1.Perforator stroke and stenting of intracranial arterial stenosis
Feng-Qi YU ; Bo HONG ; Jian-Min LIU ;
Journal of Interventional Radiology 2006;0(12):-
Perforator stroke(PS)is one of peri-procedural complications associated with stenting of intracranial arterial stenosis.A lot of perforator arteries are derived from intracranial arteries with difference from coronary arteries,because once the intracranial perforator arteries of crucial regions are occluded,may lead to fatal prognosis.Three hypothesis have been used to explain PS including snow-plowing,stent jailing effect and in-stent neointimal growth.In vivo models,investigators have already found these phenomenas.After much attention been paid on PS,authors have published a report covered with a large amount of cases in 2006. The author figured out that patients with perforator infarct adjacent to the stenotie segment(PIAS)under MRI beforehand would have higher chance occurring PS after stenting of intracranial stenosis.The patients with priority of PS easily are affected by the morphology,location,etiology,sites,the type and equipments.Many yet unsolved problems including the prevention would arouse us to go deeper into for the exploration of the mechanism.(J Intervent Radiol,2007,16:858-862)
2.Study on requirement forecasting of medical consumptive materials based on Kalman filter
Tiebing LIU ; Liming TANG ; Jingjie YU ; Min WU ; Shitao QI
Chinese Medical Equipment Journal 2003;0(12):-
An analysis method for requirement of medical consumptive materials on Kalman filter is put forward.An analysis mathematical model is established at first,its solution process is carried out at same time,and then an example using this solution is given according to the working practice.At last,the shortcomings using classical Kalman filter were discussed and a new method using adaptive Kalman filter was proposed.
3.Experiment study of rabbit joint articular cartilage defects repaired by thermosensitive CS/PVA composite hydrogel engineered hTGF-β1 transfected bone marrow mesenchymal stem cells
Baiwen QI ; Aixi YU ; Shaobo ZHU ; Min ZHOU
Chinese Journal of Microsurgery 2011;34(3):203-206,后插3
Objective To investigate the experiment effects of rabbit joint articular cartilage defects repaired by thermosensitive CS/PVA composite hydrogel engineered hTGF-β1 transfected bone marrow mesenchymal stem cells. Methods Bone marrow mesenchymal stem cells were isolated and cultured in vitro. The positive rate of transfection was defected by cell immunohistochemistry methods after Ad-hTGF-β1 transfected for 1 week. Twenty-four adult New Zealand white rabbits with full articular cartilage defects were randomly divided into 4 groups, each group had 6 animals, both hind limbs were used in the experiment. Group A: hydrogel combined with transfected cells; Group B: hydrogel combined with untransfected cells; Group C: hydrogel group; Group D: blank control group. Specimens and histological observation were used to evaluate the repair effect after 16 weeks according to Pineda's score. Results The positive rate of hTGF-β1 expression in BMSCs was about 85.4% after transfection. After 16 weeks the defects of group A were repaired by cartilage-like tissue, the cell arrangement and densities of regenerated cartilage were similar to normal cartilage, type Ⅱ collagen immunohistochemistry were positive. There was a significant difference in Pineda's score compaired with other groups (P < 0.05). Conclusion Rabbit articiular cartilage defects could be repaired by CS/PVA hydrogel engineered hTGF-β1-transfected bone marrow mesenchymal stem cells.
4.Renal papillary adenoma in transplant donor kidney: report of a case.
Xue-juan BAI ; Min YANG ; Qi YU ; Ning LI
Chinese Journal of Pathology 2009;38(5):353-354
Adenoma
;
metabolism
;
pathology
;
surgery
;
Humans
;
Keratin-7
;
metabolism
;
Kidney Neoplasms
;
metabolism
;
pathology
;
surgery
;
Kidney Transplantation
;
Living Donors
;
Male
;
Mucin-1
;
metabolism
;
Young Adult
5.Diagnosis of hereditary tyrosinemia type I: clinical study of ten patients.
Xiao-yu LI ; Min-lian DU ; Si-qi ZHUANG
Chinese Journal of Pediatrics 2006;44(6):470-471
Child, Preschool
;
Female
;
Humans
;
Infant
;
Male
;
Methionine
;
blood
;
Tyrosine
;
blood
;
Tyrosine Transaminase
;
deficiency
;
Tyrosinemias
;
blood
;
diagnosis
;
enzymology
;
pathology
;
therapy
6.Different active ingredients of medicinal plant based on function differentiation of homologous gene.
Yuan YUAN ; Jun YU ; Lu-qi HUANG ; Xu-min WANG
China Journal of Chinese Materia Medica 2015;40(6):1023-1026
In the research field of quality control in Chinese medicinal materials, variation in active ingredients of medicinal plant is always the key and hot issues. With the development of high-throughput sequencing technologies and reducing cost, a large numbers of genes from medicinal plant were cloning and provide a solid foundation for further research of gene structure and its biological function, and also provides conditions for explore active ingredient variation and its quality control from the perspective of molecular pharmacognosy. This paper introduces the concept of homologous gene, gene duplication and classification. We prospect the function of duplicated genes in the role of molecular mechanism research about variation in active ingredients, aiming at providing a new way for medicinal materials quality control.
Drugs, Chinese Herbal
;
analysis
;
Gene Duplication
;
Plant Proteins
;
genetics
;
Plants, Medicinal
;
chemistry
;
genetics
;
Quality Control
7.The application value of atropine before tracheal intubation under general anesthesia in elderly patients undergoing endobronchial ultrasound-guided transbronchial needle aspiration biopsy
Hui MA ; Min REN ; Guoxin ZHANG ; Shuyu YU ; Yongxiang ZHANG ; Yuechuan LI ; Qi WU
Chinese Journal of Geriatrics 2021;40(2):216-220
Objective:To investigate the value of atropine administration before tracheal intubation under general anesthesia in the elderly patients undergoing endobronchial ultrasound-guided transbronchial needle aspiration(EBUS-TBNA)biopsy.Methods:This was a case-control study.A total of 87 elderly hospitalized patients receiving chest enhanced CT test suggesting the risk of lung cancer with enlargement of mediastinal lymph nodes in 7 regions were scheduled to undergo endobronchial ultrasound-guided transbronchial needle aspiration(EBUS-TBNA)biopsy under general anesthesia.The patients were randomly divided into two groups by flipping a coin: the atropine group(n=40)and the control group(n=47). The indicators for evaluating the application values of atropine included preoperative, intra-operative and postoperative systolic blood pressure(SBP), diastolic blood pressure(DBP), heart rate, oropharyngeal and airway secretion volume, oxygen saturation, operation time, positive diagnosis rate and postoperative adverse reactions.Results:SBP and DBP were lower in the atropine group than in the control group before endotracheal intubation(131.7±15.3 mmHg vs.140.7±13.7 mmHg, 79.1±7.6 mmHg vs.85.6±7.4 mmHg, t=2.885 and 4.061, P<0.05). There was no significant difference in SBP and DBP 10 min after endoscopic operation and 10 min after tracheal extubation between the atropine group versus the control group(SBP: 109.1±11.2 mmHg vs.105.0±12.2 mmHg, 136.9±23.0 mmHg vs.129.9±11.2 mmHg, DBP: 66.9±7.5 mmHg vs.68.0±8.3 mmHg, 77.6±10.9 mmHg vs.78.5±6.4 mmHg, t=-1.617, 0.687, -1.751 and 0.448, P>0.05). There was no significant difference in HR between the two groups before endotracheal intubation( t=1.416, P>0.05), while HR was higher in the atropine group than in the control group 10 min after endoscopic operation and 10 min after tracheal extubation( t=-3.323 and -2.181, P<0.01 and P<0.05). The change rates of SBP and DBP were lower in the atropine group than in the control group 10 min after endoscopic operation and 10 min after tracheal extubation( t=7.947, -6.962, -3.187 and -3.232, P<0.01). The change rate of HR was lower in the atropine group 10 min after endoscopic operation and was higher 10 min after tracheal extubation than in the control group( t=-6.467 and -4.131, P<0.01). There were significant differences in the volume of oropharyngeal and airway secretions and fingertip oxygen saturation between the two groups before endotracheal intubation and 10 min after tracheal extubation( t=-2.334, 2.759, -3.314 and -2.767, P<0.01). The endoscopic operation time was less in the atropine group than in the control group with no statistically significant difference[(25.9±5.7)min vs.(26.4±4.7)min, t=0.391, P>0.05]. There was no significant difference in postoperative adverse reactions between the atropine group versus the control group(34 patients or 85.0% vs.43 patients or 91.5%, χ2=1.247, P>0.05). Conclusions:The application of atropine before tracheal intubation under general anesthesia is beneficial to stabilizing the intraoperative blood pressure and heart rate, and can reduce the production of postoperative oropharyngeal and airway secretions in elderly patients undergoing endobronchial ultrasound-guided transbronchial needle aspiration biopsy.
8.A new metallic oxide semiconductor field effect transistor detector for use of in vivo dosimetry
Zhen-Yu QI ; Xiao-Wu DENG ; Shao-Min HUANG ; De-Hua KANG ; Rosenfeld ANATOLY ;
Chinese Journal of Radiation Oncology 1992;0(04):-
To investigate the application of a recently developed metallic oxide semiconductor field effect transistor(MOSFET)detector for use in vivo desimetry.Methods The MOSFET detector was calibrated for X-ray beams of 8 MV and 15 MV,as well as electron beams with energy of 6,8,12 and 18 MeV.The dose linearity of the MOSFET detector was investigated for the doses ranging from 0 up to 50 Gy using 8 MV X-ray beams.Angular effect was evaluated as well in a cylindrical PMMA phantom by changing the beam entrance angle every 15?clockwise.The MOSFET detector was then used for a breast cancer patient in vivo dose measurement, after the treatment plan was verified in a water phantom using a NE-2571 ion chamber,in vivo measurements were performed in the first and last treatment,and once per week during the whole treatment.The measured doses were then compared with planning dose to evaluate the accuracy of each treatment.Results The MOSFET detector represented a good energy response for X-ray beams of 8 MV and 15 MV,and for electron beams with energy of 6 MeV up to 18 MeV.With the 6 V bias,Dose linearity error of the MOSFET detector was within 3.0% up to approximately 50 Gy,which can be significantly reduced to 1% when the detector was calibrated before and after each measdurement.The MOSFET response varied within 1.5% for angles firm 270?to 90?.However,maximum error of 10.0% was recorded comparing MOSFET response between forward and backward direction.In vivo mea surement for a breast cancer patient using 3DCRT showed that,the average dose.deviation between measurement and calculation was 2.8%,and the maximum error was less then 5.0%.Conclusions The new MOSFET detector,with its advantages of being in size,easy use,good energy response and dose linearity,can be used for in vivo dose measurement.
9.Relationship between body fat distribution and bone mineral density in the aged
Jingbo YU ; Qi YAO ; Yibo ZHENG ; Jianjiang ZHANG ; Min ZHAO ; Shiyu WANG ; Nanfen SHEN
Chinese Journal of Geriatrics 2009;28(10):837-839
Objective To explore the relationship between bone mineral density(BMD) and body tat disrribution in the aged in Ningbo area of China. Methods The BMD of lumbar vertebra and total body bones as well as body composition were measured by dual-energy X-ray absorptiometry (DXA) in 61 aged males, and also in 63 aged females as control group. Results In the aged males, a negative correlation was found between BMD and age, while BMI, muscle, trunk fat were positively correlated with BMD. As for the aged female, age, BMI, muscle and fat were all positively correlated with BMD. Conclusions The correlation between body fat and BMD is closer in females than in males in the aged. There is a positive correlation between trunk fat and lumbar spine BMD, and it indicates that central obesity may have a protective effect on lumbar spine BMD.