1.Research progress of intraoperative floppy iris syndrome during phacoemulsification
International Eye Science 2016;16(6):1063-1066
? Intraoperative floppy iris syndrome is a particular symptom in phacoemulsification, and it is often occurred in patients with the history of using alpha-1 adrenergic antagonist before cataract surgery. Although the pupil be fully mydriatic before the operation, the progressive constricting of the pupil, the relaxing of iris even the iridoptosis and the unstable anterior chamber still can be found during the phacoemulsification. If treated inappropriately, severe complications and terrible outcomes may happen, which would influenced the surgery effectives. This paper reviewed the epidemiological characteristics, pathogenesis, risk factors, clinical manifestations, complications, and coping strategies of the intraoperative floppy iris syndrome.
2.Thought imprinting analytic comprehensive therapy in a lowered resistance state
Yan MIN ; Xin ZHANG ; Yan MEI ; Weidong WANG
International Journal of Traditional Chinese Medicine 2011;33(3):217-219
Based on previous therapeutic experience, we introduce one specific technique of analytic comprehensive therapy in a lowered resistance state, belonging to the systematic psychotherapy of SPT. Analytic comprehensive therapy in a lowered resistance state is a specific and practical technique of SPT, which has been gradually standardized and matured with more than two decades of practice and improvement.
3.Systematic psychotherapy of TCM will-powered technique in the lower resistant state
Xueyu Lü ; Yan MEI ; Xin ZHANG ; Yan MIN ; Weidong WANG
International Journal of Traditional Chinese Medicine 2011;33(5):425-428
Will-powered technique training in the lower resistant state is an important therapy method of TCM psychology. The therapy refers to five aspects of improving cognitive and emotional function by using TIP technique, making imaginary training in the lowered resistant state, strengthening will-power training with situation and image technique, adopting information module imprinted technique and developing training technique. The content includes cultivating abilities in independence, resolution, firmness, and self-control. The technique has application value in clinic.
4.Study on medication rule of depressive disorder in medical records of Er Xu Ming Yi Lei An
Tao LI ; Yan MEI ; Xin ZHANG ; Weidong WANG
International Journal of Traditional Chinese Medicine 2011;33(7):617-618
Objective To study the origin, position, pathogenesis and differentiation rule of depressive disorder in ancient medical records, Er Xu Ming Yi Lei An. Methods Study medical records in ancient medical books, Ming Yi Lei An, Xu Ming Yi Lei An, Er Xu Ming Yi Lei An. Adopt Excel to establish medical records' database about depressive disorder, and use frequency analysis method to summarize medication rule of Chinese materia medica for treating depressive disorder. Results Six body symptoms referred in medical records are anorexia,lassitude, sweating, abdominal distension, insomnia, and hypochondriac pain, account 53.41% in top ten symptoms;regulating Qi method is the most frequently used treatment; The most frequently use prescriptions in a descending order are Xiaoyaosan, Buzhong Yiqi Tang, Taoren Chengqi Tang, Modified Guipi Tang, Wendan Tang, Liujun Zi Tang, Suanzaoren Tang, et. Most frequently applied medical herbs in a descending order are bupleurum, dried tangerine peel, white peony alba, tumeric root tuber, fossilia ossis mastoid, and Chinese angelica, et. Conclusion There are certain rules in the origin, pathogenesis, diagnosis and prescriptions of depressive disorder in ancient medical records, Er Xu Ming Yi Lei An.
5.The value of immunocytochemistry in differentiating benign and malignant serous effusion.
Ping MEI ; Xin-lan LUO ; Yan-hui LIU ; Heng-guo ZHUANG ; Wei ZHANG ; Guo-yan CHEN
Chinese Journal of Pathology 2005;34(6):368-369
Adenocarcinoma
;
diagnosis
;
pathology
;
Adult
;
Aged
;
Aged, 80 and over
;
Ascitic Fluid
;
chemistry
;
Cadherins
;
analysis
;
Calbindin 2
;
Carcinoembryonic Antigen
;
analysis
;
Diagnosis, Differential
;
Epithelial Cells
;
chemistry
;
Female
;
Humans
;
Immunohistochemistry
;
Keratin-5
;
analysis
;
Male
;
Middle Aged
;
Pericardial Effusion
;
chemistry
;
diagnosis
;
Pleural Effusion
;
chemistry
;
diagnosis
;
Pleural Effusion, Malignant
;
chemistry
;
diagnosis
;
S100 Calcium Binding Protein G
;
analysis
6.Energy metabolism in patients with chronic viral hepatitis and posthepatitic cirrhosis
Shu-Qing YU ; Qing-Hua MENG ; Yu-Xian LI ; Yan-Mei FENG ; Ming-Mei NI ; Jin-Huan WANG ; Xin WANG ;
Chinese Journal of General Practitioners 2005;0(10):-
Objective To evaluate the pattern of energy metabolism and nutrients intake in patients with chronic viral hepatitis and posthepatitic cirrhosis to effectively direct their nutrition therapy.Methods Resting energy expenditure (REE) was measured with open-circuit indirect Jorimetry in 60 patients with chronic viral hepatitis and 60 patients with posthepatitic cirrhosis.Their normal basal energy expenditure (BEE) was predicted by Harris-Benedict equation and energy intake (EI) was determined by diet recall. Correlation between REE and indicators for nutrition assessment was analyzed.Results REE was (77? 21) kJ?kg~(-1)?d~(-1) in 60 patients with pusthepatitic cirrhosis,significantly lower than BEE[(95?16) kJ? kg~(-1)?d~(-1)(P0.05,and their EI was (127?34) kJ?kg~(-1)?d~(-1),1.41?0.43 times as REE,in which PROI was (1.02?0.29) g?kg~(-1)?d~(-1),1.31?0.61 times as PROE (0.87?0.34) g?kg~(-1)?d~(-1),also indicating a negative nitrogen balance (-2.02?4.07).REE,EI and intake of three nutrients,serum level of albumin and prealbumin (PA) and body weight significantly decreased in patients with posthepatitic cirrhosis,as compared to those in patients with chronic viral hepatitis (P
7.Do transportation subsidies and living allowances improve tuberculosis control outcomes among internal migrants in urban Shanghai, China?
Lu Hui ; Yan Fei ; Wang Wei ; Wu Laiwa ; Ma Weiping ; Chen Jing ; Shen Xin ; Mei Jian
Western Pacific Surveillance and Response 2013;4(1):19-24
Introduction: Tuberculosis (TB) in internal migrants is one of three threats for TB control in China. To address this threat, a project was launched in eight of the 19 districts of Shanghai in 2007 to provide transportation subsidies and living allowances for all migrant TB cases. This study aims to determine if this project contributed to improved TB control outcomes among migrants in urban Shanghai.
Methods: This was a community intervention study. The data were derived from the TB Management Information System in three project districts and three non-project districts in Shanghai between 2006 and 2010. The impact of the project was estimated in a difference-in–difference (DID) analysis framework, and a multivariable binary logistic regression analysis.
Results: A total of 1872 pulmonary TB (PTB) cases in internal migrants were included in the study. The treatment success rate (TSR) for migrant smear-positive cases in project districts increased from 59.9% in 2006 to 87.6% in 2010 (P < 0.001). The crude DID improvement of TSR was 18.9%. There was an increased probability of TSR in the project group before and after the project intervention period (coefficient = 1.156, odds ratio = 3.178, 95% confidence interval: 1.305–7.736, P = 0.011).
Conclusion: The study showed the project could improve treatment success in migrant PTB cases. This was a short-term programme using special financial subsidies for all migrant PTB cases. It is recommended that project funds be continuously invested by governments with particular focus on the more vulnerable PTB cases among migrants.
8.Comparison of anterior chamber depth and central corneal thickness measuring values between Sirius and Pentacam
Yan, LI ; Shi-ming, CHENG ; Xin, YANG ; Jin-hai, HUANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(3):262-265
Background Biometry of the anterior ocular segment parameter is very important for the diagnosis and treatment of glaucoma and ocular injury as well as measurement of intraocular lens(IOL).Objective This study was to compare the differences in the anterior chamber depth(ACD) and the central corneal thickness (CCT) between Sirius and Pentacam and evaluate the agreement of these two measurement methods.Methods The ACD and the CCT of 38 right eyes from 38 health volunteers aged 23- 32 years were measured with both Pentacam and Sirius.Three times of measurement were pedormed on each eye for each method to obtain the average values.The repeatability and agreement from each method were assessed as intraclass correlation coefficient( ICC ) and coefficient of variation(CV) and the agreement between these two methods were evaluated using Bland-Altman mode.ResultsThe mean ACD value was( 3.18±0.21 ) mm from Pentacam with the ICC 0.995 and CV 0.066.The mean ACD value from Sirius was (3.22 ±0.21 )mm with the ICC 0.996 and CV 0.065.The difference value in ACD between two methods was 0.04 mm,showing a significant difference( t =-6.225,P<0.05 ) and a positive correlation (r=0.977) between two methods.The 95% limit of agreement was( -0.04-0.13)mm within 1 standard difference (SD) of the mean value( ±0.21mm),which was acceptable for clinical measurement.The CCT was( 535±33 )μm from Pentacam with the ICC 0.994 and CV 0.062.The CCT was(537±36)pm from Sirius with the ICC 0.999 and CV 0.067.The difference value in the CCT between two methods was about 2 μm,presenting a in significant difference ( t =1.771,P>0.05 ) and positive correlation ( r =0.985 ).The 95 % limit of agreement was ( - 11.64-15.65 ) μm within 1 SD of the mean value( ±34.27 pm),which was acceptable for clinical measurement.ConclusionsSirius and Pentacam show good agreement in the measurement of ACD and CCT.The two methods offer an alternative choice for the biological measurement of the anterior ocular segment.
9.Comparison of axial length and anterior chamber depth measurements by IOLMaster, Axis- Ⅱ A-scan and ODM 1000A sonograph
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(11):1023-1026
Background Axial length and anterior chamber depth are important parameters for the calculation of diopter of intraocular lens ( IOL ). Objective This study was to investigate and compare the measuring outcomes of axial length and anterior chamber depth with IOLMaster,Axis- Ⅱ A-scan and ODM 1000A sonograph.Methods This a observational study.Axial length and anterior chamber depth were measured in 83 eyes of 48 patients with IOLMaster,Axis-Ⅱ A-scan and ODM 1000A sonograph by the same operator.The measuring results were compared among the three methods.Results The axial length were(25.79±0.85) mm,(25.72± 0.82 )mm and ( 26.00 ±0.83 )mm respectively with Axis- Ⅱ,ODM 1000A sonograph and IOLMaster.The difference between Axis-Ⅱ and DM 1000A sonograph was (0.07 ± 0.35 )mm without statistical difference between them (t=1.711,P =0.091 ).The difference of axial length between IOLMaster and DM 1000A sonograph was ( 0.27 ±0.29) mm with a statistical difference between them ( t =-8.570,P =0.000 ).The difference between IOLMaster and Axis- Ⅱ was (0.21 ±0.32 ) mm and showed a statistical difference ( t =- 5.931,P < 0.01 ).The positive correlations were found in the axial length values by the each other comparison among the three instruments( r=0.916,0.938,0.928,P<0.01 ).The anterior chamber depth values were ( 3.81 ±0.21 ) mm,( 3.84 ±0.25 ) mm and ( 3.83 ±0.18 )mm respectively with Axis-Ⅱ,0DM 1000A sonograph and IOLMaster.The difference of anterior chamber depth between Axis- Ⅱ and DM 1000A was (0.03 ±0.17 ) mm without statistical difference between them ( t =- 1.324,P =0.189 ).The difference in the anterior chamber depth between IOLMaster and DM 1000A was (0.01 ±0.15 ) mm and that between IOLMaster and Axis-Ⅱ was( 0.01 ±0.12)mm without any statistical differences among them (t =0.815,P=0.417 ;t=-0.900,P=0.371 ).The high correlation between anterior chamber depth measurements were found by the each other comparison in the three instruments ( r =0.735,0.813,0.823,P < 0.01 ).Conclusions ODM 1000A sonograph can provide precise axial length and anterior chamber depth values.However,ODM 1000Asonograph can not substitute for IOLMaster in the measurement of the anterior chamber depth and axial length.
10.Comparison among different noncontact specular microscopes for the detection of corneal endothelial cell density
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Rong-rong, GAO ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(2):150-154
Background Clinical research showed that the corneal endothelial cell density value from different corneal specula microscopies exist diversity.The relevant literature of SP02,Tomey EM-3000 and SP3000P is still seldom up to now. Objective This research was to assess the repeatability of endothelial cell density measurements by SP02,Tomey EM-3000 and SP3000P respectively and the agreement among 3 kinds of endothelial microscopes.MethodsFifty-four healthy volunteers with the age 17-38 years old were included this research.The written informed consent was obtained from each subject before examination.The corneal endothelial cell densities in the right eyes were analyzed with SP02,Tomey EM-3000 and SP3000P respectively for 3 times under the automatic mode,and the analytical procedure of SP3000P measurement were divided into automatic mode SP3000P (A) and manual correction modes SP3000P( M).The repeatability of each specula microscopy was analyzed by calculating the intraclass correlation coefficients (ICC) and coefficient of variation ( CV ),and the 95% confidence intervals and plotting Bland-Altman graphs were used to analyze the agreement among these methods.ResultsThe mean corneal endothelial cell densities in the population <24 years were significantly higher than the ones ≥ 24 years (t =3.692,P<0.05 ),but no statistical difference was found between different gender ( t =0.335,P =0.739 ).The mean corneal endothelial cell densities were ( 3058 ± 260 ),( 2954 ± 229 ),( 2668 ± 258 ),( 2734 ± 268 ) cell/mm2 ; the ICCs were 0.957,0.940,0.972 and 0.972 and the CV were 0.063,0.061,0.056,0.058 for SP02,Tomey EM-3000,SP3000P (A) and SP3000P ( M ) respectively.The 95% confidence intervals were ( - 100.8 - 306.8 ),( 162.6 - 617.4 ),( 109.9-494.1 ) and ( -0.6 - 132.6 ) cell/mm2 for between SP02 and Tomey EM-3000,SP3000P ( A ) and SP02,SP3000P(A) and Tomey EM-3000,SP3000P(A) and SP 3000P(M) respectively.ConclusionsSP02,Tomey EM-3000 and SP3000P(A) have good repeatability in the measurement of corneal endothelial cell density,however the outcome is different.Therefore,it is not interchangeable for the detection of corneal endothelial cell density.The differences of corneal endothelial cell density obtained from these instruments shall be paid high attention for their differences.SP3000P(A) and SP3000P(M) can be used interehangeably and SP3000P(A) is a preferable choice due to its convenience and quickness.