1.Reliability of automated versus handheld breast ultrasound examinations of suspicious breast masses
Gabin YUN ; Sun Mi KIM ; Bo La YUN ; Hye Shin AHN ; Mijung JANG
Ultrasonography 2019;38(3):264-271
PURPOSE: The purpose of this study was to assess the reliability of automated breast ultrasound (ABUS) examinations of suspicious breast masses in comparison to handheld breast ultrasound (HHUS) with regard to Breast Imaging Reporting and Data System (BI-RADS) category assessment, and to investigate the factors affecting discrepancies in categorization. METHODS: A total of 135 masses that were assessed as BI-RADS categories 4 and 5 on ABUS that underwent ultrasound (US)-guided core needle biopsy from May 2017 to December 2017 were included in this study. The BI-RADS categories were re-assessed using HHUS. Agreement of the BI-RADS categories was evaluated using kappa statistics, and the positive predictive value of each examination was calculated. Logistic regression analysis was performed to identify the mammography and US findings associated with discrepancies in the BI-RADS categorization. RESULTS: The overall agreement between ABUS and HHUS in all cases was good (79.3%, kappa=0.61, P<0.001). Logistic regression analysis revealed that accompanying suspicious microcalcifications on mammography (odds ratio [OR], 4.63; 95% confidence interval [CI], 1.83 to 11.71; P=0.001) and an irregular shape on US (OR, 5.59; 95% CI, 1.43 to 21.83; P=0.013) were associated with discrepancies in the BI-RADS categorization. CONCLUSION: The agreement between ABUS and HHUS examinations in the BI-RADS categorization of suspicious breast masses was good. The presence of suspicious microcalcifications on mammography and an irregular shape on US were factors associated with ABUS yielding a lower level of suspicion than HHUS in terms of the BI-RADS category assessment.
Biopsy, Large-Core Needle
;
Breast Neoplasms
;
Breast
;
Information Systems
;
Logistic Models
;
Mammography
;
Ultrasonography
2.Magnetic Resonance Imaging Factors Predicting Re-excision in Breast Cancer Patients Having Undergone Conserving Therapy.
Mijung JANG ; Sun Mi KIM ; Bo La YUN ; Sung Won KIM ; Eun Young KANG ; So Yeon PARK ; Jee Hyun KIM ; Yeongmi KIM ; Hye Shin AHN
Journal of the Korean Society of Magnetic Resonance in Medicine 2014;18(2):133-143
PURPOSE: The aim of this study was to determine the magnetic resonance imaging (MRI) features associated with re-excision due to the presence of a positive margin after breast conserving therapy (BCT) in breast cancer patients. MATERIALS AND METHODS: We reviewed the records of 286 consecutive breast cancer patients who received BCT between January 2006 and December 2007. Among 246 patients who had undergone BCT, 38 (15.4%) underwent immediate further surgery due to positive margin status. We analyzed the MRI findings using chi2 test, Fisher's exact test and t tests. Multivariate logistic regression was conducted for prediction of re-excision. RESULTS: Tumor size (p < 0.001), lesion multiplicity (p = 0.003), and non-mass-like enhancement (NMLE) type on MRI (p < 0.001) were associated with margin involvement in BCT. On preoperative MRI, larger size (> or = 5 cm) (odds ratio = 2.96), NMLE (odds ratio = 3.81), and multifocal lesions (odds ratio = 2.54) were positively associated with re-excision. In cases involving NMLE, segmental distribution was associated with a greater likelihood of immediate re-excision. CONCLUSION: Larger size, multiplicity, and NMLE on MRI are significantly associated with re-excision after BCT in breast cancer patients. For NMLE lesions, the segmental distribution pattern was predictive of re-excision.
Breast
;
Breast Neoplasms*
;
Humans
;
Logistic Models
;
Magnetic Resonance Imaging*
3.Reproducibility of Apparent Diffusion Coefficient Measurements in Malignant Breast Masses.
Mijung JANG ; Sun Mi KIM ; Bo La YUN ; Hye Shin AHN ; Soo Yeon KIM ; Eunyoung KANG ; Sung Won KIM
Journal of Korean Medical Science 2015;30(11):1689-1697
This study aimed to evaluate the reproducibility of apparent diffusion coefficient (ADC) measurements in malignant breast masses, and to determine the influence of mammographic parenchymal density on this reproducibility. Sixty-six patients with magnetic resonance findings of the mass were included. Two breast radiologists measured the ADC of the malignant breast mass and the same area on the contralateral normal breast in each patient twice. The effects of mammographic parenchymal density, histology, and lesion size on reproducibility were also assessed. There was no significant difference in the mean ADC between repeated measurements in malignant breast masses and normal breast tissue. The overall reproducibility of ADC measurements was good in both. The 95% limits of agreement for repeated ADCs were approximately 30.2%-33.4% of the mean. ADC measurements in malignant breast masses were highly reproducible irrespective of mass size, histologic subtype, or coexistence of microcalcifications; however, the measurements tended to be less reproducible in malignant breast masses with extremely dense parenchymal backgrounds. ADC measurements in malignant breast masses are highly reproducible; however, mammographic parenchymal density can potentially influence this reproducibility.
Adult
;
Aged
;
Aged, 80 and over
;
*Algorithms
;
Breast Neoplasms/*pathology
;
Diffusion Magnetic Resonance Imaging/*methods
;
Female
;
Humans
;
Image Enhancement/*methods
;
Image Interpretation, Computer-Assisted/*methods
;
Middle Aged
;
Reproducibility of Results
;
Sensitivity and Specificity
4.The Unusual Ultrasound Features of a Breast Cholesterol Granuloma Manifesting as an Intracystic Mass: Case Report and Literature Review.
Hye Shin AHN ; Sun Mi KIM ; Bo La YUN ; Mi Sun KIM ; Mijung JANG ; So Yeon PARK ; Sung Won KIM ; Eunyoung KANG ; Hye Young CHOI
Korean Journal of Radiology 2013;14(2):179-182
Cholesterol granuloma of the breast is a rare, benign disease. Here, we present the unique ultrasonographic findings of breast cholesterol granuloma manifesting as an intracystic mass. The findings of this case report may help expand existing knowledge regarding differential diagnosis of intracystic breast masses, which are found on ultrasonographic examination.
Biopsy, Needle
;
Breast Diseases/pathology/surgery/*ultrasonography
;
*Cholesterol
;
Diagnosis, Differential
;
Female
;
Granuloma, Foreign-Body/pathology/surgery/*ultrasonography
;
Humans
;
Mammography
;
Middle Aged
;
*Ultrasonography, Mammary
5.Increased whole grain, fruits and vegetable intake reduced oxidative stress in high school students.
So Hyeon KIM ; Sang Woon CHO ; Seong Su HWANG ; Mijung AHN ; Dukhee LEE ; Seung Wan KANG ; Yoo Kyoung PARK
The Korean Journal of Nutrition 2012;45(5):452-461
There is increasing evidence that dietary factors in plant-based diets are important for the prevention of chronic disease. Especially, phytonutrients in fruits and vegetables have been recognized as major contributors for the decreased level of oxidative stress. In this study, the effect of switching the dietary habit to high consumption of fruits and vegetables were evaluated on the parameters of serum antioxidant status in healthy high school students. Forty one students participated in a randomized controlled trial and were assigned to the control group (n = 18) or the intervention group (n = 23). The intervention group was provided for 8 weeks with the main food source being whole grain and vegetables. Anthropometric measurements, blood parameters and dietary intakes were measured, and compared before and after study. After 8 weeks, weight and BMI were significantly decreased in the intervention group (p = 0.000). The serum diacron reactive oxygen metabolites (d-ROMs) test resulted in a significantly decreased level only in the intervention group (p < 0.05) after 8 weeks, but serum biological antioxidant potential (BAP) was increased significantly in both groups (p < 0.001). Intake of energy, total fat, cholesterol and sodium in the intervention group were significantly decreased after 8 weeks (p < 0.05). Also, the intervention group had significantly increased vitamin and phytonutrient intakes of all-trans-beta-carotene, alpha-carotene, alpha-tocopherol, ascorbic acid, and total phenols (p < 0.05). Overall, the results of this study suggest that whole grain, fruits, and vegetables supplementation showed improvement of the adolescent health.
Adolescent
;
alpha-Tocopherol
;
Ascorbic Acid
;
Carotenoids
;
Cholesterol
;
Chronic Disease
;
Diet
;
Edible Grain
;
Food Habits
;
Fruit
;
Humans
;
Oxidative Stress
;
Oxygen
;
Phenol
;
Phenols
;
Sodium
;
Vegetables
;
Vitamins
6.The Radiopathologic Correlation of Breast Plasmacytoma.
Yun Jung BAE ; Mijung JANG ; Bo La YUN ; Hye Shin AHN ; Mi Sun KIM ; Sun Mi KIM ; So Yeon PARK ; Sung Won KIM ; Eunyoung KANG
Journal of the Korean Society of Medical Ultrasound 2013;32(3):207-211
Plasmacytoma of the breast is a rare tumorous condition referring to an extramedullary proliferation of malignant plasma cells, commonly associated with multiple myeloma. Due to its rarity, little is known about the radiologic findings to date. We report on a case of plasmacytoma of the breast as a manifestation of multiple myeloma with its radiopathologic correlation.
Breast*
;
Multiple Myeloma
;
Plasma Cells
;
Plasmacytoma*
7.Comparison of One- and Two-Region of Interest Strain Elastography Measurements in the Differential Diagnosis of Breast Masses
Hee Jeong PARK ; Sun Mi KIM ; Bo La YUN ; Mijung JANG ; Bohyoung KIM ; Soo Hyun LEE ; Hye Shin AHN
Korean Journal of Radiology 2020;21(4):431-441
OBJECTIVE: To compare the diagnostic performance and interobserver variability of strain ratio obtained from one or two regions of interest (ROI) on breast elastography.MATERIALS AND METHODS: From April to May 2016, 140 breast masses in 140 patients who underwent conventional ultrasonography (US) with strain elastography followed by US-guided biopsy were evaluated. Three experienced breast radiologists reviewed recorded US and elastography images, measured strain ratios, and categorized them according to the American College of Radiology breast imaging reporting and data system lexicon. Strain ratio was obtained using the 1-ROI method (one ROI drawn on the target mass), and the 2-ROI method (one ROI in the target mass and another in reference fat tissue). The diagnostic performance of the three radiologists among datasets and optimal cut-off values for strain ratios were evaluated. Interobserver variability of strain ratio for each ROI method was assessed using intraclass correlation coefficient values, Bland–Altman plots, and coefficients of variation.RESULTS: Compared to US alone, US combined with the strain ratio measured using either ROI method significantly improved specificity, positive predictive value, accuracy, and area under the receiver operating characteristic curve (AUC) (all p values < 0.05). Strain ratio obtained using the 1-ROI method showed higher interobserver agreement between the three radiologists without a significant difference in AUC for differentiating breast cancer when the optimal strain ratio cut-off value was used, compared with the 2-ROI method (AUC: 0.788 vs. 0.783, 0.693 vs. 0.715, and 0.691 vs. 0.686, respectively, all p values > 0.05).CONCLUSION: Strain ratios obtained using the 1-ROI method showed higher interobserver agreement without a significant difference in AUC, compared to those obtained using the 2-ROI method. Considering that the 1-ROI method can reduce performers' efforts, it could have an important role in improving the diagnostic performance of breast US by enabling consistent management of breast lesions.
8.False-negative results on computer-aided detection software in preoperative automated breast ultrasonography of breast cancer patients
Youngjune KIM ; Jiwon RIM ; Sun Mi KIM ; Bo La YUN ; So Yeon PARK ; Hye Shin AHN ; Bohyoung KIM ; Mijung JANG
Ultrasonography 2021;40(1):83-92
Purpose:
The purpose of this study was to measure the cancer detection rate of computer-aided detection (CAD) software in preoperative automated breast ultrasonography (ABUS) of breast cancer patients and to determine the characteristics associated with false-negative outcomes.
Methods:
A total of 129 index lesions (median size, 1.7 cm; interquartile range, 1.2 to 2.4 cm) from 129 consecutive patients (mean age±standard deviation, 53.4±11.8 years) who underwent preoperative ABUS from December 2017 to February 2018 were assessed. An index lesion was defined as a breast cancer confirmed by ultrasonography (US)-guided core needle biopsy. The detection rate of the index lesions, positive predictive value (PPV), and false-positive rate (FPR) of the CAD software were measured. Subgroup analysis was performed to identify clinical and US findings associated with false-negative outcomes.
Results:
The detection rate of the CAD software was 0.84 (109 of 129; 95% confidence interval, 0.77 to 0.90). The PPV and FPR were 0.41 (221 of 544; 95% CI, 0.36 to 0.45) and 0.45 (174 of 387; 95% CI, 0.40 to 0.50), respectively. False-negative outcomes were more frequent in asymptomatic patients (P<0.001) and were associated with the following US findings: smaller size (P=0.001), depth in the posterior third (P=0.002), angular or indistinct margin (P<0.001), and absence of architectural distortion (P<0.001).
Conclusion
The CAD software showed a promising detection rate of breast cancer. However, radiologists should judge whether CAD software-marked lesions are true- or false-positive lesions, considering its low PPV and high FPR. Moreover, it would be helpful for radiologists to consider the characteristics associated with false-negative outcomes when reading ABUS with CAD.
9.Ultrasonography and ultrasound-guided fine-needle aspiration biopsy can predict a heavy nodal metastatic burden in early-stage breast cancer
Hye Shin AHN ; Sun Mi KIM ; Mijung JANG ; Bo La YUN ; Eunyoung KANG ; Eun-Kyu KIM ; So Yeon PARK ; Bohyoung KIM
Ultrasonography 2021;40(4):520-529
Purpose:
This study aimed to predict a heavy nodal burden (≥3 metastatic axillary lymph nodes [LNs]) using axillary ultrasonography (US) and US-guided fine-needle aspiration biopsy (FNAB) in patients with early-stage breast cancer.
Methods:
We retrospectively reviewed the medical records of 403 women (404 cancers) who underwent US-guided FNAB for axillary LN staging from January 2006 to December 2015. US findings and US-guided FNAB results were reviewed and compared using pathology results as the reference. Diagnostic performance was analyzed, and clinicopathological and radiological findings were compared between patients with <3 metastatic LNs and ≥3 metastatic LNs.
Results:
The final pathology results revealed that 20.5% of cancers had heavy nodal metastases. US-guided FNAB showed significantly higher sensitivity (79.0% vs. 63.0%, P=0.009) and specificity (84.8% vs. 79.3%, P=0.036) in predicting heavy nodal metastases than did US. The presence of a larger number of suspicious LNs (two or more) on axillary US and positive FNAB results were significantly correlated with a heavy nodal burden in the multivariate analysis. The odds ratios were 4.20 (95% confidence interval [CI], 1.90 to 9.39) for two suspicious LNs, 9.40 (95% CI, 2.99 to 29.54) for three or more suspicious LNs, and 14.22 (95% CI, 6.78 to 29.82) for positive FNAB results.
Conclusion
The number of suspicious LNs detected on axillary US and FNAB results can help predict a heavy axillary nodal burden in patients with early-stage breast cancer.
10.A New Full-Field Digital Mammography System with and without the Use of an Advanced Post-Processing Algorithm: Comparison of Image Quality and Diagnostic Performance.
Hye Shin AHN ; Sun Mi KIM ; Mijung JANG ; Bo La YUN ; Bohyoung KIM ; Eun Sook KO ; Boo Kyung HAN ; Jung Min CHANG ; Ann YI ; Nariya CHO ; Woo Kyung MOON ; Hye Young CHOI
Korean Journal of Radiology 2014;15(3):305-312
OBJECTIVE: To compare new full-field digital mammography (FFDM) with and without use of an advanced post-processing algorithm to improve image quality, lesion detection, diagnostic performance, and priority rank. MATERIALS AND METHODS: During a 22-month period, we prospectively enrolled 100 cases of specimen FFDM mammography (Brestige(R)), which was performed alone or in combination with a post-processing algorithm developed by the manufacturer: group A (SMA), specimen mammography without application of "Mammogram enhancement ver. 2.0"; group B (SMB), specimen mammography with application of "Mammogram enhancement ver. 2.0". Two sets of specimen mammographies were randomly reviewed by five experienced radiologists. Image quality, lesion detection, diagnostic performance, and priority rank with regard to image preference were evaluated. RESULTS: Three aspects of image quality (overall quality, contrast, and noise) of the SMB were significantly superior to those of SMA (p < 0.05). SMB was significantly superior to SMA for visualizing calcifications (p < 0.05). Diagnostic performance, as evaluated by cancer score, was similar between SMA and SMB. SMB was preferred to SMA by four of the five reviewers. CONCLUSION: The post-processing algorithm may improve image quality with better image preference in FFDM than without use of the software.
Adult
;
Aged
;
*Algorithms
;
Breast Neoplasms/radiography
;
Calcinosis/radiography
;
Female
;
Humans
;
Mammography/*methods
;
Middle Aged
;
Prospective Studies
;
Radiographic Image Enhancement/*methods
;
Sensitivity and Specificity
;
Software