1.Skin adverse reactions to afatinib and their correlation with anti-lung cancer efficacy
Meihong DA ; Meiqi SHI ; Qiao YAN ; Haijing YANG ; Zhengbang DONG ; Fei WANG
Chinese Journal of Dermatology 2021;54(1):64-67
Objective:To investigate the type and severity of skin adverse reactions induced by afatinib in the treatment of lung cancer, and to analyze their correlation with anti-lung cancer efficacy.Methods:A case-case-control study was conducted on lung cancer patients treated with afatinib in ZhongDa Hospital, Southeast University from December 2016 to January 2018. The type and severity of skin adverse reactions were evaluated in 76 patients with lung cancer based on the National Cancer Institute-Common Terminology Criteria for Adverse Events (NCI-CTCAE) Version 4.0, and these patients were divided into 3 groups according to the severity of skin lesions, including grade-0, -1, and -2/3 groups. The patients underwent chest computed tomography (CT) examination every 3 months, and the tumor response to afatinib was evaluated according to the Response Evaluation Criteria in Solid Tumors (RECIST) . Anti-lung cancer efficacy of afatinib was compared among the patients with different grades of skin lesions by using the Kruskal-wallis H rank sum test. Results:After treatment with afatinib, 44 of the 76 patients with lung cancer achieved stable condition or partial remission, and 32 experienced disease progression. Skin adverse reactions occurred in 69 patients, and manifested as acneiform lesions in 42 (55.3%) patients, paronychia in 35 (46.1%) , mucosal erosions in 30 (39%) , hair changes in 8 (10.5%) , and hand-foot syndrome in 6 (7.9%) . Improvement was achieved in 3, 7 and 34 cases in the grade-0, -1, and -2/3 groups ( n = 7, 19 and 50 respectively) , respectively. There was a significant difference in the response rate among the 3 groups ( χ2 = 6.117, P = 0.047) , and the response rate was significantly higher in the grade-1 and -2/3 groups than in the grade-0 group (both P < 0.001) , and higher in the grade-2/3 group than in the grade-1 group ( P < 0.001) . Conclusion:The treatment of lung cancer with afatinib can cause various types of skin lesions, such as acneiform lesions, paronychia, mucosal erosions, hair changes and hand-foot syndrome, and the higher the severity of the skin lesions, the more marked the anti-lung cancer efficacy of afatinib.
2.Preliminary application of a novel distraction reductor in the surgical treatment of unstable distal radius fractures with metaphyseal volar comminution
Shengli XIA ; Meiqi QIAO ; Ziyuan MA ; Feng GAO ; Bin WANG ; Shaojun WANG ; Zeyi SUN ; Xiaoxiao ZHOU ; Cunguo YI ; Ribao SU ; Xiaoguang JIN ; Xiuhui WANG ; Xuhan CHEN
Chinese Journal of Orthopaedic Trauma 2023;25(8):663-669
Objective:To evaluate a novel distraction reductor in the surgical treatment of unstable distal radius fractures with metaphyseal volar comminution.Methods:From January 2019 to December 2020, 27 patients with unstable distal radius fracture complicated with metaphyseal volar comminution were treated at Department of Orthopaedics, Zhoupu Hospital Affiliated to Shanghai University of Medicine & Health Sciences. They were 6 males and 21 females, with an age of (69.4±9.4) years. All fractures were unilateral and closed, involving the right side in 17 cases and the left side in 10 cases. All patients were treated by internal fixation with an anatomical locking plate through the volar approach and the novel distraction reductor was used to reduce the fracture ends. Regular imaging examinations were performed to evaluate the reduction, maintenance and union of fractures after surgery. One year after operation, the curative efficacy was assessed by evaluation of the range of wrist motion, Disabilities of the Arm, Shoulder and Hand (DASH) score, Gartland-Werley score and Bartra radiology score.Results:All the operations went on successfully with a duration of (92.3±8.9) min. All the incisions healed primarily. The follow-up time was (15.9±2.9) months. The radial height, palmar tilt, ulnar inclination and articular surface step-off immediately after operation [(11.23±1.51) mm, 12.10°±3.44°, 20.54°±3.44°, and (0.95±0.42) mm] were not significantly lost compared with those one year after operation [(11.22±1.55) mm, 12.07°±3.44°, 20.51°±3.33°, and (0.93±0.40) mm] (all P>0.05). One year after operation, the range of wrist motion was good with dorsiflexion of 59.7°±5.5°, palm flexion of 63.0°±9.1°, pronation of 66.5°±5.5°, supination of 61.2°±5.6°, radial deviation of 22.7°±4.8°, and ulnar deviation of 30.3°±6.1°; DASH score was 13.5±5.5; Bartra radiology score was 88.6±6.5, giving an excellent and good rate of 88.9% (24/27);Gartland-Werley score was 2.7±2.1, giving an excellent and good rate of 92.6% (25/27). Follow-ups observed no poor fracture healing, internal fixation failure, tendon or nerve injury or traumatic arthritis. Conclusion:In the surgical treatment of unstable distal radius fractures with metaphyseal volar comminution, the novel distraction reductor can lead to ideal reduction of displaced fractures and effectively correct the shortening caused by volar cortex comminution to achieve satisfactory functional effects in clinic.