1.Percutaneous intranodal lymphography: diagnostic and therapeutic effect for patients with chylous leakage
Tao GONG ; Jingui LI ; Jiawei CAO ; Xiaowu ZHANG ; He ZHAO ; Mingchen SANG ; Xiao LI ; Zhengqiang YANG
Chinese Journal of Radiology 2020;54(11):1056-1060
Objective:To evaluate the diagnostic and therapeutic effect of percutaneous intranodal lymphography in patient with chylous leakage.Methods:The clinical data of percutaneous intranodal lymphography in patients with chylous leakage from January 2019 to November 2019 in Cancer Hospital Chinese Academy of Medical Sciences were retrospectively analyzed. A total of 8 patients (5 males and 3 females, median age 64 years old) were enrolled. Four patients were iatrogenic chylothorax, 3 patients iatrogenic chyloperitoneum, and 1 patient chyloperitoneum with unknown cause. All 8 patients were received inguinal lymph nodes puncture under ultrasound guidance, and contrast agent iodinated oil was injected for lymphography. The procedure complications were recorded and the follow-up data were collected for efficacy assessment.Results:The percutaneous intranodal lymphography was successfully performed in all patients (8/8). The median amount of iodinated oil used was 17.5 ml; the median operation time was 88 min, without complications found during the procedure. The results of percutaneous intranodal lymphography was positive in 5/8 cases, of which chylothorax and chyloperitoneum was 4/4 and 1/4, respectively. Four cases with chylothorax showed contrast extravasation at different level of thoracic duct, and 1 case after pancreatic cancer resection showed contrast extravasation at L3-4 level. The chylous leakage was treated in 5 patients (5/8) during and resolved after percutaneous intranodal lymphography, with 3 chylothorax and 2 chyloperitoneum cases, respectively.Conclusion:Percutaneous intranodal lymphography is a safe and effective lymphography method for the diagnosis of chylous leakage, and also has application values in the treatment of chylous leakage.
2.An experimental study of a novel transjugular intrahepatic portosystemic shunt puncture set in animals
Yingen LUO ; Jingui LI ; Yawei LI ; Chao YANG ; Tianhao CONG ; Ruilin TIAN ; Hongcai YANG ; Yujie LI ; Mingchen SANG ; Xiao LI
Chinese Journal of Radiology 2023;57(11):1246-1251
Objective:To evaluate the feasibility and safety of a novel transjugular intrahepatic portosystemic shunt (TIPS) puncture set for transjugular intrahepatic portal puncture in swine.Methods:Thirteen domestic swine were randomly divided into experimental group ( n=7) and control group ( n=6) and received transjugular intrahepatic portal puncture with the novel puncture set and the R?sch-Uchida Transjugular Liver Access Set (RUPS-100), respectively. Three swines in each group were randomly selected and sacrificed immediately after the procedure and the rest were sacrificed 1 week later. The intraoperative technical success rate, puncture attempts, procedure time, fluoroscopy time, vital signs and occurrence of complications related to the procedure as well as the changes of liver and kidney function before, immediately after and 1 week after the procedure were compared between two groups. Independent sample t test, paired t test, Mann-Whitney U test, chi-square test or Fisher′s exact test were performed to compare the differences between groups. Results:The technical success rate was 100% for both groups. No significant difference in portal puncture attempts [2.0 (1.0, 5.0) vs. 2.0(1.0, 5.5), P>0.999], procedure time [(47.7±20.6) vs. (52.5±28.0)min, P=0.729] and fluoroscopy time [(725.1±489.2) vs. (763.7±562.4)s, P=0.897] was observed between two groups. In addition, no significant difference of the major liver and kidney function between two groups before, immediately after and 1 week after procedure ( P>0.05 at all time points). No significant difference of the major liver and kidney function change in two groups during perioperative period was identified (all P>0.05). Furthermore, no significant difference of non-target puncture occurrence was observed between two groups ( P>0.999). In the meantime, no significant difference of occurrence of small hematomas around hepatic hilar was discovered among swine sacrificed immediately after procedure between two groups ( P>0.999). No other major complications were identified in either group. Conclusion:The novel TIPS puncture set is feasible and safe to perform transjugular intrahepatic portal puncture in swine.