1.Radiographic evaluation of the maxillary sinus prior to dental implant therapy: A comparison between two-dimensional and three-dimensional radiographic imaging.
Aditya TADINADA ; Karen FUNG ; Sejal THACKER ; Mina MAHDIAN ; Aniket JADHAV ; Gian Pietro SCHINCAGLIA
Imaging Science in Dentistry 2015;45(3):169-174
PURPOSE: This study was performed to evaluate the diagnostic efficacy of panoramic radiography and cone-beam computed tomography (CBCT) in detecting sinus pathology. MATERIALS AND METHODS: This study was based on a retrospective evaluation of patients who had undergone both a panoramic radiograph and a CBCT exam. A total of 100 maxillary sinuses were evaluated. Four examiners with various levels of expertise evaluated the images using a five-point scoring system. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic efficacy of the two modalities. The image analysis was repeated twice, with at least two weeks between the evaluation sessions. Interobserver reliability was assessed using Cronbach's alpha, and intraobserver reliability was assessed using Cohen's kappa. RESULTS: Maxillary sinus pathology was detected in 72% of the patients. High interobserver and intraobserver reliability were observed for both imaging modalities and among the four examiners. Statistical analyses using ROC curves demonstrated that the CBCT images had a larger area under the curve (0.940) than the panoramic radiographs (0.579). CONCLUSION: Three-dimensional evaluation of the sinus with CBCT was significantly more reliable in detecting pathology than panoramic imaging.
Cone-Beam Computed Tomography
;
Dental Implants*
;
Humans
;
Maxillary Sinus*
;
Pathology
;
Radiography, Panoramic
;
Retrospective Studies
;
ROC Curve
2.Light transmittance of CAD/CAM ceramics with different shades and thicknesses and microhardness of the underlying light-cured resin cement.
Zahra JAFARI ; Homayoon ALAGHEHMAND ; Yasaman SAMANI ; Mina MAHDIAN ; Soraya KHAFRI
Restorative Dentistry & Endodontics 2018;43(3):e27-
OBJECTIVES: The aim of this in vitro study was to evaluate the effects of the thickness and shade of 3 types of computer-aided design/computer-aided manufacturing (CAD/CAM) materials. MATERIALS AND METHODS: A total of 120 specimens of 2 shades (A1 and A3) and 2 thicknesses (1 and 2 mm) were fabricated using VITA Mark II (VM; VITA Zahnfabrik), IPS e.max CAD (IE; IvoclarVivadent), and VITA Suprinity (VS; VITA Zahnfabrik) (n = 10 per subgroup). The amount of light transmission through the ceramic specimens was measured by a radiometer (Optilux, Kerr). Light-cured resin cement samples (Choice 2, Bisco) were fabricated in a Teflon mold and activated through the various ceramics with different shades and thicknesses using an LED unit (Bluephase, IvoclarVivadent). In the control group, the resin cement sample was directly light-cured without any ceramic. Vickers microhardness indentations were made on the resin surfaces (KoopaPazhoohesh) after 24 hours of dark storage in a 37°C incubator. Data were analyzed using analysis of variance followed by the Tukey post hoc test (α = 0.05). RESULTS: Ceramic thickness and shade had significant effects on light transmission and the microhardness of all specimens (p < 0.05). The mean values of light transmittance and microhardness of the resin cement in the VM group were significantly higher than those observed in the IE and VS groups. The lowest microhardness was observed in the VS group, due to the lowest level of light transmission (p < 0.05). CONCLUSION: Greater thickness and darker shades of the 3 types of CAD/CAM ceramics significantly decreased the microhardness of the underlying resin cement.
Ceramics*
;
Curing Lights, Dental
;
Fungi
;
Hardness
;
In Vitro Techniques
;
Incubators
;
Polytetrafluoroethylene
;
Resin Cements*
3.Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography.
Hanadi SABBAN ; Mina MAHDIAN ; Ajay DHINGRA ; Alan G LURIE ; Aditya TADINADA
Imaging Science in Dentistry 2015;45(2):73-80
PURPOSE: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. MATERIALS AND METHODS: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head orientations. The scans were acquired using a Hitachi CB-MercuRay CBCT machine. The scanned volumes were reconstructed. Horizontal and vertical measurements were made and were compared to measurements made after simulating the head position to corrected head angulations. Data was analyzed using a two-way ANOVA test. RESULTS: Statistical analysis revealed a significant interaction between the mean errors in vertical measurements with a marked difference observed at the extension head position (P<0.05). Statistical analysis failed to yield any significant interaction between the mean errors in horizontal measurements at various head positions. CONCLUSION: Head orientation could significantly affect the vertical measurements in CBCT scans. The main head position influencing the measurements is extension.
Cone-Beam Computed Tomography*
;
Dental Implants
;
Dimensional Measurement Accuracy
;
Head*
;
Humans
;
Patient Positioning
;
Skull
4.The reliability of tablet computers in depicting maxillofacial radiographic landmarks.
Aditya TADINADA ; Mina MAHDIAN ; Sonam SHETH ; Taranpreet K CHANDHOKE ; Aadarsh GOPALAKRISHNA ; Anitha POTLURI ; Sumit YADAV
Imaging Science in Dentistry 2015;45(3):175-180
PURPOSE: This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). MATERIALS AND METHODS: A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. RESULTS: Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. CONCLUSION: Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs.
Archives
;
Connecticut
;
Dataset
;
Humans
;
Radiography, Dental, Digital
;
Radiography, Panoramic
;
Radiology Information Systems
5.An unusual presentation of osteoblastoma of the maxilla: A case report
Joonbum LIM ; Nicole HINCHY ; Nora ODINGO ; Dan COLOSI ; Mina MAHDIAN
Imaging Science in Dentistry 2021;51(4):455-460
This report presents a rare case of maxillary osteoblastoma in a 17-year-old female. The patient presented with dull pain and facial asymmetry inferior to the left zygoma. An intraoral examination found a painless swelling on the buccal gingival tissue in the left posterior maxilla. Panoramic radiographs and multidetector computed tomographic images revealed an ill-defined, non-corticated, mixed attenuating entity of osseous density located within the left posterior maxilla apical to the left maxillary molars. The entity exhibited a heterogeneous internal structure with a fine granular appearance, and the periphery showed a partial hypo-attenuating rim along the antero-medial aspect. Expansion of the left posterior maxilla accompanied with displacement of the left maxillary sinus floor was noted. External root resorption of the first and second molars was noted, as well as postero-superior displacement of the third molar. The histopathologic diagnosis of the biopsy was osteoblastoma. Complete excision of the tumor was performed.