1.Changes of Matrix Metalloproteinase in Serum and Cerebrospinal Fluid of Children with Purulent Meningitis and Those Clinical Significances
xu-sheng, QI ; tong-guo, PAN ; yu-mei, YANG
Journal of Applied Clinical Pediatrics 1992;0(06):-
0.05,respectively).But most inte-restingly,the MMP-9 showed a positive relevance(r=0.686,P
2.Diagnostic Value of Combined Detection of IAA, ICA and GADA in the Classification of Diabetes Mellitus
Jianping YU ; Xiaojun DANG ; Pan GUO ; Junping MU ; Mei LA
Progress in Modern Biomedicine 2017;17(24):4759-4761
Objective:To study the diagnostic value of combined detection of IAA,ICA and GADA in the classification of diabetes mellitus.Methods:30 cases of patients with type 1 diabetes who were treated in our hospital from June 2015 to June 2016 were selected as A group,60 cases of patients with type 2 diabetes were selected as B group,50 cases of healthy people were selected as C group.The IAA,ICA and GADA of the three groups were detected by ELISA,and the positive rate of the three groups were compared.Results:The fasting glucose of A group was (10.12± 3.68) mmol/L,B group was (11.23± 3.26) mmol/L,A group and B group were significantly higher than that of C group (P<0.05),but there was no significant difference between A group and B group (P>0.05);the positive rates of GADA,ICA and IAA in A group and B group were significantly higher than those in C group (P<0.05),and the positive rates of GADA,ICA and IAA in A group were significantly higher than those in B group (P<0.05);the sensitivity and specificity of combined detection of IAA,ICA and GADA in type 2 and type 1 diabetes mellitus were significantly higher than that in the single test (P<0.05).Conclusions:The combined detection of IAA,ICA and GADA has a high diagnostic value in the classification of diabetes mellitus,which is worth clinical application.
3.Study on filtering blebs imaging by anterior segment optical coherence tomography
Weihua, PAN ; Mei, REN ; Xinping, YU ; Fan, LV
Chinese Ophthalmic Research 2009;27(12):1104-1108
Objective To seak a available way of evaluating morphology of filtering blebs after trabeculectomy is very important for forecasting the successful rate of surgery.At the present time,filtering blebs were commonly evaluated by using the slim lamp microscope,but it did not to exactly reflect the filtering passage.This study aimed to evaluate the morphology of filtering blebs after trabeculectomy with anterior segment optical coherence tomography (AS-OCT).MethodsThis was a prospective study.Sixty-nine eyes of 53 patients who had previously undergone trabeculectomy were selected in this study,including 25 eyes with open-angle glaucoma,38 eyes with close-angle glaucoma and 6 eyes with secondary glaucoma.These filtering blebs were classified into functional type (typeⅠandⅡ) and nonfunction type (type Ⅲ and Ⅳ) under the slit lamp microscope based on the van Buskirk grading scales.Intra-bleb morphology and structure were characterized as diffuse-like,cystic-like,encapsulating-like and flatten-like by AS-OCT in reference to the Leung method.The consistency between the two methods was evaluated by the Chi-Square test.Written informed consent was obtained from all the patients before surgery.ResultsThe average follow-up time was 10.78±11.0 months.All the patients finished the examination during the follow-up duration.The average intraocular pressure was(14.9±4.5)mmHg during the observation period.There were 38/69 (55.1%) functioning blebs and 31/69 (44.9%) non-function blebs under the slim lamp microscope.AS-OCT imaging showed diffuse-like blebs in 26 eyes (15.9%),cystic-like blebs in 11 eyes (27.5%),encapsulating-like blebs in 19 eyes (18.8%) and flatten-like in 13 eyes with the intraocular pressure of(13.16±3.77)mmHg,(15.36±2.92)mmHg,(15.77±5.07)mmHg and (16.62±5.33)mmHg,respectively,showing a significant difference among them (F=3.32,P<0.05).These patterns of different OCT presented a good consistency with the clinical outcome (χ~2=0.03,P=0.86).ConclusionAS-OCT allows the observation of filtering blebs after glaucoma surgery.It is probably to visualize the internal structure of filtering bleb and deep sclerectomy.Functional and dysfunctional filtering blebs delivery gives different OCT patterns.This could be a new way to assess the postoperative healing process.
4.Hyperbaric oxygen therapy can improve the learning capacity and memory in vascular dementia
Yu ZENG ; Fuqiong PAN ; Yajuan LI ; Mei PENG ; Lingling HUANG ; Fulan CHEN
Chinese Journal of Physical Medicine and Rehabilitation 2016;38(3):166-169
Objective To explore the influence of hyperbaric oxygen therapy (HBOT) on the learning and memory ability using a rat model of vascular dementia (VD).Methods Sixty Sprague-Dawley rats were selected and divided into a normal group,a sham operation group,a VD group and an HBOT group,each of 15 rats using a random number table.The improved four-vessel method was used to establish a VD model in all except the rats in the normal group,but for the sham operation group,the vertebral artery was not subjected to firing and the arteria carotis communis was not clipped.The HBOT group was then given HBOT for 7 days.The Morris water maze test was used to evaluate their learning and memory ability of all 4 groups.Results Compared to the normal group,the mean escape latency of the sham operation group,the VD group and the HBOT group was significantly longer in each case (P<0.05).Their platform quadrant crossing times were also significantly less,and their quadrant swimming distance as a proportion of their total swimming distance was significantly smaller (P<0.05).Compared with the sham operation group,the mean escape latency of the VD and HBOT groups was significantly longer (P<0.05),the times of crossing platform quadrant were less and their quadrant swimming distance was a smaller proportion of their total swimming distance.As compared with the VD group,the mean escape latency of the HBOT group was significantly shorter [(25.73±6.20) s],the average platform quadrant crossing times were significantly more [(9.51±2.25) times] and the platform quadrant swimming distance of the HBOT group was significantly longer [(494.72±208.26)],representing a significantly larger proportion of the total swimming distance [(28.71 ± 5.32) %] (P<0.05).Conclusion HBOT can effectively improve learning and memory in vascular dementia,at least in rats.
5.Evaluation of dynamic morphology of atrial septal defect by real-time three-dimensional transesophageal echocardiography
Huihong JIN ; Bowen ZHAO ; Chan YU ; Bei WANG ; Peng LI ; Mei PAN ; Lilong XU
Chinese Journal of Ultrasonography 2011;20(2):93-96
Objective To determine whether real-time three-dimensional transesophageal echocardiography(RT-3D TEE) is an accurate non-invasive technique for defining the morphology of atrial septal defects(ASD). Methods In 20 patients with secundum ASD, mean age 42.2 years (7 male, 13 female) ,live three dimensional surgical views of ASD were acquired,qualitative morphology of ASD such as the shape, presence of fenestrations and the defect margins were noted during the cardiac cycle. The measurements obtained from 2-dimensional transesophageal echocardiography(2D-TEE) and RT-3D TEE were compared to those obtained from stretched balloon diameter(SBD) or surgery. Measurements of the size and area change of ASD were validated during the cardiac cycle by RT-3D TEE,stepwise multiple linear regression analysis was performed to test the correlation between the maximum change ratios of area and diameter of ASD and age, atrial septal length, ASD shunting velocity, the maximum diameter of ASD and right ventricular systolic pressure. Results ① The morphology of ASD was circle-like or elliptical in systole,irregular or elliptical in diastole. ②The area and diameter of ASD measured by RT-3D TEE was minimal in isovolumetric contraction phase, maximal in isovolumetric diastole phase. The correlation coefficient of maximum diameter measured by 3D with SBD was 0.962 , greater than that by 2D and SBD (0.820). ③The change ratio of area and maximum diameter of ASD acquired by RT-3D-TEE was 11.48%-71.12% and 2.80%-43.87% respectively,and the correlation coefficient of them was 0.921. Conclusions RT-3D TEE using live 3D-Zoom mode accurately displayed the varying morphology,dimensions and spatial relations of ASD. RT-3D TEE can offer visualization morphological changing of ASD in different periods of cardiac cycle,providing more information for percutanous catheter intervention and open heart surgery.
6.Full-volume three-dimensional echocardiographic assessment of left ventricular volume in healthy human fetuses
Lili YU ; Bowen ZHAO ; Mei PAN ; Yuan YANG ; Peng LI ; Qian YANG
Chinese Journal of Ultrasonography 2010;19(7):604-608
Objective To evaluate the feasibility and accuracy of full volume three-dimensional echocardiography(FV3DE) for quantifying the left ventricular volume in healthy fetuses. Methods Two hundred and twenty-two normal fetuses with gestational ages between 20 and 40 weeks were investigated. Full volume three-dimensional, two-dimensional (2D) and M-mode images were acquired by Philips iE33 system and data was processed offline using QLAB analysis software. Left ventricular end-systolic volume(ESV) and end-diastolic volume ( EDV) were measured using semiautomated border detection echocardiographic techniques, and compared with 2D biplane Simpson's method and M-mode Teichholz formula. Results Thirty-six fetuses with poor three-dimensional images and 5 twin pregnancies were excluded,the study subjects consisted of 181 singleton fetuses. The highest concordance correlation ( r =0.987 for EDV, r =0.988 for ESV) P <0. 001) was noted between 2D biplane Simpson's and FV3DE-derived values with a small bias (0. 332 ml for EDV,0. 135 ml for ESV). The Bland-Altman analysis showed that FV3DE had the best reproducibility than M-mode Teichholz formula and 2D biplane Simpson's method. Intra- and interobserver error of EDV were 2.85% and 4.22% for FV3DE,8.37% and 8.98% for 2D biplane Simpson's rule,30. 63% and 54. 70% for M-mode Teichholz formula. Intra- and interobserver error of ESV were 2.34% and 6. 14% for FV3DE,6. 26% and 11.7% for 2D biplane Simpson's rule,43.06% and 66.03% for M-mode Teichholz formula. Conclusions FV3DE is a novel technique that can be more accurate than conventional methods in quantification of fetal left ventricular volumes, it may provide new insight into evolving fetal cardiac structure and function.
7.Papillary cystadenoma of epididymis in von Hippel-Lindau syndrome: report of a case.
Min-hong PAN ; Qin-he FAN ; Yan ZHU ; Mei-ning YU
Chinese Journal of Pathology 2012;41(2):125-126
Cerebellum
;
surgery
;
Cystadenoma, Papillary
;
complications
;
pathology
;
surgery
;
Epididymis
;
pathology
;
surgery
;
Follow-Up Studies
;
Genital Neoplasms, Male
;
complications
;
pathology
;
surgery
;
Humans
;
Keratin-7
;
metabolism
;
Kidney
;
surgery
;
Male
;
Middle Aged
;
Mucin-1
;
metabolism
;
Vimentin
;
metabolism
;
von Hippel-Lindau Disease
;
complications
;
metabolism
;
pathology
;
surgery
8.The current status and influential factors of uncertainty in illness in cardiac valvular surgery patients with cardiopulmonary bypass
Yajie LI ; Wenhong XIE ; Mei LI ; Yan YU ; Kangxing LIN ; Yongyi PAN ; Suhua ZHUANG
Chinese Journal of Behavioral Medicine and Brain Science 2014;23(2):148-151
Objective To investigate the current status of uncertainty in illness in cardiac valvular surgery patients with cardiopulmonary bypass and analyze its influential factor,and provide reference for effective intervention.Methods A total of 208 cardiac valvular surgery patients with cardiopulmonary bypass were recruited from 4 cardiovascular surgery in Guangdong and were investigated with the self-designed questionnaire,Mishel Uncertainty in Illness Scale (MUIS),Connor-Davidson Resilience Scale (CD-RISC),Medical Coping Modes Questionnaire (MCMQ),in the preoperative day and the day before discharge.The data were analyzed by single-factor and multiple-factor analysis.Results The average score of uncertainty in illness in cardiac valvular surgery patients with cardiopulmonary bypass was 99.09±11.41,and 92.3% of patients got a moderate uncertainty in illness level in the preoperative day.The average score of uncertainty in illness in the patients was 90.33± 10.32,and 91.8% of patients got a moderate uncertainty in illness level in the day before discharge.Multiple linear regression indicated that,age,cardiac valvular disease types,number of cardiac valvular surgery,optimism and yield were the protective factors of uncertainty in illness level.Average monthly household income,self-improvement,scores of resilience and confront coping were the risk factors of uncertainty in illness level.Conclusion The level of uncertainty in illness in cardiac valvular surgery patients with cardiopulmonary bypass is moderate.Age,average monthly household income,cardiac valvular disease types,number of cardiac valvular surgery,resilience and coping style are factors influencing uncertainty in illness level of patients.
9.Assessment of left ventricular twist of patients with hypertension by three-dimensional speckle tracking imaging
Xuanjia CHEN ; Jianhua WANG ; Minyu ZHANG ; Mei LIU ; Yu GAO ; Tao PAN
Chinese Journal of Ultrasonography 2014;23(4):289-292
Objective To observe features of twist of the left ventricle (LV) in patients of essential hypertension (EH) with LV normal geometry (LVN) by three-dimensional speckle tracking imaging (3D-STI).Methods Thirty EH patients with LVN and 32 healthy control subjects were included.From the dynamic images of LV apical two-and four-chamber-views and three-dimensional full volume dataset acquired,the following parameters were obtained:peak of LV basal,middle and apical segment rotation (Prot-B,Prot-M and Prot-A),peak of LV global segment twist (LV-tw) and rotation (LV-rot),the global radial and longitudinal displacement (Dr,Dl) and the global 3D displacement (D3d).The difference of these parameters was compared between EH and control groups,and the correlation between LV-tw and the displacements in EH group was studied.Results Compared with the normal control group,Prot-B,Prot-M,Prot-A,LV-tw,LV-rot,Dr,Dl and D3d of EH group were significantly increased (P < 0.01 or 0.05),and LV-tw showed significant correlation with Dr,Dl and D3d (P <0.01 or 0.05).Conclusions The evaluation of LV twist with 3DSTI in EH patients can reflect the changes of LV systolic function in early stage,3D-STI may provide a new modality for quantitative evaluation of early abnormality of LV function in clinical practice.
10.Study on Quality Control of Polygonum Capitatum from GAP Planting Base by HPLC Characteristic Spectrum
Yu XIE ; Lili ZHANG ; Liang XU ; Liyan ZHANG ; Jingwen TANG ; Mei PAN
Chinese Journal of Information on Traditional Chinese Medicine 2014;(8):70-72
Objective To establish HPLC characteristic spectrum of Polygonum Capitatum from GAP planting base, and provide reference for the overall quality control of Polygonum Capitatum. Methods HPLC analysis was performed on a DiamonsiL C18 chromatographic column (250 mm× 4.6 mm, 5μm) with the eluting system of gradient consisted of methanol and 0.2% H3PO4. The flow rate was 1.0 mL/min. The column temperature was maintained at 25℃ and the detection wavelength was at 254 nm.Results HPLC characteristic spectrum of Polygonum Capitatum samples from 10 different areas was established, which contained 11 common peaks, and the similarities of comparative results were over 90%.Conclusion The established method can be used to determine the characteristic spectrum of Polygonum Capitatum and can provide a basis for the overall quality control and quality standards of Polygonum Capitatum.