1.Progress on suxamethonium chloride analysis.
Ming-Zhe JIANG ; Xiang-Wei CHENG ; Jian-Xin CHU
Journal of Forensic Medicine 2013;29(6):451-453
Abstract: Suxamethonium chloride is a depolarizing muscle relaxant used in general anesthesia. In overdose, it causes adverse reactions such as bradycardia, arrhythmia, cardiac arrest, and death. The article reviews the progress on testing methods of suxamethonium chloride such as infrared spectroscopy, chemical color reaction, chemical titration, enzyme electrode, chromatography and mass spectrometry.
Anesthesia, General
;
Arrhythmias, Cardiac/chemically induced*
;
Biosensing Techniques
;
Bradycardia/chemically induced*
;
Chromatography
;
Drug Overdose
;
Heart Arrest/chemically induced*
;
Humans
;
Mass Spectrometry
;
Neuromuscular Depolarizing Agents/analysis*
;
Spectrophotometry, Infrared
;
Succinylcholine/analysis*
2.Distribution laws of 5 compounds in rhizome and root of Polygonum cuspidate.
Yao-wut LIU ; Jun WANG ; Shan-shan CHU ; Ming-en CHENG ; Cheng-wu FANG
China Journal of Chinese Materia Medica 2015;40(24):4834-4839
To understand the distribution and accumulation rules of polydatin, resveratrol, anthraglycoside B, emodin and physicion in different tissue structure of rhizome and root of Polygonum cospidatum, the content of 5 active compounds were analyzed simultaneously by HPLC, based on plant anatomy and histochemistry. The rhizome and root consist of different tissues, with an increased diameter, the proportions of the secondary xylem and phloem have increased. Resveratrol and polydatin mainly distributed in the pith, the secondary phloem and periderm of rhizome, and the secondary phloem and periderm of the root, while emodin and anthraglycoside B concentrated in the secondary structure and pith of rhizome mostly. In different thickness of the measured samples, the total contents of 5 compounds were correspondingly higher in thinner rhizome and root than those in the coarse ones.
Plant Roots
;
chemistry
;
Polygonum
;
chemistry
;
Rhizome
;
chemistry
3.Evaluating the Protective Effectiveness of Rubber Glove Materials Against Organic Solvents Upon Repeated Exposure and Decontamination
Li-Wen LIU ; Cheng-Ping CHANG ; Yu-Wen LIN ; Wei-Ming CHU
Safety and Health at Work 2024;15(2):228-235
Background:
Glove reuse poses risks, as chemicals can persist even after cleaning. Decontamination methods like thermal aeration, recommended by US OSHA, vary in effectiveness. Some studies show promising results, while others emphasize the importance of considering both permeation and tensile strength changes. This research advocates for informed glove reuse, emphasizing optimal thermal aeration temperatures and providing evidence to guide users in maintaining protection efficiency.
Methods:
The investigation evaluated Neoprene and Nitrile gloves (22 mils). Permeation tests with toluene and acetone adhered to American Society for Testing Materials (ASTM) F739 standards. Decontamination optimization involved aeration at various temperatures. The experiment proceeded with a maximum of 22 re-exposure cycles. Tensile strength and elongation were assessed following ASTM D 412 protocols. Breakthrough time differences were statistically analyzed using t-test and ANOVA.
Results:
At room temperature, glove residuals decreased, and standardized breakthrough time (SBT)2 was significantly lower than SBT1, indicating reduced protection. Higher temperature decontamination accelerated residual removal, with ΔSBT (SBT2/SBT1) exceeding 100%, signifying restored protection. Tensile tests showed stable neoprene properties postdecontamination. Results underscore thermal aeration's efficacy for gloves reuse, emphasizing temperature's pivotal role. Findings recommend meticulous management strategies, especially post-breakthrough, to uphold glove-protective performance.
Conclusions
Thermal aeration at 100°C for 1 hour proves effective, restoring protection without compromising glove strength. The study, covering twenty cycles, suggests safe glove reuse with proper decontamination, reducing costs significantly. However, limitations in chemical-glove combinations and exclusive focus on specific gloves caution against broad generalization. The absence of regulatory directives on glove reuse highlight the importance of informed selection and rigorous decontamination validation for workplace safety practices.
4.Idiopathic airway-centered interstitial fibrosis: report of two cases.
Xiang-hua YI ; Hai-qing CHU ; Xiao-ming CHENG ; Ben-fang LUO ; Hui-ping LI
Chinese Medical Journal 2007;120(9):847-850
Adult
;
Diagnosis, Differential
;
Humans
;
Lung
;
pathology
;
Lung Diseases, Interstitial
;
diagnosis
;
drug therapy
;
pathology
;
Male
;
Middle Aged
5.Hypoglycemia Revisited in the Acute Care Setting.
Shih Hung TSAI ; Yen Yue LIN ; Chin Wang HSU ; Chien Sheng CHENG ; Der Ming CHU
Yonsei Medical Journal 2011;52(6):898-908
Hypoglycemia is a common finding in both daily clinical practice and acute care settings. The causes of severe hypoglycemia (SH) are multi-factorial and the major etiologies are iatrogenic, infectious diseases with sepsis and tumor or autoimmune diseases. With the advent of aggressive lowering of HbA1c values to achieve optimal glycemic control, patients are at increased risk of hypoglycemic episodes. Iatrogenic hypoglycemia can cause recurrent morbidity, sometime irreversible neurologic complications and even death, and further preclude maintenance of euglycemia over a lifetime of diabetes. Recent studies have shown that hypoglycemia is associated with adverse outcomes in many acute illnesses. In addition, hypoglycemia is associated with increased mortality among elderly and non-diabetic hospitalized patients. Clinicians should have high clinical suspicion of subtle symptoms of hypoglycemia and provide prompt treatment. Clinicians should know that hypoglycemia is associated with considerable adverse outcomes in many acute critical illnesses. In order to reduce hypoglycemia-associated morbidity and mortality, timely health education programs and close monitoring should be applied to those diabetic patients presenting to the Emergency Department with SH. ED disposition strategies should be further validated and justified to achieve balance between the benefits of euglycemia and the risks of SH. We discuss relevant issues regarding hypoglycemia in emergency and critical care settings.
Diabetes Mellitus/drug therapy
;
Humans
;
Hypoglycemia/blood/*chemically induced/*complications/epidemiology
;
Hypoglycemic Agents/adverse effects/therapeutic use
;
Insulin/adverse effects/therapeutic use
6.Novel application of Influenza A virus-inoculated chorioallantoic membrane to characterize a NP-specific monoclonal antibody for immunohistochemistry assaying
Yang Chang TU ; Kuang Yu CHEN ; Chung Kung CHEN ; Ming Chu CHENG ; Shu Hwae LEE ; Ivan Chen CHENG
Journal of Veterinary Science 2019;20(1):51-57
Monoclonal antibodies (MAbs) are widely applied in disease diagnoses. Herein, we report a MAb, WF-4, against Influenza A virus nucleoprotein (NP), its broad response with Influenza A virus, and its application in an immunohistochemistry (IHC) assay. WF-4 was screened by immunofluorescence assay (IFA). The results showed that its reactivity with baculovirus-expressed full-length recombinant NP (rNP) in Western blot (WB), indicating its IHC applicability. Fifteen Influenza A virus (reference subtypes H1 to H15) infected chicken embryonated chorioallantoic membranes (CAM), fixed by formalin, were all detectable in the WF-4-based IHC assay. Also, the reactivity of the IHC test with NP from experimentally inoculated H6N1 and from all recent outbreaks of H5 subtype avian Influenza A virus (AIV) field cases in Taiwan showed positive results. Our data indicate that CAM, a by-product of Influenza A virus preparation, is helpful for Influenza A virus-specific MAb characterization, and that the WF-4 MAb recognizes conserved and linear epitopes of Influenza A virus NP. Therefore, WF-4 is capable of detecting NP antigens via IHC and may be suitable for developing various tests for diagnosis of Influenza A virus and, especially, AIV infection.
Animals
;
Antibodies, Monoclonal
;
Blotting, Western
;
Chickens
;
Chorioallantoic Membrane
;
Diagnosis
;
Disease Outbreaks
;
Epitopes
;
Fluorescent Antibody Technique
;
Formaldehyde
;
Immunohistochemistry
;
Influenza A virus
;
Influenza in Birds
;
Influenza, Human
;
Nucleoproteins
;
Taiwan
7.Evaluation of whole body MRI and diffusion-weighted MRI in detecting intranodal lesions in patients with lymphoma.
Zhen LI ; Dao-Yu HU ; Li-Ming XIA ; Ding-Yi FENG ; Li PENG ; Cheng-Yuan WANG ; Qian CHU
Chinese Journal of Oncology 2008;30(9):695-698
OBJECTIVETo evaluate the whole body MRI and diffusion-weighted MRI in detecting intranodal lesions in patients with lymphoma.
METHODSWhole body MRI and diffusion-weighted MRI (DWI) were performed in 23 patients with histologically proven lymphoma. A conventional coronal MRI scan from head to inguinal groove was done for whole body scanning. In the DWI, axial MRI scans were performed after segmentation based on SENSE technique, and all images were merged into whole body image reconstruction by software.
RESULTS417 lymph nodes were detected by MRI in the 23 patients. The overall positive rate of whole body MRI and DWI was 79.1% and 89.7%, respectively. It was 70.9% versus 85.2% and 79.4% versus 90.1% for the lymph nodes of < 2 cm and 2-3 cm in diameter, with a significant difference between the two methods (P < 0.01). However, it was 94.7% versus 97.9% for the lymph nodes of > 3 cm in diameter, not significantly different between the two methods (P > 0.05). Both methods had similar sensitivity in detecting the lymph nodes in the neck, supraclavicular and infraclavicular fossae, mediastinum and axillary fossa. However, the positive rate of whole body MRI was 51.2%, 43.8% and 52.2%, significantly less sensitive than 83.7%, 71.9% and 87.0%, respectively, by DWI in detecting the lymph nodes in the retroperitoneal space, pelvic cavity and inguinal groove (all P < 0.01).
CONCLUSIONBoth whole body MRI and diffusion-weighted MRI have a relative high sensitivity in detecting intranodal lesions for patients with lymphoma, showing a certain value in clinical application.
Adolescent ; Adult ; Aged ; Diffusion Magnetic Resonance Imaging ; methods ; Female ; Humans ; Lymph Nodes ; pathology ; Lymphoma ; diagnosis ; pathology ; Magnetic Resonance Imaging ; methods ; Male ; Middle Aged ; Neoplasm Staging ; Whole Body Imaging ; methods ; Young Adult
8.Ureteroscopic lithotripsy using holmium laser for 187 patients with proximal ureteral stones.
Ding-Yi LIU ; Hong-Chao HE ; Jian WANG ; Qi TANG ; Yan-Feng ZHOU ; Ming-Wei WANG ; Cheng-Long CHU ; Chong-Yu ZHANG ; Yu ZHU ; Wen-Long ZHOU ; Zhou-Jun SHEN
Chinese Medical Journal 2012;125(9):1542-1546
BACKGROUNDImproving the success rate of ureteroscopic lithotripsy for proximal ureteral stones is the hot issue in this field. Here we reported our experience on the treatment of proximal ureteral stones.
METHODSFrom 2005 to 2010, 187 consecutive patients with proximal ureteral stones who underwent ureteroscopic lithotripsy were enrolled. The initial 52 patients treated by semi-rigid ureteroscope alone were classified as group 1. The subsequent 135 patients treated by semi-rigid ureteroscope with the aid of stone basket and flexible ureteroscope were classified as group 2.
RESULTSIn group 1, the overall stone-free rate was 67.3%. By a single procedure of ureteroscopic lithotripsy using a semi-rigid instrument, patients with ureteral stones below the 4th lumbar vertebra level achieved 91.7% stone-free rate, which was only 50% in patients with stones above the 4th lumbar vertebra level. Conversion to open surgery occurred in two patients since ureteral perforation was observed. In group 2, the stone-free rate achieved 93.2% with the aid of an N-Trap basket, which was significantly higher than that of patients without the aid of the basket (51.6%). Flexible ureteroscope was subsequently used in patients with fragment migration, thus making the overall success rate in group 2 increases to 97.0%.
CONCLUSIONSUreteroscopic lithotripsy is a safe and efficacious treatment for proximal ureteral stones. A single procedure of ureteroscopic lithotripsy using semi-rigid ureteroscope could achieve a satisfactory stone-free rate in patients with proximal ureteral stones below the 4th lumbar vertebra level. However, patients with ureteral stones above the 4th lumbar vertebra level experienced higher stone-migration rate, which would decrease the success rate. Fortunately, the stone-free state could possibly be achieved with the aid of an N-trap basket and flexible ureteroscope.
Adolescent ; Adult ; Aged ; Humans ; Lasers, Solid-State ; therapeutic use ; Lithotripsy, Laser ; methods ; Middle Aged ; Ureteral Calculi ; therapy ; Young Adult
9.Development of Dipolar Proton Transfer Reaction Mass Spectrometer for Real-time Monitoring of Volatile Organic Compounds in Ambient Air
Qiang-Ling ZHANG ; Xue ZOU ; Qu LIANG ; Ya-Ting ZHANG ; Ming-Jian YI ; Hong-Mei WANG ; Chao-Qun HUANG ; Cheng-Yin SHEN ; Yan-Nan CHU
Chinese Journal of Analytical Chemistry 2018;46(4):471-478
Volatile organic compounds (VOCs) in ambient air can participate in photochemical reactions, which lead to the generation of secondary pollutants such as ozone and aerosol. So real-time and accurate monitoring of atmospheric VOCs plays an important role in the study of the causes of air pollution. On the basis of proton transfer reaction mass spectrometry (PTR-MS) research, a novel dipolar proton transfer reaction mass spectrometer (DP-PTR-MS) for real-time and on-line monitoring atmospheric VOCs was developed. Compared with the conventional PTR-MS with one kind of reagent ion H3O+, DP-PTR-MS had three kinds of reagent ions H3O+, OH-, (CH)2COH+, which could be switched according to the actual detection need. So DP-PTR-MS can improve the qualitative ability and expand the detection range effectively. The reagent ion H3O+can be used for detecting VOCs whose proton affinities are greater than that of H2O. The reagent ion OH-can be used to identify VOCs cooperating with the reagent ion H3O+,and can also be used for detecting some inorganic substances such as CO2. The reagent ion (CH3)2COH+can be used for accurately detecting NH3under interference elimination circumstances. The limit of detection (LOD) and sensitivity of DP-PTR-MS were measured by using six kinds of standard gases. The results showed that the LOD for detecting toluene was 7×10-12(V/V) and the sensitivity for detecting ammonia has reached 126 cps/10-9 (V/V). The ambient air in Hefei city was on-line and real-time monitored for continuous 78 hours with DP-PTR-MS. The results showed that the newly developed DP-PTR-MS could be used for long-term and real-time monitoring atmospheric VOCs with the concentration of 10-12(V/V) level. DP-PTR-MS is an important tool for the study of the causes of atmospheric pollution and the monitoring of trace VOCs emissions.
10.Preparation and bioIogicaI properties of TiN/Ag composite coating on pure titanium surface
Ming MA ; Rong-Xin WAN ; Xiao-Fei LV ; Shan-Shan CHU ; Li-Jun LI ; Han-Qing GU ; Cheng PENG
Chinese Journal of Tissue Engineering Research 2018;22(2):189-195
BACKGROUND: It is of vital importance to fabricate an interface on the titanium implant surface which can promote early cell adhesion, proliferation, and differentiation, and exert better antibacterial effects with no cytotoxicity. OBJECTIVE: To prepare a TiN/Ag composite coating on the surface of pure titanium implant, and to explore its antibacterial properties and effects on MC3T3-E1 biobehaviors. METHODS: Acid etching blasting and multi-arc ion plating were adopted to prepare TiN/Ag composite coating on the smooth surface of pure titanium. Then, MC3T3-E1 cells that grew well were inoculated onto pure titanium plate, sandblasted and acid-etched titanium plate, and TiN/Ag-coated titanium plate. Twenty-four hours later, cell adhesion and viability were observed under confocal laser scanning microscope, and cell morphology was observed under scanning electron microscope. Cell counting kit-8 was used to detect cell proliferation and cytotoxicity at 24,48,72 hours after inoculation.In addition,Staphylococus aureus solution was dropped onto the smooth titanium plated, acid-etched and sandblasted titanium and TiN/Ag-coated titanium plate, and the growth of bacteria was observed by the laser confocal scanning microscope at 16 hours. RESULTS AND CONCLUSION: Under the confocal laser scanning microscope, spindle cells with bipolar or three poles were observed on the smooth titanium surface, and there was less F-actin and filopodia expression; cells on the TiN/Ag-coated titanium surface and sandblasted and acid-etched titanium surface were scattered with a large amount of interconnected filopodia that were fully stretched and adhered to the titanium surface, highly expressed F-actin was detected, and actin fibers were thickened. Under the scanning electron microscope, the cells on the smooth titanium surface were not fully adhered and stretched, and those on the TiN/Ag-coated titanium surface or the sandblasted and acid-etched titanium surface exhibited better adhesion and extension. Findings from the cell counting kit-8 showed that after 72 hours of inoculation,the cells on the smooth titanium surface grew well,with cytotoxicity level 1.In addition,Staphylococus aureus grew well on the smooth titanium surface under the confocal laser scanning microscope,while a large amount of Staphylococus aureus died on the TiN/Ag-coated titanium surface or on the sandblasted and acid-etched titanium surface. These findings indicated that TiN/Ag coating has good biocompatibility and antibacterial properties.