1.Program-controlled high-fi amplifier for EMG
Ming-Xin QIN ; Wei SONG ;
Chinese Medical Equipment Journal 1989;0(03):-
we have designed a program-controlled high-fi amplifier for EMG.Its gain can be controlled by computer.The program-contralled circuit is implemented with numerical control resistor.The amplifier can be used in automatically measuring EMG signals over 100?v.The circuit is characterized by easy de- sign,simple programing and convenient control.
2.Influence of complex aerobatics on serum gastrin level of pilots.
Gui Xi MA ; She Zhen QIN ; Ming Gao LI ; Lan Gen XU ; Xin Hua CHANG
Korean Journal of Aerospace and Environmental Medicine 1993;3(2):71-72
No abstract available.
Gastrins*
3.Study of effects of complex aerobatics on serum insulin, cortisol and angiotensin II.
Ming Gao LI ; She Zhen QIN ; Gui Xi MA ; Lang En XU ; Xin Hua ZHANG
Korean Journal of Aerospace and Environmental Medicine 1993;3(1):112-118
No abstract available.
Angiotensin II*
;
Angiotensins*
;
Hydrocortisone*
;
Insulin*
4.Analysis on prescription rules of treating senile dementia based on traditional Chinese medicine inheritance auxiliary systems.
Xin ZONG ; Xu-Ming JI ; Feng-Qin WEI ; Zuo-Rong SHI
China Journal of Chinese Materia Medica 2014;39(4):640-643
This is designed to analyze and summarize medication rules for treating senile dementia with Chinese medicine in CNKI according to the traditional Chinese medicine (TCM) inheritance auxiliary system. Collect documents in CNKI that account treating senile dementia with Chinese formula; filter and establish a formula database, and then to search for medication rules on the TCM inheritance auxiliary system. It is filtered that 104 formulas are used for treating senile dementia screening treat senile dementia, involving 147 kinds of Chinese medicine. Tonic medicine are most frequently used, followed by the medicine of activating blood circulation and resuscitating; medicine pair most used is Ligusticum chuanxiong Hort-Acorus tatarinowii, accounting for 27.9% of all formula. And then 8 core pairs and 4 new formulas are evolved. Analysis on formulas for treating senile dementia filtered form CNKI by TCM inheritance auxiliary system shows prescription is mainly tonifying, activating blood circulation and resuscitating, that reveals prescription rules, to provide a reference for clinical treatment.
Databases, Factual
;
Dementia
;
drug therapy
;
Drug Prescriptions
;
Drug Therapy, Combination
;
Drugs, Chinese Herbal
;
chemistry
;
therapeutic use
;
Humans
5.Effect of andrographolide on the mRNA expression of MexAB-OprM efflux pump of Pseudomonas aeruginosa PAOI strain
Hong-Tao LI ; Chun-Ming WU ; Hui-Min QIN ; Guo-Jun LI ; Jian-Xin SONG ;
Chinese Journal of Infectious Diseases 2001;0(06):-
Objective To develop a real-time polymerase chain reaction(PCR)system to determine transcriptional level of MexAB-OprM multidrug efflux pump gene and to investigate the impact of androgra- pholide on MexAB-OprM gene transcription in Pseudomonas aeruginosa.Methods The fragments of mexB gene of mexAB-oprM operon and 30S rRNA gene rpsL were amplified and cloned into two plas- mids respectively.These plasmids were used as external standards for real-time PCR.Real-time PCR was applied to measure the mRNA transcripition of mexB and rpsL gene in Pseudomonas aeruginosa growing in medium with different concentrations of andrographolide.Results The plasmids for standard curve were constructed successfully.The relative mexB mRNA expressions in 50,100,150 and 200?g/mL andrographolide were 0.04?0.03,0.06?0.07,0.09?0.03 and 0.04?0.03 respectively, which were significantly lower than that in the control(0.24?0.04,P0.05).Conclusion Andrographolide can reduce the transcriptional level of MexAB-OprM,which may he one mechanism for its anti-infection effect.
6.Comparison of anterior chamber depth and central corneal thickness measuring values between Sirius and Pentacam
Yan, LI ; Shi-ming, CHENG ; Xin, YANG ; Jin-hai, HUANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(3):262-265
Background Biometry of the anterior ocular segment parameter is very important for the diagnosis and treatment of glaucoma and ocular injury as well as measurement of intraocular lens(IOL).Objective This study was to compare the differences in the anterior chamber depth(ACD) and the central corneal thickness (CCT) between Sirius and Pentacam and evaluate the agreement of these two measurement methods.Methods The ACD and the CCT of 38 right eyes from 38 health volunteers aged 23- 32 years were measured with both Pentacam and Sirius.Three times of measurement were pedormed on each eye for each method to obtain the average values.The repeatability and agreement from each method were assessed as intraclass correlation coefficient( ICC ) and coefficient of variation(CV) and the agreement between these two methods were evaluated using Bland-Altman mode.ResultsThe mean ACD value was( 3.18±0.21 ) mm from Pentacam with the ICC 0.995 and CV 0.066.The mean ACD value from Sirius was (3.22 ±0.21 )mm with the ICC 0.996 and CV 0.065.The difference value in ACD between two methods was 0.04 mm,showing a significant difference( t =-6.225,P<0.05 ) and a positive correlation (r=0.977) between two methods.The 95% limit of agreement was( -0.04-0.13)mm within 1 standard difference (SD) of the mean value( ±0.21mm),which was acceptable for clinical measurement.The CCT was( 535±33 )μm from Pentacam with the ICC 0.994 and CV 0.062.The CCT was(537±36)pm from Sirius with the ICC 0.999 and CV 0.067.The difference value in the CCT between two methods was about 2 μm,presenting a in significant difference ( t =1.771,P>0.05 ) and positive correlation ( r =0.985 ).The 95 % limit of agreement was ( - 11.64-15.65 ) μm within 1 SD of the mean value( ±34.27 pm),which was acceptable for clinical measurement.ConclusionsSirius and Pentacam show good agreement in the measurement of ACD and CCT.The two methods offer an alternative choice for the biological measurement of the anterior ocular segment.
7.Comparison of axial length and anterior chamber depth measurements by IOLMaster, Axis- Ⅱ A-scan and ODM 1000A sonograph
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(11):1023-1026
Background Axial length and anterior chamber depth are important parameters for the calculation of diopter of intraocular lens ( IOL ). Objective This study was to investigate and compare the measuring outcomes of axial length and anterior chamber depth with IOLMaster,Axis- Ⅱ A-scan and ODM 1000A sonograph.Methods This a observational study.Axial length and anterior chamber depth were measured in 83 eyes of 48 patients with IOLMaster,Axis-Ⅱ A-scan and ODM 1000A sonograph by the same operator.The measuring results were compared among the three methods.Results The axial length were(25.79±0.85) mm,(25.72± 0.82 )mm and ( 26.00 ±0.83 )mm respectively with Axis- Ⅱ,ODM 1000A sonograph and IOLMaster.The difference between Axis-Ⅱ and DM 1000A sonograph was (0.07 ± 0.35 )mm without statistical difference between them (t=1.711,P =0.091 ).The difference of axial length between IOLMaster and DM 1000A sonograph was ( 0.27 ±0.29) mm with a statistical difference between them ( t =-8.570,P =0.000 ).The difference between IOLMaster and Axis- Ⅱ was (0.21 ±0.32 ) mm and showed a statistical difference ( t =- 5.931,P < 0.01 ).The positive correlations were found in the axial length values by the each other comparison among the three instruments( r=0.916,0.938,0.928,P<0.01 ).The anterior chamber depth values were ( 3.81 ±0.21 ) mm,( 3.84 ±0.25 ) mm and ( 3.83 ±0.18 )mm respectively with Axis-Ⅱ,0DM 1000A sonograph and IOLMaster.The difference of anterior chamber depth between Axis- Ⅱ and DM 1000A was (0.03 ±0.17 ) mm without statistical difference between them ( t =- 1.324,P =0.189 ).The difference in the anterior chamber depth between IOLMaster and DM 1000A was (0.01 ±0.15 ) mm and that between IOLMaster and Axis-Ⅱ was( 0.01 ±0.12)mm without any statistical differences among them (t =0.815,P=0.417 ;t=-0.900,P=0.371 ).The high correlation between anterior chamber depth measurements were found by the each other comparison in the three instruments ( r =0.735,0.813,0.823,P < 0.01 ).Conclusions ODM 1000A sonograph can provide precise axial length and anterior chamber depth values.However,ODM 1000Asonograph can not substitute for IOLMaster in the measurement of the anterior chamber depth and axial length.
8.Comparison among different noncontact specular microscopes for the detection of corneal endothelial cell density
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Rong-rong, GAO ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(2):150-154
Background Clinical research showed that the corneal endothelial cell density value from different corneal specula microscopies exist diversity.The relevant literature of SP02,Tomey EM-3000 and SP3000P is still seldom up to now. Objective This research was to assess the repeatability of endothelial cell density measurements by SP02,Tomey EM-3000 and SP3000P respectively and the agreement among 3 kinds of endothelial microscopes.MethodsFifty-four healthy volunteers with the age 17-38 years old were included this research.The written informed consent was obtained from each subject before examination.The corneal endothelial cell densities in the right eyes were analyzed with SP02,Tomey EM-3000 and SP3000P respectively for 3 times under the automatic mode,and the analytical procedure of SP3000P measurement were divided into automatic mode SP3000P (A) and manual correction modes SP3000P( M).The repeatability of each specula microscopy was analyzed by calculating the intraclass correlation coefficients (ICC) and coefficient of variation ( CV ),and the 95% confidence intervals and plotting Bland-Altman graphs were used to analyze the agreement among these methods.ResultsThe mean corneal endothelial cell densities in the population <24 years were significantly higher than the ones ≥ 24 years (t =3.692,P<0.05 ),but no statistical difference was found between different gender ( t =0.335,P =0.739 ).The mean corneal endothelial cell densities were ( 3058 ± 260 ),( 2954 ± 229 ),( 2668 ± 258 ),( 2734 ± 268 ) cell/mm2 ; the ICCs were 0.957,0.940,0.972 and 0.972 and the CV were 0.063,0.061,0.056,0.058 for SP02,Tomey EM-3000,SP3000P (A) and SP3000P ( M ) respectively.The 95% confidence intervals were ( - 100.8 - 306.8 ),( 162.6 - 617.4 ),( 109.9-494.1 ) and ( -0.6 - 132.6 ) cell/mm2 for between SP02 and Tomey EM-3000,SP3000P ( A ) and SP02,SP3000P(A) and Tomey EM-3000,SP3000P(A) and SP 3000P(M) respectively.ConclusionsSP02,Tomey EM-3000 and SP3000P(A) have good repeatability in the measurement of corneal endothelial cell density,however the outcome is different.Therefore,it is not interchangeable for the detection of corneal endothelial cell density.The differences of corneal endothelial cell density obtained from these instruments shall be paid high attention for their differences.SP3000P(A) and SP3000P(M) can be used interehangeably and SP3000P(A) is a preferable choice due to its convenience and quickness.
9.Screening of differential serum proteins in patients with hepatic injury resulting from coal-burning type of arsenism
Ru-jia, XIE ; Bing, HAN ; Xin-hua, LUO ; Jun, WU ; Ming-liang, CHENG ; Qin, YANG
Chinese Journal of Endemiology 2010;29(6):604-607
Objective To identify the differential serum proteins in patients with hepatic injury resulting from coal-burning type of arsenism. Methods Six serum samples were collected from patients with liver injury resulting from coal-burning type of arsenism and healthy subjects(control gruop) in endemic arsenism area. Twodimensional gel electrophoresis(2-DE) was performed to separate serum proteins, after silver staining, the differential expression of proteins were analyzed and then identified by matrix-assisted laser desorption/ionization time of flight mass spectrometry(MALDI-TOF-MS). Results The 2-DE map of serum protein patterns of patients and normal control were established successfully. The results showed that there were an average of (824 ± 31 ) spots and (782 ± 42) spots on 2-DE matching of the patients and control groups and the matching rate was 94.9%(782/824). From these two groups 49 differential protein spots were identified, of which over 3 times the difference in the expression of 30 protein spots were singled out and MALDI-TOF-MS analysis was carried out. Ten proteins were identified. Upregulated expression was observed in alpha-2-macroglobulin, B-cell receptor-associated protein, keratin 1,apolipoprotein A-I, and down-regulated expression was observed in haptoglobin, α2-heremans-schimid-glycoprotein,mitogen-activated protein kinase 4, zinc finger protein 323, ZAP-70 and SP40 in the patient group. Conclusions The well-resolved and reproducible 2-DE serum patterns of patients are established and some differentially expressed proteins are characterized. Whether these proteins of differential expression are serum markers for liver injury resulting from coal-burning type of arsenism need to be further verified.
10.Correlation between G-Protein ?3 Subunit Gene C825T Site Polymorphism and Obesity
xiao-ming, LOU ; xin-qiang, ZHU ; jian-fen, QIN ; gang-qiang, DING
Journal of Shanghai Jiaotong University(Medical Science) 2006;0(08):-
Objective To establish a method for rapidly detecting the G-protein ?3 subunit (GNB3) 825 site single nucleotide polymorphism (SNP) and to analyse the relationship between GNB3 825 site gene SNP and obesity. Methods The real-time fluorescent PCR was employed to analyse the GNB3 825 site gene SNP of 420 samples from 21 provinces and the the frequencies of genotypes were compared with those detected by gene sequencing. GNB3 825 site genotype, body weight, body mass index (BMI) and fat content were examined from 207 subjects and the correlation between GNB3 825 site gene SNP and obesity was analysed. Results The result by real-time fluorescent PCR showed that the frequencies of 825T and 825C haploid were 46.90% and 53.10%, respectively, and the frequencies of 825TT, 825TC and 825CC genotype were 22.38%, 51.42% and 28.10%, respectively, with no other genotype detected, which was consistent with the result by gene sequencing. BMI and fat content were significantly higher in subjects with GNB3 825TT than in subjects with other genotypes. Body weight was much higher in subjects with GNB3 825TT genotype than in subjects with 825CC genotype, but not significantly different with 825CT genotype. Conclusion A new rapid method for the detection of GNB3 825 site SNP has been successfully established. There existed significant correlation between GNB3 825TT genotype and obesity.