1.Principle and implementation of list-mode image reconstruction in PET.
Bin ZHANG ; Baoci SHAN ; Mingkai YUN ; Shujun ZHAO
Journal of Biomedical Engineering 2012;29(5):814-819
Positron emission tomography (PET) has become basic support equipment in clinical and many other scientific research fields and has been a hot research field at present. Tomography reconstruction algorithm is a key component of PET, and most PETs use statistical iterative reconstruction algorithms from sinograms data currently. However, tomography reconstruction from list-mode data possesses many unique advantages, and it has caused great attention and is in the process of rapid development and improvementin recently. We eventually achieved list-mode tomography reconstruction in this paper, using experimental data of small animal PET scanner Eplus-166, exploiting S-LMEM algorithm and orthogonal distance-based ray-tracer. The results demonstrated that image resolution and contrast recovery achieved inherent properties of the scanner and on-the-fly ray-tracing methods is feasible for dynamic reconstruction.
Algorithms
;
Humans
;
Image Processing, Computer-Assisted
;
Imaging, Three-Dimensional
;
methods
;
Models, Theoretical
;
Positron-Emission Tomography
;
methods
2.Effects of remote ischemic conditioning in pigs with acute myocardial infarction evaluated by serially gated 99Tc m-MIBI SPECT/CT and 18F-FDG PET/CT
Yao LU ; Yi TIAN ; Tiantian MOU ; Jing TIAN ; Yihan ZHOU ; Wanwan WEN ; Mingkai YUN ; Hongzhi MI ; Xiang LI ; Xiaoli ZHANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2021;41(2):104-109
Objective:To evaluate the effect of remote ischemic conditioning (RIC) on left ventricular (LV) myocardial perfusion, myocardial viability, LV remodeling, regional and global LV function serially following acute myocardial infarction (AMI) in Chinese mini-pigs.Methods:AMI was established in 12 Chinese mini-pigs (8 males, 4 females; age: 6-8 months) and they were randomly divided into RIC group ( n=6) and non-RIC group ( n=6). RIC was performed in pigs by blood pressure inflation on the lower limbs for 5 min period and 4 cycles immediately after surgery. A series of myocardial perfusion imaging and gated 18F-fluorodeoxyglucose (FDG) myocardial metabolism PET/CT imaging were performed longitudinally at the 1st, 14th, 28th and 56th days after AMI, and parameters including total perfusion defect (TPD), hibernating myocardium (HM), Scar, left ventricular ejection fraction (LVEF), left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), summed motion score (SMS), summed thickening score (STS) and changes of these parameters were obtained. Independent-samples t test and Mann-Whitney U test were used to analyze data. Results:Nine Chinese mini-pigs survived after surgery and were performed imaging. Compared to non-RIC group ( n=4), HM at the 28th ((6.0±2.4)% vs (17.0±4.6)%; t=-4.158), TPD 14th-1st ((-11.8±5.4)% vs 9.0%(4.5%, 15.0%); z=2.449), TPD 28th-1st ((-15.3±3.9)% vs (12.0±3.0)%; t=-10.071), TPD 56th-1st ((-18.0±6.5)% vs 9.0%(4.5%, 12.0%); z=2.449), HM 28th-1st ((-10.5±6.9)% vs (8.3±2.1)%; t=-4.507), HM 56th-1st (-15.0%(-17.5%, -8.5%) vs 2.0%(0%, 7.0%); z=2.449) and LVEDV 14th-1st (-0.5(-2.5, 0) ml vs (13.0±4.4) ml; z=2.470) were reduced in RIC group ( n=5; all P<0.05). Conclusion:RIC can improve myocardial perfusion, delay LV remodeling in the acute stage and salvage hibernating myocardium in the subacute stage and chronic stage.
3.Serially evaluation of changes in myocardial perfusion, hibernation myocardium and left ventricular function in the development of chronic coronary artery occlusion by gated SPECT perfusion and gated PET imaging in pigs
Ying ZHANG ; Yi TIAN ; Tiantian MOU ; Mingkai YUN ; Ziwei ZHU ; Yao LU ; Jingjing MENG ; Wei DONG ; Xiang LI ; Xiaoli ZHANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2022;42(5):284-288
Objective:To serially characterize the myocardial perfusion, myocardial hibernation and left ventricular (LV) function as well as LV remodeling in progressive coronary artery stenosis in Chinese mini-pigs.Methods:In 8 Chinese mini-pigs (5 males, 3 females; age: 10 months), chronic progression of coronary stenosis and finally occlusion was established using Ameroid constrictor implantation at the 1 cm below the bifurcation of the first diagonal branch of the left anterior descending (LAD) artery. Serial gated 99Tc m-methoxyisobutylisonitrile(MIBI) SPECT/CT, gated 18F-FDG PET/CT imaging and coronary angiography (CAG) were performed before surgery and at the 1st, 4th and 8th week after surgery. Longitudinally, total perfusion defect (TPD), LV ejection fraction (LVEF), LV end-diastolic volume (LVEDV), LV end-systolic volume (LVESV), summed motion score (SMS), summed thickening score (STS) and hibernating myocardium (HM) were analyzed. Repeated measures analysis of variance, Kruskal-Wallis rank sum test and Bonferroni correction method were used to analyze data. Results:One mini-pig died of infection after the Ameroid constrictor implantation. In the remaining 7 mini-pigs, TPD was progressively increased with time prolonged (0, 12.0%(0, 33.0%), (41.1±23.7)% and (49.3±24.5)%; H=17.03, P=0.001); Compared with HM before the surgery (100%), HM was gradually reduced from the 1st (21.0%(6.0%, 100%)) to the 4th (18.0%(3.0%, 33.0%)) week after surgery, and then increased to the 8th week after surgery ((23.0±15.4)%; H=13.09, P=0.004), but there was no significant difference between the 1st and 4th week, or between the 4th and 8th week after surgery (both P>0.05 (Bonferroni correction method)). Accordingly, LVEF gradually decreased ((73.7±8.4)%, (63.7±19.1)%, (53.7±14.6)% and (49.9±15.4)%; F=6.22, P=0.004). LVEDV (9.0(6.0, 21.0), (31.4±16.3), (32.9±17.4) and (36.4±17.5) ml; H=8.58, P=0.035)and LVESV ((3.8±3.2), (15.9±15.3), 12.0(10.0, 17.0)and (19.3±10.9) ml; H=10.51, P=0.015) gradually increased. SMS and STS continuously increased as well ( H values: 16.49, 13.33, P values: 0.001, 0.004). Conclusions:With the progression of coronary artery stenosis to occlusion, myocardial perfusion is gradually decreased, while the global and regional LV function, LV remodeling are gradually aggravated, and HM is gradually reduced. After the chronic coronary artery occlusion, myocardial perfusion has a trend to be improved and HM is gradually recovered.
4.The clinical value of 18F-FDG PET/CT dual-time-point imaging in diagnosing aortic graft infection
Wei DONG ; Tiantian MOU ; Jinghong XIA ; Jian JIAO ; Quan LI ; Mingkai YUN ; Hongzhi MI ; Junming ZHU ; Xiaoli ZHANG ; Xiang LI
Chinese Journal of Thoracic and Cardiovascular Surgery 2022;38(6):357-363
Objective:To explore the diagnostic value of 18F-deoxyglucose (FDG) PET/CT dual-time-point imaging (DTPI) in the diagnosis of aortic grafts infection (AGI). Methods:Forty-two patients with suspected AGI were prospectively recruited in this DTPI study from October 2014 to October 2021. There were 35(83%) males and 7 females, mean age (54±15) years old, range 22-79 years old. PET/CT image quality was scored as 5 grading scale. Semi-quantitative analysis of DTPI data was performed using maximum standardized uptake value (SUVmax) of suspected AGI lesions. The percentage of SUVmax change between initial and delayed images were recorded as retention index (RI). Management of Aortic Graft Infection Collaboration (MAGIC) criteria were used as the diagnostic reference criteria for AGI.Results:According to the MAGIC criteria, 27 patients (64%) were positive for AGI, and 15 patients (36%) were negative. The mean RI of AGI was higher than that of non-AGI ones[(26.7±18.9)% vs. (6.4 ±18.8)%, P<0.01]. The sensitivity, specificity, and accuracy of initial SUVmax ≥6 with the presence of AGI was 88.9%, 73.3%, and 83.3%, respectively. Delayed SUVmax ≥6 improved the sensitivity (96.3%) and accuracy (88.1%) for diagnosing AGI. DTPI with 15% increment as the optimal cut-off value of RI improved the specificity (93.3%) and accuracy (90.5%) for diagnosing AGI. Fifteen (56%, 15/27) AGI patients had improved image quality grading on the delayed images, leading to more accurately delineating the detailed extent of the infected aortic graft. Conclusion:18F-FDG PET/CT DTPI has better diagnostic performance for AGI than conventional Single-time-point PET/CT imaging by improving image quality as well as enhancing delineation of infected aortic graft extent.
5.Establishment of the normal reference values of left ventricular function parameters evaluated by CZT SPECT stress gated myocardial perfusion imaging in low-likelihood of stable coronary artery disease
Jingjing MENG ; Jian JIAO ; Xiaofen XIE ; Tiantian MOU ; Zhi CHANG ; Junqi LI ; Zhiyong SHI ; Yanlin WANG ; Shuang ZHANG ; Mingkai YUN ; Hongzhi MI ; Xiaoli ZHANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2023;43(3):144-149
Objective:To establish the normal reference value of left ventricular function parameters by cadmium-zinc-tellurium (CZT) SPECT stress gated myocardial perfusion imaging (G-MPI) in low-likelihood of stable coronary artery disease (SCAD).Methods:From March 2022 to August 2022, 348 consecutive SCAD patients (146 males, 202 females, age (58±10) years) who underwent exercise or pharmacological stress G-MPI (CZT SPECT) in Beijing Anzhen Hospital, Capital Medical University were retrospectively recruited. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV), and left ventricular ejection fraction (LVEF) were acquired using quantitative gated SPECT (QGS) analysis. EDV and ESV were corrected by body surface area (BSA) to obtain EDV index (EDVI) and ESV index (ESVI), respectively. Independent-sample t test, one-way analysis of variance and Mann-Whitney U test were used for data analysis. The influences of EDV, ESV, EDVI, ESVI and LVEF were analyzed by multiple regressions for linear models. Results:There were 314 patients with low-likelihood of SCAD (128 males, 186 females, age (58±10) years) and 34 normal controls (18 males, 16 females, age (55±10) years). There were no significant differences of basic clinical characteristics and left ventricular function parameters in different genders between 2 groups ( z values: from -1.74 to -0.02, t values: from -1.16 to 1.17, all P>0.05). Using the 95% CI as the cut-off value for left ventricular function parameters in patients with a low-likelihood of SCAD, the upper limits of EDV, ESV, EDVI and ESVI in females and males were 84 and 111 ml, 30 and 44 ml, 47 and 54 ml/m 2, 17 and 21 ml/m 2, respectively, and the lower limit of LVEF in females and males were 58% and 55%, respectively. In the low-likelihood of SCAD group, the EDV ((58±13) vs (77±17) ml) and ESV ((16±7) vs (26±9) ml) of females were smaller than those of males ( t values: 10.65, 10.35, both P<0.001), while LVEF of females was higher than that of males ((72±7)% vs (67±6)%; t=-6.23, P<0.001). However, there were no significant differences in left ventricular function parameters among different age groups with the same gender ( F values: 0.12-2.19, all P>0.05). Based on multiple regression for linear models, the primary predictors of EDV, ESV and LVEF were gender and weight ( β values: from -0.380 to 0.358, all P<0.05). Conclusions:Normal reference values of left ventricular function parameters are established by CZT SPECT stress G-MPI in low-likelihood of SCAD patients. Left ventricular EDV and ESV of females are smaller than those of males, while LVEF of females is higher than that of males. The influence of gender on left ventricular function parameters should be considered in clinical practice.
6.Ambient radiation of patients undergoing 18F-FDG PET/CT myocardial metabolism imaging
Xinyu HE ; Yingfei PI ; Xue CAO ; Yunyun WU ; Xiaoyan JIANG ; Mingkai YUN ; Xiaoli ZHANG ; Kuke DING
Chinese Journal of Radiological Health 2022;31(2):192-196
Objective To study the ambient radiation of patients undergoing 18F-FDG PET/CT myocardial metabolism imaging, and to provide data for protection of surrounding people against radiation. Methods A total of 33 patients were selected for 18F-FDG PET/CT myocardial metabolism imaging. Dose equivalent rate was measured at the height of patient chest, in different directions, at different time points and at different distances, to investigate the distribution of ambient radiation of the patient. Results At the same time point and distance, the dose equivalent rates at the left and right sides of the patient were lower than the front and back sides. The dose equivalent rate at 1 m in front of the patient was 13-21 μSv/h after 18F-FDG injection, and decreased to 5-14 μSv/h after PET/CT imaging, with a mean decrease of 46%. The ambient dose equivalent rate decreased exponentially with distance (10~300 cm), and the mean power was −1.2. Conclusion The ambient radiation of patients undergoing 18F-FDG PET/CT myocardial metabolism imaging was high after 18F-FDG injection, and the ambient dose equivalent rate decreased rapidly with time and distance. Our results suggest that patients undergoing myocardial metabolism imaging should avoid prolonged and close contact with other people on the day of examination.