1.Detection of Mycobacterium tuberculosis in Sputum by using Polymerase Chain Reaction.
Korean Journal of Clinical Microbiology 1999;2(2):144-151
BACKGROUND: The recently developed nucleic acid amplification methods may provide us with very sensitive, specific and rapid tests for the detection of M. tuberculosis. So the aim of this study was to compare the commercial Amplicor M. tuberculosis kit and our in-house polymerase chain reaction (PCR) with the conventional culture and direct AFB staining method. Materials and METHODS: Among the total of 2,340 clinical specimens, 1,314 sputum samples were tested for the presence of M. tuberculosis by Amplicor PCR and 1,026 sputum samples were tested by in-house PCR performing with resin matrix preparation and DNA extraction, synthesized primer pair, detection using agarose gel electrophoresis. RESULTS: One hundred-seventeen specimens were positive by Amplicor PCR, 105 were positive by in-house PCR, 185 were positive by culture. The sensitivity of the Amplicor PCR for all of the specimens and for smear-positive and smear-negative specimens was 92.9%, 97.9% and 88.2%, respectively after discrepant analysis. The sensitivity of the in-house PCR for all of the specimens and for smear-positive and smear-negative specimens was 80.0%, 93.6% and 65.5%, respectively after discrepant analysis. The specificity of the Amplicor PCR and in-house PCR for all of the specimens was 97.9% and 99.0%, respectively. CONCLUSIONS: Amplicor PCR was more sensitive than in-house PCR, but there was another problems such as high false positive rate and high cost. So PCR may certainly become very useful in microbiological laboratories if PCR method is selected according to the laboratory conditions.
DNA
;
Electrophoresis, Agar Gel
;
Mycobacterium tuberculosis*
;
Mycobacterium*
;
Polymerase Chain Reaction*
;
Sensitivity and Specificity
;
Sputum*
;
Tuberculosis
2.Comparison of laboratory tests used for identification of the lupus anticoagulant.
Korean Journal of Clinical Pathology 1993;13(2):187-195
No abstract available.
Lupus Coagulation Inhibitor*
3.DNA analysis of body cavity fluids using flow cytometry.
Korean Journal of Clinical Pathology 1992;12(2):185-193
No abstract available.
DNA*
;
Flow Cytometry*
4.DNA analysis of body cavity fluids using flow cytometry.
Korean Journal of Clinical Pathology 1992;12(2):185-193
No abstract available.
DNA*
;
Flow Cytometry*
5.Determination of % PRA and identification of HLA antibody using home-made lymphocytes panel.
Korean Journal of Blood Transfusion 1992;3(1):71-77
No abstract available.
Lymphocytes*
6.A case of granular acute lymphoblastic leukemia.
Mi Yae YOUN ; Yun Jeong KIM ; Sam In CHOI
Korean Journal of Clinical Pathology 1992;12(3):311-315
No abstract available.
Precursor Cell Lymphoblastic Leukemia-Lymphoma*
7.A Case of Am.
Hyun Sook CHI ; Youn Mi CHOI ; Sog Woon KWON
Korean Journal of Blood Transfusion 1994;5(2):163-168
We report a case of weak subgroup A in a patient diagnosed as myelodysplastic syndrome. The patient's red cells was typed as O and his serum had anti-B. Red blood cell antibody screening test was negative. Am was confirmed by adsorption-elution test and saliva study.
Erythrocytes
;
Humans
;
Mass Screening
;
Myelodysplastic Syndromes
;
Saliva
8.Evaluation of Jnnotest HCV 3.0, Genedia HCV 3.0 Enzyme Immunoassay Reagents for Hepatitis C Virus Antibody Detection.
Youn Mi CHOI ; Yoo Sung HWANG ; Joe Eun WOO ; Do Hoon LEE
Korean Journal of Blood Transfusion 1996;7(1):11-22
The hepatitis C vims(HCV) is now known to be the chief cause of transfusion-associated non-A, non-B hepatitis. The ultimate goal of blood donor screening for anti-HCV antibodies is the specific exclusion of vital carriers from the blood donor population. Recently, a third generation anti-HCV screening(Green Cross Center Innotest HCV 3.0 Genedia HCV 3.0 ) and immunoblot assay, Inno-Lia HCV Ab III (Innogenetics) using antigens derived from the core and different nonstructural regions(NS3, NS4 and Ns5) of the HCV viral genome were developed. To evaluate the usefulness of these assays, anti-HCV reaction patterns of the Inno-Lia HCV Ab III or presence of HCV-RNA detected by reverse transcriptase-polymerase chain reaction(RT-PCR) were examined samples in which were repeatedly positive or discrepant with Abbott EIA-2, Innotest HCV 3.0 Genedia HCV 3.0 The reaction intensity of Innotest HCV 3.0 Genedia HCV 3.0 was higher than that of Abbott EIA-2. The sensitivity and specificity of Innotest HCV 3.0 and Genedia HCV 3.0 were 92.9% and 86.8%, respectively, and the positive and negative predictive values were 72.2% and 97.1%. both. The sensitivity and specificity of Abbott EIA-2 were 100% and 78.9%, respectively, and the positive and negative predictive values were 63.6% and 100%, respectively. We concluded that the new third generation HCV EIA reagents can decrease a false positivity of second generation EIA reagents and correlate well with detection of HCV-RNA by RT-PCR.
Blood Donors
;
Genome, Viral
;
Hepacivirus*
;
Hepatitis C Antibodies
;
Hepatitis C*
;
Hepatitis*
;
Humans
;
Immunoenzyme Techniques*
;
Indicators and Reagents*
;
Mass Screening
;
Sensitivity and Specificity
9.Analysis of Genetic Diversity of Salmonella typhi Isolates by Pulsed-Field Gel Electrophoresis.
Korean Journal of Clinical Pathology 1998;18(3):343-351
BACKGROUND: In many developing countries, typhoid fever remains an important cause of morbidity and mortality. In Korea, the disease is endemic with a high incidence. For an effective surveillance for this important human disease, the availability of detailed and accurate data on the molecular epidemiology of Salmonella typhi is crucial. In the present study, the pulsed-field gel electrophoresis (PFGE) technique, which has been used successfully to perform a comparative chromosomal DNA analysis, was used to assess the extend of molecular diversity among the strains of S. typhi isolated in Korea. METHODS: Included in the study were 51 strains of S. typhi isolated at Asan Medical Center (during the period from 1989 to 1996) and 16 isolates from other hospitals in Seoul, Chunbuk, Kyungpook, Pusan, Chonbuk and Chonnam. The isolates were analyzed by PFGE following XbaI digestion of DNA. PFGE patterns were assigned arbitrary types, compared by calculating a similarity coefficient and analyzed to generate dendrogram. RESULTS: PFGE analysis produced multiple patterns consisting of 15 to 19 fragments ranging in size 20 to 600 kb. These were arbitarily assigned 7 types, A, B, C, D, E, F, and G, and 5 and 10 subtypes within A and B, respectively. Of 54 isolates from Seoul, 9 showed the identical PFGE pattern, indicating that an outbreak of typhoid fever had occurred. Many of the identical patterns were also shared between isolates from Seoul and other areas. Similarity coefficient was between 0.606 and 1.0. CONCLUSIONS: Although a considerable genetic diversity exists among S. typhi isolates from different areas in Korea, suggesting a sporadic occurrence of typhoid fever, the identical PFGE patterns were also found among isolates from the same geographical areas of Seoul, indicating that some outbreaks had occurred. More efforts should be directed toward the epidemiological investigation of the cases to detect outbreaks and prevent further spread of the infection. The findings that many PFGE patterns are present among the Korea isolates of S. typhi suggest that PFGE may be used effectively with a considerable degree of discriminating power for the epidemiological investigation of typhoid fever.
Busan
;
Chungcheongnam-do
;
Developing Countries
;
Digestion
;
Disease Outbreaks
;
DNA
;
Electrophoresis, Gel, Pulsed-Field*
;
Genetic Variation*
;
Gyeongsangbuk-do
;
Humans
;
Incidence
;
Jeollabuk-do
;
Jeollanam-do
;
Korea
;
Molecular Epidemiology
;
Mortality
;
Salmonella typhi*
;
Salmonella*
;
Seoul
;
Typhoid Fever
10.Evaluation of MGIT 960 System for Recovery of Mycobacteria from Body Fluids.
Korean Journal of Clinical Microbiology 2003;6(1):69-73
BACKGROUND: In this study, we evaluated the BACTEC MGIT 960 system (Becton Dickinson Microbiology Systems, Sparks, Md, USA), which is fully automated, noninvasive and nonradiometric fluorescent indicator broth detection system, for the growth and detection of mycobacteria with body fluid specimens. METHODS: Total of 1,891 body fluid specimens were included (pleural fluid 752, ascitic fluid 629, cerebrospinal fluid 214, joint fluid 79, peritozol 54, others 163). Specimens were inoculated into MGIT and solid media (3% ogawa, Japan). Polymerase chain reaction was performed for the discrimination of Mycobacterium tuberculosis from Mycobacterium other than tuberculosis (MOTT). RESULTS: A total of 62 isolates of mycobacteria were recovered from all culture system. With MGIT system, 56 isolates were recovered, compared with solid system recovered 33 isolates. 29 isolates were recovered with MGIT only and 6 isolates recovered with solid media only. Among 62 isolates recovered, 11 isolates were positive in acid fast stain. 10 isolates were recovered with MGIT. One isolate was recovered with solid system. 51 isolates were negative in acid fast stain. Among this, 46 isolates were recovered with MGIT. The mean detection time was 14.2 days with MGIT system, and 38.2 days with solid media. Contamination rate for each system with body fluid specimens were 4.1% for MGIT and 1.7% for solid media. CONCLUSION: In body fluid, the MGIT system has the advantages of improved detection rate and rapid recovery than solid media to recover mycobacteria.
Ascitic Fluid
;
Body Fluids*
;
Cerebrospinal Fluid
;
Discrimination (Psychology)
;
Joints
;
Mycobacterium
;
Mycobacterium tuberculosis
;
Polymerase Chain Reaction
;
Tuberculosis