1.Follow-Up Assessment after Percutaneous Mitral Valvuloplasty (PMV) with Inoue Balloon.
Young Youp KOH ; Min Su HYON ; Jeong Kyung KIM
Korean Circulation Journal 1998;28(11):1841-1851
BACKGROUND: Percutaneous Mitral Valvuloplasty (PMV) is the first-line treatment modality in selected patients with symptomatic mitral stenosis and more recently available Inoue single-balloon catheter technique produces good results with low incidence of complications. The purpose of this study was to evaluate the immediate and over 6 months follow-up results after successful PMV with an Inoue balloon and to identify the predictive factors for the results. METHODS: From May 1995 to Feburary 1997, a PMV with an Inoue balloon was tech-nically successful in 114 (95%) of the 119 patients treated at the Sejong General Hostpital. In this study, a series of echocardiographic follow-up were performed in 54 patients with rheumatic mitral stenosis, at least 6 months after their successful PMV. In PMV, the inflation was conducted in steps, starting with a recommended maximum size of balloon by the Inoue criteria. After each inflation, the mitral valve opening and competence were evaluated by Transesophageal echocardiography (TEE) and continuing increase balloon size. RESULTS: Echocardiographic follow-up assessment was performed in 54 patients serially in a interval of 3 months or 6 months. Their mean age was 46+/-11 years (24 to 66 years) and the mean total echocardiographic score was 7.1+/-1.6. A optimal result was obtained in 95% of the cases (51/54). The post-PMV mitral valve area increased to 1.95+/-0.37 cm 2 and 1.79+/-0.28 cm 2 by 2-D and Doppler method, the average transmitral mean diastolic pressure gradient decreased to 5.16+/-2.8 mmHg and LA pressure was decreased to 11.28+/-8.2 mmHg. The newly developed and aggravated mitral regurgitation was observed in 17 patients (31.5%). The restenosis was noted in 2 cases (3.7%) after 1 year follow-up. The pre-procedural echocardiographic score for leaflet mobility, thickening and calcification was more higher in patients with restenosis. There was significant tendency of decrement in the mitral valve area in patients with a echocardiographic score=8 compared with those< or =8 over 6 months after the PMV. CONCLUSION: PMV with the Inoue balloon under TEE guide as a combined treatment modality of patient with symptomatic mitral stenosis is relatively safe and achieves good immediate and midterm follow-up results. The echocardiographic score is considered as useful predictor of midterm results and restenosis after PMV with Inoue balloon.
Blood Pressure
;
Catheters
;
Echocardiography
;
Echocardiography, Transesophageal
;
Follow-Up Studies*
;
Humans
;
Incidence
;
Inflation, Economic
;
Mental Competency
;
Mitral Valve
;
Mitral Valve Insufficiency
;
Mitral Valve Stenosis
2.Percutaneous Balloon Mitral Valvuloplasty Guided by Transesophageal Echocardiography.
Seong Hoon PARK ; Myung A KIM ; Min Su HYON
Korean Circulation Journal 1997;27(7):744-757
BACKGROUND: Balloon mitral valvuloplasty is a favorable procedure as a therapy for mitral stenosis because it minimizes morbidity and shorten hospital stay compared with surgical mitral commissurotomy or mitral valve replacement. Recent reports about concomitant transesophageal echocardiography guide in addition to fluoroscopy suggest that transesophageal echocardiograpy can provide additional benefits during balloon mitral valvuloplasty especially in transseptal puncture, balloon positioning, evaluation of immediate result, and early detection of complications. We performed this study to identify the potential benefits of on-line transesophageal echocardiography guide during balloon mitral valvuloplasty. METHOD: We performed balloon mitral valvuloplasty under on-line transesophageal echocardiography guide in addition to fluoroscopy in 70 patients(male:14, female:56, mean age:44+/-13) with rheumatic mitral stenosis from May 1995 to May 1996. Thirty-two(46%) patients had atrial fibrillation. Included patients were symptomatic with more than NYHA class 2 symptom. Patients with mitral valve score more than 11 and mitral regurgitation more than 2/4 were excluded. Inoue balloons were utilized in all cases. RESULTS: The average mitral valve area increased from 0.9+/-0.2cm2 before valvuloplasty to 1.8+/-0.4cm2 after valvuloplasty(p<0.0001). The averagetransmitral pressure gradient measured by continuous wave Doppler decreased from 14+/-6mmHg before valvuloplasty to 5+/-2mmHg after valvuloplasty(p<0.0001), and the average left atrial pressure measured by catheterization decreased form 22+/-8 mmHg before valvuloplasty to 11+/-5mmHg after valvuloplasty(p<0.0001). The average procedure time was 64+/-22 minutes(ranged from 13 to 150 minutes) and the average fluoroscopy time was 19+/-15 minutes(ranged from 1 to 94 minutes). Two patients underwent surgery due to severe mitral regurgitation associated with papillary muscle rupture which developed after valvuloplasty. In one patient, transesophageal echocardiography detected pericaridal tamponade during the procedure and the transducer was quickly switched to transthoracic transducer to guide the pericardial puncture site. The pericardial tamponade was drained with pigtail catheter and the patient underwent balloon mitral valvuloplasty successfully a week later. Four patients were pregnant at the time of the valvuloplasty procedure and the valvuloplasty was successfully performed with minimal fluoroscopy time(1-3 minutes) without complications in all four patients. Five patients had thrombus in left atrial appendage, but the transesophageal echocardiography was useful in monitoring the ballon position during the procedure and the valvuloplasty was successfully performed without embolic complications in all five patients. CONCLUSION: The transesophageal echocardiography is a very useful guiding adjunct during balloon mitral valvuloplasty in transseptal puncture, balloon positioning, evaluation of immediate result, early detection of complications, and shortening fluoroscopy time especially in pregnant women.
Atrial Appendage
;
Atrial Fibrillation
;
Atrial Pressure
;
Cardiac Tamponade
;
Catheterization
;
Catheters
;
Echocardiography, Transesophageal*
;
Female
;
Fluoroscopy
;
Humans
;
Length of Stay
;
Mitral Valve
;
Mitral Valve Insufficiency
;
Mitral Valve Stenosis
;
Papillary Muscles
;
Pregnant Women
;
Punctures
;
Rupture
;
Thrombosis
;
Transducers
3.Percutaneous Mitral Balloon Valvuloplasty in Patients with Left Atrial Appendage Thrombi.
Myung A KIM ; Min Su HYON ; Seong Hoon PARK
Korean Circulation Journal 1997;27(6):666-670
BACKGROUND: Percutaneous mitral balloon valvuloplasty(PMV) is a good treatment modality for patient with mitral stenosis(MS). But it is considered relatively contraindicated in patients with left artrial thrombi because of high risk of embolism. Limitted studies have suggested the feasibility of PMV in patients with left atrial appendage(LAA) thrombi. This study was performed to evaluate the feasibility and safty of PMV in patients with LAA thrombi using Inoue balloon under the transesophageal echocardiographic (TEE) monitoring. METHOD: PMV was performed in 5 patients diagnosed as MS with LAA thrombi from October, 1995 to July, 1996. Four cases were female, and one case was male. Their mean age was 525(46-58years old). Two of them had history of cerebrovascular accident(CVA). The duration of anticoagulant treatment was 6-49 moths. All patients underwent PMV using Inoue balloon catheter under the TEE monitoring. RESULTS: EKG finding of all 5 patients were atrial fibrillation(Af). Their mitral valve score were 5-10(Mean score was 82). Transmitral mean pressure gradient was decreased from 14.62.1 to 5.82.0mmHg, and mitral valve increased from 0.840.43 to 1.720.19 after PMV. There was no procedure related complication. In 3 cases of them LAA thrombi diappeared in the follow up TEE. In two patients, the LAA thrombi were calcified and remained unresolved at the time of follow up TEE( 6month-and 12 month-F/U, eath). CONCLUSION: Although the reported number of PMV in patients with LAA thrombi is small in this study, we believe that, with special precaution and TEE monitoring, LAA thrombi is no longer an absolute contraindication to PMV.
Atrial Appendage*
;
Balloon Valvuloplasty*
;
Catheters
;
Echocardiography
;
Electrocardiography
;
Embolism
;
Female
;
Follow-Up Studies
;
Humans
;
Male
;
Mitral Valve
;
Moths
4.Transesophageal Echocardiographic Evaluation of Pulmonary Venous Flow before, after and One-year after Percutaneous Mitral Valvulopasty in Patients with Mitral Stenosis in Sinus Rhythm.
Min Su HYON ; Myung A KIM ; Sung Hoon PARK
Korean Circulation Journal 2000;30(2):134-140
BACKGROUND: To evaluate the influence of changes in mitral valve area (MVA) and left atrial pressure on pulmonary vein flow (PVF) we analyzed PVF with transesophageal echocardiography (TEE) before, after and one-year after percutaneous mitral valvuloplasty (PMV) in patients with mitral stenosis (MS) in sinus rhythm. METHODS: PMV was guided with TEE. Follow-up TEE was done about one year after PMV. MVA and transmitral mean gradient (TMG) were measured. Systolic velocity (S), diastolic velocity (D), atrial reversal velocity (AR), their time-velocity integral (S-TVI, D-TVI, AR-TVI) and their ratio (S/D ratio, S-TVI/D-TVI ratio were evaluated. RESULTS: The number of patients was twenty-two (F:20). The age was 39+/-9 years (range:26-64). Follow-up duration was 16+/-6 months (range:7-28). MVA increased from 0.9+/-0.2 cm2 to 1.9+/-0.3 cm2 after PMV and decreased to 1.7+/-0.3 cm2 on follow-up TEE significantly. TMG decreased from 15.4+/-4.3 mmHg to 5.5+/-1.9 mmHg after PMV and was 6.2+/-2.4 mmHg on follow-up. S increased significantly on follow-up at both pulmonary vein (PV). D increased on follow-up at left PV. S/D ratio increased on follow-up at both PV. AR increased on follow-up at both PV. S-TVI increased after PMV at left PV and increased on follow-up at both PV. D-TVI had no change. S-TVI/D-TVI ratio increased on follow-up at left PV. AR-TVI increased on follow-up at right PV. CONCLUSIONS: The main changes after PMV in patients with MS in sinus rhythm were increasing tendency in S, S-TVI, S/D ratio, S-TVI/D-TVI ratio and AR. And these changes were statistically significant on follow-up TEE rather than immediately after PMV.
Atrial Pressure
;
Echocardiography*
;
Echocardiography, Transesophageal
;
Follow-Up Studies
;
Humans
;
Mitral Valve
;
Mitral Valve Stenosis*
;
Pulmonary Veins
5.Electrical Cardioversion of Chrome Nonvalvelar Atrial Fibrillation under Transesophageal Echocardiographic Guidance.
Min Su HYON ; Sang Hun LEE ; Sung Je CHO ; Seoung Hoon PARK ; Myung A KIM
Korean Circulation Journal 1997;27(5):488-500
BACKGROUND: We performed electrical cardioversion for the patients with chormic nonvalvular atrial fibrillation under the transesophageal echocardiographic guidance after anticoagulation to evaluate the safety of this procedure and the effects of electrical cardioversion on the atrial function. METHODS: After anticoagulation therapy with coumadine for three weeks, we tried chemical cardioversion with amiodarone first. Failed cases were included in this study. Pre-cardioversion transesophageal echocardiographic parameters were measured after exclusion of thrombi. After sedation with intravenous midazolam, direct-current cardioversion was done with the transesophageal echocardiographic probe in situ. Immediately after sinus conversion, we measured echocardiographic parameters again. Spontaneous echo contrast(SEC), left atrial appendage flow velocity, pulmonary vein flow velocity and time-velocity-integral(TVI), transmitral flow velocity, TVI and deceleration time were measured. All patients were anticoagulated for at least 4 weeks after cardiovesion. RESULTS: The total number of patients was forty one(24 males, 17 females) with the mean age of 58 years(range : 39-70). Mean duration of atrial fibrillation was 65 months(range : 1-360). Hypertension(12), dilated cardiomyopathy(10), cerebrovascular accidents(6), ischemic heart disease(2) and chronic lung disease(1) were associated. There were no complications. SEC increased or newly appeared in 18(43.9%) patients after sinus conversion. The left atrial appendage emptying velocity decreased(32.8+/-17.4 vs. 22.1+/-11.4cm/sec, p=0.020) and systolic TVI of both upper pulmonic vein increased significantly after sinus conversion. In two cases, early systolic forward flow(S1) of pulmonic vein appeared after sinus conversion. Transmitral E velocity decreased(86.9+/-28.8 vs. 76.3+/-30.6cm/sec, p=0.006) and the deceleration time increased(164+/-49 vs. 206+/-53msec, p=0.000) after sinus conversion. Transmitral A velocity was still low(34.9+/-19.5cm/sec) and E/A ratio was high(2.6+/-1.4) immediately after sinus conversion. CONCLUSION: After appropriate anticoagulation therapy and exclusion of left atrium and left atrial appindage thrombi with TEE we could perform electrical cardioversion safety without complications. The changes in transesophageal echocardiographic parameters after sinus conversion revealed the appearance of atrial mechanical activity in concordance with electrical activity. But these findings suggested atrial stunning or electromechanical dissociation which necessitates extended anticoagulation therapy until the full recovery of atrial mechanical function.
Amiodarone
;
Atrial Appendage
;
Atrial Fibrillation*
;
Atrial Function
;
Deceleration
;
Echocardiography*
;
Echocardiography, Transesophageal
;
Electric Countershock*
;
Heart
;
Heart Atria
;
Humans
;
Lung
;
Male
;
Midazolam
;
Pulmonary Veins
;
Veins
;
Warfarin
6.Treatment of Massive Pulmonary Embolism with Urokinase during Surgery for Femur Fracture.
Soon Im KIM ; Hyung Bin PARK ; Sang Yoon LEE ; Min Su HYON
Korean Journal of Anesthesiology 2000;39(3):447-452
A massive pulmonary embolism occurring during surgery is a fatal complication. Therefore, early detection and subsequent treatment of pulmonary emboli are important clinical challenges. In this report, an acute pulmonary embolism associated with cardiac arrest occurred during the surgical reduction of a femur fracture. It was diagnosed by echocardiography and treated with urokinase successfully. Therefore, we recommend the use of urokinase for the treatment of a intraoperative massive pulmonary embolism.
Echocardiography
;
Femur*
;
Heart Arrest
;
Pulmonary Embolism*
;
Urokinase-Type Plasminogen Activator*
7.Electrical Cardioversion of Atrial Fibrillation after Successful Percutaneous Balloon Mitral Valvuloplasty.
Sung Je CHO ; Sang Hoon LEE ; Woo Kyu KIM ; Min Su HYON ; Myung A KIM ; Seong Hoon PARK
Korean Circulation Journal 1998;28(8):1293-1298
Objectives: There was no previous report about the electrical cardioversion for the patients with atrial fibrillation after successful percutaneous ballon mitral valvuloplasty (PBMV). We performed electrical cardioversion after PBMV to evaluate the effectiveness of this procedure in the view of conversion to and maintenance of the sinus rhythm. METHODS: 28 patients who had persistent atrial fibrillation after successful PBMV were included in this study. All patients were anticoagulated with warfarin. Amiodarone was loaded and maintained before cardioversion. The PBMV procedures were guided by transesophageal echocardiography in all patients. Transthoracic echocardiography was done before and after PBMV and cardioversion, and was followed. RESULTS: The number of patients were 28 (male 9 and female 19) within the mean age of 50.3+/-12.0 years (24-66). Initially 24 patients (86%) succeeded in electrical cardioversion. The energy required for successful conversion was 230+/-75J, on average. There were no complications except for the transient sinus bradycardia in 2 cases. The mean follow-up duration was 357+/-144 days and when followed-up, the sinus rhythm was maintained in 15 patients out of 24 with initial success (63%). No factor was significantly related to the success of cardioversion, but left atrial dimension after 1 month of PBMV was significantly related to the maintenance of the sinus rhythm. CONCLUSIONS: This study suggests that electrical cardioversion of atrial fibrillation after successful PBMV is favorable and recommendable treatment modality of chronic valvular atrial fibrillation with high conversion rate (88%) and good maintenance rate (63%).
Amiodarone
;
Atrial Fibrillation*
;
Bradycardia
;
Echocardiography
;
Echocardiography, Transesophageal
;
Electric Countershock*
;
Female
;
Follow-Up Studies
;
Humans
;
Warfarin
8.Transesophageal Echocardiography during and Three Months after Electrical Cardioversion of Chronic Nonvalvular Atrial Fibrillation.
Min Su HYON ; Myung A KIM ; Seong Hoon PARK
Journal of the Korean Society of Echocardiography 1998;6(1):11-20
OBJECTIVES: To evaluate the serial changes in left atrial function we performed electrical cardioversion of chronic nonvalvular atrial fibrillation under the monitoring of transesophageal echocardiography(TEE) and followed the success cases with TEE. METHODS: All patients were anticoagulated from three weeks prior to and till four weeks after cardioversion. After exclusion of thrombi, direct-current cardioversion was done with the probe in situ. Immediately after comersion, TEE repeated. Follow-up TEE was done in cases whose rhythm were sinus over three months. Spontaneous echo rontrast(SEC): appendage emptying velocity, filling velocity, diameter, area, emptying fraction ', pulmonary vein systolic(S) velocity, diastolic(D) velocity, atrial reversal(AR) velocity, systolic time-velocity-integral(S - TVI), diastolic- TVI(D-TVI), S/D ratio, S-TVI/D-TVI ratio, AR duration : transmitral E velocity, A velocity, E- TVI, A- TVI, E/A ratio, A- TVI/E TVI ratio and deceleration time(DT) were measured. RESULTS: The number of patients was thirty-one(18 males) with the mean age of 58 years (range :39-69). Mean duration of AF was 56 months(range : 5-360). Mean follow-up duration was 8 months(range: 3-13). Hypertension(10), dilated cardiomyopathy(8), ischemic heart disease(2) and chronic lung disease(1) were associated. There were no complications, The SEC increased immediately after conversion and decreased at follow-up. The appendage emptpng velocity decreased after conversion and increased at follow-up significantly. The appendage emptpng fraction showed increasing tendency, but that was not statistically significant. The pulmonary vein S/D ratio and S - TVI/D - TVI ratio were increasing gradually after conversion and follow-up. The AR duration increased at follow-up. The transmitral E velocity was gradually decreasing after conversion and at follow-up. The E/A ratio decreased, the E-TVI decreased and the A-TVI/E-TVI ratio increased. The DT increased after conversion, but not changed significantly at follow-up. CONCLUSIONS: The immediate changes after conversion suggested "atrial stunning" or "electromechanical dissociation". The follow-up TEE suggested that left atrial function was recovering with maintenance of sinus rhythm.
Atrial Fibrillation*
;
Atrial Function, Left
;
Deceleration
;
Echocardiography, Transesophageal*
;
Electric Countershock*
;
Follow-Up Studies
;
Heart
;
Humans
;
Lung
;
Pulmonary Veins
9.Coronary Arteriovenous Fistula: Percutaneous Transcatheter Coil Embolization.
Myung A KIM ; Myung Young LEE ; Young Kwon KIM ; Min Su HYON ; Seok Keun HONG ; Seong Hoon PARK
Korean Circulation Journal 1997;27(12):1336-1340
BACKGROUND: Coronary arteriovenous(AV) fistula is a rare congenital disease, and seldom produce symptoms during childhood. However late complications can occur including congestive heart failure, myocardial ischemia, and bacterial endocarditis. Therefore surgical repair is recommended even if the patients are asymptomatic. In these days many investigators are interested in transcatheter embolization because of high procedural success rate without risks and morbidity associated with cardiac surgery. METHODS: Five patients(4 females and 1 male) of coronary AV fistula were treated with transcatheter coil embolization. All had symptom of chest pain. In coronary angiograms fistulous tracts were originated from left anterior descending artery(LAD) and drained to main pulmonary artery(MPA) in 4 cases. The other case had abnormal vessel from left circumflex artery(LCX) to bronchial artery. Transcatherter coil embolization were done with Judkins left guiding catheter, 018 inch Tracker or 3F Microferret catheter, and 018 inch coils. RESULTS: The fistula tracts were completely occluded in 3 cases after coil emboilzation. In 2 cases with multiple fistular vessels, major fistula were occluded, but minor vessels remained. There were no procedure related complications. CONCLUSION: Transcatheter coil embolization may be an effective treatment modality in coronary AV fistula with excellent result and minimal complications.
Arteriovenous Fistula*
;
Bronchial Arteries
;
Catheters
;
Chest Pain
;
Embolization, Therapeutic*
;
Endocarditis, Bacterial
;
Female
;
Fistula
;
Heart Failure
;
Humans
;
Myocardial Ischemia
;
Research Personnel
;
Thoracic Surgery
10.A Case of Multiple Systemic Embolism Associatied with Left Atrial Free-Floating Ball Thrombus.
Young Min KIM ; Seung Chul PARK ; Sun Young KWAK ; Wan Sup KIM ; Sung Koo KIM ; Min Su HYON ; Young Joo KWON ; Dong Won KIM
Korean Circulation Journal 1998;28(11):1889-1893
Left atrial thrombus is frequently associated with rheumatic mitral valvular heart disease. Left atrial thrombus is usually attached to the atrial wall, but rarely it is freely floating in the cavity. In that case the patient may present with the symptoms of acute hemodynamic decompensation due to the so-called "hole-in-one" effect or multiple systemic embolism. We report a case of multiple systemic embolism associated with left atrial free-floating ball thrombus in mitral valvular heart disease.
Echocardiography
;
Embolism*
;
Heart Valve Diseases
;
Hemodynamics
;
Humans
;
Thrombosis*