1.Detection system of multi-channel physiological parameters of uterine cavity based on USB interface
Chinese Medical Equipment Journal 2004;0(09):-
USB interface chip PDIUSBD12 and Microchip's single chip processor PIC16F877 are applied to achieving computerized multi-channel data acquisition, and then a detection system of multi-channel physiological parameters of uterine cavity is designed on the basis of the above-mentioned. Being plug-and-play, real-time and general-purpose, this system can meet the requirement of medical research on the relationship between these parameters and diseases of uterine cavity.
2.Liver pathology in China: retrospect and prospect.
Chinese Journal of Pathology 2005;34(8):493-496
3.Markers of hepatic ischemia-reperfusion injury:a recent progress
Chun-Yan XIA ; Wen-Ming CONG ;
Academic Journal of Second Military Medical University 1985;0(06):-
Hepatic ischemia-reperfusion injury(IRI)is a critical problem of liver surgery,especially when comes to liver transplantation.Presently.there are no effective measures for diagnosis,prevention and therapy of IRI,as the mechanisms of IRI still remain unclear.This review summarizes several new hepatic ischemia-reperfusion markers related to cell signal transduetion pathway.including transcription factor STAT,HIF-1 and PPARs,transmission factor MAPK,membrane receptor TLR4 and PARs.and iNOS.Animal studies have indicated that IRI was ameliorated by activating or blockading these markers,which might serve as targets for diagnosis,prevention and therapy of IRI.
4.More emphasis on pathobiological behavior of hepatic tumors.
Chinese Journal of Surgery 2010;48(15):1121-1124
5.Manipulative reduction and percutaneous pin fixation for the treatment of severely displaced distal tibial fractures in children.
Cong-cong YE ; You-ming ZHA ; Wei-jun GUO ; Chen LIN ; Xiang YANG
China Journal of Orthopaedics and Traumatology 2014;27(8):691-693
OBJECTIVETo study the therapeutic efficacy of manipulative reduction and percutaneous pin fixation for the treatment of severely displaced distal tibial fractures in children.
METHODSFrom May 2009 to December 2012,56 children with severely displaced distal tibial fractures were analyzed, who had been treated with manipulative reduction and percutaneous pin fixation. Preoperative fractures were confirmed as severely displaced fractures by X-ray apparatus. There were 33 boys and 23 girls,ranging in age from 3 to 14 years, with an average of 10.1 years. All the fractures were closed without vascular or nerve injuries. According to the bone fracture type, under C-arm fluoroscopy, functional reduction was achieved by manipulative reduction. The fractures were fixed with percutaneous pins. Postoperative X-ray confirmed the functional reduction. Follow-up indexes were recorded: intra-operative and postoperative complications,postoperative radiographic examination, lower extremity length and range of ankle motion. Ankle score system of Teeny was used to evaluate ankle function.
RESULTSAll the patients were followed up, and the duration ranged from 3 to 46 months, with an average duration of 19.4 months. According to the Teeny score standard, 35 patients got an excellent result, 7 good and 3 fair. Pin track reaction was found in 4 cases. The X-ray showed all the fractures healed without shortening deformity or epiphyseal arrest at early stage. All the patients could participate in the normal physical activities, having a normal range of motion and excellent strength of the ankle joint.
CONCLUSIONThe method of manipulative reduction and percutaneous pin fixation is a safe and convenient treatment for severely displaced distal tibial fractures in children. It has several advantages as follow: micro-trauma, tiny tissue damage, firm fixation, and the patients can exercise the function of ankle early, suggesting that it is an effective treatment method.
Adolescent ; Adult ; Bone Nails ; Child ; Child, Preschool ; Combined Modality Therapy ; Female ; Fracture Fixation, Internal ; methods ; Humans ; Male ; Manipulation, Orthopedic ; methods ; Middle Aged ; Tibial Fractures ; surgery
6.Treatment type C fracture of the distal radius with locking compression plate and external fixators.
Xiang YANG ; You-ming ZHAO ; Lin CHEN ; Cong-cong YE ; Wei-jun GUO ; Bo WANG
China Journal of Orthopaedics and Traumatology 2013;26(12):997-1001
OBJECTIVETo compare efficacy of unilateral external fixators and locking compression plates in treating type C fractures of the distal radius.
METHODSFrom January 2009 to June 2010, 76 patients with distal radius fracture were treated with LCP and external fixators, 54 patients were followed up. Among them, 29 cases were male and 25 cases were female with an average age of 45.31 (ranged, 24 to 68) years old. There were 29 patients in LCP group. According to AO classification, 8 cases were type C1, 7 cases were type C2 and 14 cases were type C3. There were 25 cases in external fixators group. According to AO classification, 6 cases were type C1, 8 cases were type C2 and 11 cases were type C3. Radial height, volar tilt and radial inclination were compared, advanced Gartland-Werley scoring were used to assessed wrist joint function after 6 and 12 months' following up.
RESULTSTwo cases were suffered from nail infection in external fixators group. Fifty-four patients were followed up from 12 to 24 months with an average of 21.3 months. Radial height was (9.60 +/- 0.72) mm, volar tilt was (9.55 +/- 0.80) degrees and radial inclination was (21.40 +/- 0.78) degrees in LCP group,while those were (9.40 +/- 0.70) mm, (9.47 +/- 0.71) degrees and (21.20 +/- 0.73) degrees in external fixtors group, and with no statistical significance (P>0.05). Advanced Gartland-Werley score after 6 months' following up was 3.31 +/- 1.17 in LCP group, 5.56 +/- 1.58 in external fixtors group, and with significant difference (t=-5.99,P<0.05); after 12 months' following up, advanced Gartland-Werley score was respectively 2.66 +/- 1.01 and 3.08 +/- 1.00, but with no statistical meaning (t=-1.55, P>0.05).
CONCLUSIONLCP and external fixtors can receive good curative effects in treating type C distal radius fracture, and LCP can obtain obviously short-term efficacy, while there is no significant difference between two groups in long-term results. For serious distal radius comminuted fracture which unable to plate internal fixation, external fixators is a better choice.
Adult ; Aged ; Bone Plates ; External Fixators ; Female ; Fracture Fixation, Internal ; Fractures, Comminuted ; surgery ; Humans ; Male ; Middle Aged ; Radius ; surgery ; Radius Fractures ; surgery ; Treatment Outcome ; Young Adult
7.The indirect diagnosis for lactase deficiency
cong-min, ZHAO ; wei-ming, LI ; ying, YANG
Journal of Applied Clinical Pediatrics 1986;0(01):-
0.1), there is not significant difference between them. Comparing with blood method, the sensitivity and specificity of urine method are 94 .1 % and 91. 6 % respectively.Conclusions To determine the B-gal and U-gal, O-toluidine method can be regarded as an indirect diagnostic method of LD.
8.The application of case-based learning with multimedia teaching in the clinical teaching of pediatric surgery
Xiangyang QU ; Ming LI ; Cong LUO ; Yujiang CAO
Chinese Journal of Medical Education Research 2014;13(5):525-528
Objective To explore the application of case based learning(CBL)combined with multimedia teaching in the clinical pediatric surgery.Methods 144 five-year program students of Pediatrics in grade 2009 were randomly and evenly divided into the experimental group using CBL with multimedia teaching,and the control group using multimedia teaching mode.After the end of the course the students of the two groups took clinical teaching knowledge test.The evaluation scores were shown by mean ± standard deviation and comparison was made between the two groups with t test.At the same time,teaching satisfaction survey was conducted among the students of the experimental group.Results The usual results,the theoretical scores and total scores of the students in the experimental group were higher than those of the control group students in the operation skills,clinical thinking,and there was statistically significant difference in P<0.01.(P=0.003,P=0.002,P=0.008,P=0.009,P=0.008).The questionnaire survey shows that compared with traditional multimedia teaching,CBL combined with multimedia teaching can preferably culture students' various abilities and is beneficial to learning.Condusion The use of CBL combined with multimedia teaching can affirmatively improve the clinical teaching effect in the clinical pediatric surgery,and it deserves to be generalized in the future teaching.
9.Improving doctor-patient relationship, enhancing the oral cavity medical service effect
Ming-cong YANG ; Xiao-ping FAN ; Xue-rong XIANG
Chinese Journal of Medical Education Research 2011;10(7):851-853
While the medicine pattern of biomedicine turn to biological-psychology-society, the medical trouble communication becomes more and more important in the medical service. Good medical trouble communication ability is the essential condition of doctor. As oral cavity clinicians, only by gasping the principle of communication can we appropriately utilize some skills of communication exchange,establish the good medical trouble relations with the patient and achieve the good treatment result finally.
10.Primary Analysis of Biochemical Characters of a Selenium-containing Protein From Se-enriched Ganoderma lucidum(Se-GL-P)
Ming DU ; Xiaosong HU ; Cong WANG ; Guanghua ZHAO
Progress in Biochemistry and Biophysics 2006;0(03):-
As a basic work of illustrating the relationship between the structure and function of a kind of protein purified from Se-enriched Ganoderma lucidum (Se-GL-P), the primary biochemical characters of Se-GL-P were characterized. Molecular mass was determined by two methods of sodium dodecyl sulfate polyacrylamide gel electrophoresis and size exclusion chromatogram. Amino acids composition, isoelectric point, peptide mass fingerprint, and the sequence of N terminal amino acids were determined by high performance liquid chromatography, capillary isoelectric focusing method, in-gel digestion, and Edman digestion method respectively. Results showed that, the Mr of Se-GL-P was 36 600, pI=4.01, and the sequence of N-terminal amino acids was DINGGGATLPQKLYLTPDVL. A conclusion was drawn that Se-GL-P was a kind of new selenium-containing protein, and it was one member of DING protein family.