric calibration and image reconstruction methods, and established the scanner system. In the experiments, the pencil vase phantom, image quality (IQ) phantom and a swine feet were scanned using this imaging system to evaluate its effectiveness and stability.
RESULTS:
On the reconstructed image of the pencil vase phantom, the edges were well preserved with geometric calibrated parameters and no aliasing artifacts were observed. The reconstructed images of the IQ phantom showed a uniform distribution of the CT number, and the noise power spectra were stable in multiple scanning under the same condition. The reconstructed images of the swine feet had clearly displayed the bones with a good resolution.
CONCLUSIONS
The ECBCT system can be used for highresolution imaging of the extremities to provide important imaging information to assist in the diagnosis of bone diseases.
Algorithms
;
Animals
;
Artifacts
;
Calibration
;
Cone-Beam Computed Tomography
;
instrumentation
;
methods
;
Equipment Design
;
Extremities
;
diagnostic imaging
;
Image Processing, Computer-Assisted
;
methods
;
Phantoms, Imaging
;
Radiographic Image Enhancement
;
instrumentation
;
methods
;
Swine
7.Key technologies in digital breast tomosynthesis system:theory, design, and optimization.
Mingqiang LI ; Kun MA ; Xi TAO ; Yongbo WANG ; Ji HE ; Ziquan WEI ; Geofeng CHEN ; Sui LI ; Dong ZENG ; Zhaoying BIAN ; Guohui WU ; Shan LIAO ; Jianhua MA
Journal of Southern Medical University 2019;39(2):192-200
OBJECTIVE:
To develop a digital breast tomosynthesis (DBT) imaging system with optimizes imaging chain.
METHODS:
Based on 3D tomography and DBT imaging scanning, we analyzed the methods for projection data correction, geometric correction, projection enhancement, filter modulation, and image reconstruction, and established a hardware testing platform. In the experiment, the standard ACR phantom and high-resolution phantom were used to evaluate the system stability and noise level. The patient projection data of commercial equipment was used to test the effect of the imaging algorithm.
RESULTS:
In the high-resolution phantom study, the line pairs were clear without confusing artifacts in the images reconstructed with the geometric correction parameters. In ACR phantom study, the calcified foci, cysts, and fibrous structures were more clearly defined in the reconstructed images after filtering and modulation. The patient data study showed a high contrast between tissues, and the lesions were more clearly displayed in the reconstructed image.
CONCLUSIONS
This DBT imaging system can be used for mammary tomography with an image quality comparable to that of commercial DBT systems to facilitate imaging diagnosis of breast diseases.
Algorithms
;
Artifacts
;
Breast
;
diagnostic imaging
;
Female
;
Humans
;
Mammography
;
methods
;
Phantoms, Imaging
;
Radiographic Image Enhancement
;
methods
8.Sparse-view helical CT reconstruction based on tensor total generalized variation minimization.
Gaofeng CHEN ; Yongbo WANG ; Zhaoying BIAN ; Ziquan WEI ; Yaohong DENG ; Mingqiang LI ; Kun MA ; Xi TAO ; Bin LI ; Jianhua MA ; Jing HUANG
Journal of Southern Medical University 2019;39(10):1213-1220
OBJECTIVE:
We propose a sparse-view helical CT iterative reconstruction algorithm based on projection of convex set tensor total generalized variation minimization (TTGV-POCS) to reduce the X-ray dose of helical CT scanning.
METHODS:
The three-dimensional volume data of helical CT reconstruction was viewed as the third-order tensor. The tensor generalized total variation (TTGV) was used to describe the structural sparsity of the three-dimensional image. The POCS iterative reconstruction framework was adopted to achieve a robust result of sparse-view helical CT reconstruction. The TTGV-POCS algorithm fully used the structural sparsity of first-order and second-order derivation and the correlation between the slices of helical CT image data to effectively suppress artifacts and noise in the image of sparse-view reconstruction and better preserve image edge information.
RESULTS:
The experimental results of XCAT phantom and patient scan data showed that the TTGVPOCS algorithm had better performance in reducing noise, removing artifacts and maintaining edges than the existing reconstruction algorithms. Comparison of the sparse-view reconstruction results of XCAT phantom data with 144 exposure views showed that the TTGV-POCS algorithm proposed herein increased the PSNR quantitative index by 9.17%-15.24% compared with the experimental comparison algorithm; the FSIM quantitative index was increased by 1.27%-9.30%.
CONCLUSIONS
The TTGV-POCS algorithm can effectively improve the image quality of helical CT sparse-view reconstruction and reduce the radiation dose of helical CT examination to improve the clinical imaging diagnosis.