1.Changes of Plasma Somatostatin in Children with Septic Shock
Ai-rong, HUANG ; Yi-mei, JIN ; Hao-mei, YANG
Journal of Applied Clinical Pediatrics 2006;0(22):-
Objective To explore the changes of plasma somatostatin(SST) in children with septic shock.Methods The level of plasma SST in children with septic shock (test group,n=21) on an empty stomach at shock stage,blood pressure and heart rate recovery stage,recovery stage(at that time clinical symptoms and signs disappeared,infection indicators such as blood routine and CRP returned to normal,about 6-12 days after admission) were detected by competive radioimmunassay,the level of SST in healthy children(healthy control group,n=25) on an empty stomach on morning was detected,too.The levels of plasma SST between septic shock concbined with paralytic ileus group and without paralytic ileus group were compared.Results 1.Level of plasma SST of test group at shock stage[(44.60?16.83) ng/L]was significantly lower than that of control group[(123.15?6.57) ng/L](t=-12.16 P0.05).The level of plasma SST of children with paralytic ileus [(28.10?7.0) ng/L] was significantly lower than that of children without paralytic ileus [(56.98?9.44) ng/L](t=-7.70 P
2.Application of the glycated haemoglobin in screening undiagnosed diabetes in hospitalised patients
Hailin PENG ; Mei JIN ; Jin QIAN ; Xia HUANG
The Journal of Practical Medicine 2017;33(14):2386-2388
Objective To assess the economic efficiency of glycated haemoglobin(HbA1C)determination in screening the undiagnosed diabetes among hospitalised patients. Methods Exclusive criteria were made based on the information of the electronic patient history,including age<18 years,hospitalization for diabetes treatment, and having received a transfusion within half a year. Pathology samples from participants were collected for blood routine analysis and HbA1C screening test. Screening the undiagnosed diabetes was based on the level of HbA1C. Results In this study ,1012 patients were enrolled ,78 patients with diabetes ,and 934 patients haven′t been diagnosed before. Among the 934 patients ,HbA1C level of 51 patients was over 6.5%(48 mmol/mol). These 51 patients (5.46%) were determined to have previously unknown diabetes. The prevalence of undiagnosed diabetes was 5.46% during the study period. The cost of HbA1C test was ¥1098 per new diagnosis of diabetes. Conclusions HbA1C is a simple ,inexpensive screening test for diabetes ,which can significantly improve the diagnostic efficiency,and the early detection of diabetes can slow the progression of complication and reduce the medical care expenditures.
3.Epithelial-stromal tumor of seminal vesicle: report of a case.
Ai-hua HUANG ; Ya-bo GAO ; Mei JIN
Chinese Journal of Pathology 2010;39(1):55-56
Diagnosis, Differential
;
Genital Neoplasms, Male
;
metabolism
;
pathology
;
surgery
;
Humans
;
Male
;
Middle Aged
;
Neoplasms, Glandular and Epithelial
;
metabolism
;
pathology
;
surgery
;
Neprilysin
;
metabolism
;
Receptors, Estrogen
;
metabolism
;
Receptors, Progesterone
;
metabolism
;
Seminal Vesicles
;
Stromal Cells
;
pathology
;
Vimentin
;
metabolism
5.Simultaneous determination of four anthraquinones in rat plasma by HPLC-FLD method and its pharmacokinetic study.
Jin-Qiu HUANG ; Xue-Mei YAN ; Fang FENG
China Journal of Chinese Materia Medica 2014;39(19):3850-3854
This paper aims to develop a method for the determination of aloe-emodin, rhein, chrysophanol and physcion and study the pharmacokinetic properties of four anthraquinones in rat plasma after oral administration of gardenia and rhubarb decoction. The plasma concentrations at different time points of four anthraquinones were determined by HPLC-FLD method. Plasma samples were extracted with liquid-liquid extraction procedure. Plasma samples were separated on a C18 column (4.6 mm x 150 mm, 5 μm), using 0.2% acetic acid and methanol as mobile phase at a flow rate of 1.0 mL min(-1) with gradient elution. The excitation and emission wavelengths were set at 430, 525 nm, respectively. DAS 2.0 software was applied to calculate the pharmacokinetic parameters. The results showed four anthraquinones can be absorbed. The main parameters of aloe-emodin, rhein, chrysophanol and physcion were as follows: C(max) for aloe-emodin was (0.085 ± 0.058), (3.772 ± 1.152), (0.464 ± 0.267), (0.028 ± 0.008) mg x L(-1) respectively; t(max) for rhein was (1.042 ± 0.510), (0.805 ± 0.307), (1.167 ± 0.283), (0.616 ± 0.162) h respectively; t½ for chrysophanol was (3.557 ± 1.250), (6.879 ± 1.126), (5.196 ± 2.032), (4.337 ± 1.816) h; AUC(0-t) for physcion was (0.504 ± 0.130), (9.558 ± 1.106), (2.545 ± 1.554), (0.052 ± 0.018) mg x h x L(-1). This paper developed a selective, accurate and sensitive HPLC-FLD method for the simultaneous determination of four anthraquiones in rat plasma.
Animals
;
Anthraquinones
;
blood
;
pharmacokinetics
;
Chromatography, High Pressure Liquid
;
instrumentation
;
methods
;
Drugs, Chinese Herbal
;
analysis
;
pharmacokinetics
;
Male
;
Rats
;
Rats, Sprague-Dawley
6.Reverse hybridization applied in detection on human papillomavirus infection of twenty-three subfamilies
Jin-Cai HE ; Xiao-Mei ZHOU ; Tao HUANG ; Wei REN ;
Chinese Journal of Laboratory Medicine 2001;0(01):-
Objective To establish a method of reverse hybridization to detect five subfamilies of low risk Human Papillomaviruses(HPV6,11,42,43 and 44)and eighteen subfamilies of high risk HPV (HPV16,18,31,33,35,39,45,51,52,53,56,58,59,66,68,73,83 and MM4)in one reaction.Methods Special probes for twenty-three HPV subfamilies were fixed on nylon membrane bars,biotin labeled general primers mediated polymerase chain reaction(GP-PCR)were applied in HPV DNA amplification.PCR amplified DNA fragments were reversely hybridized with special probes that were fixed on the membranes. All samples(136)detected by reverse hybridization method were paralleled with the methods of Hybridization Capture Ⅱ(HC-Ⅱ)and sequencing.Results Positive rate of the 136 samples detected by reverse hybridization was 41.9%,while HC-Ⅱ 42.6% and sequencing 40.4%.Reverse hybridization detection indicated coherence with the other two methods(Kappa 0.8644 and 0.9089,respectively).While sequencing was lab standard for DNA test,the sensitivity was 96.36%,specificity was 95.06%,accuracy was 95.59%.Conclusions Method of reverse hybridization is adaptable to 23 kinds of HPV subfamilies, which can confirm the exactly subfamilies of HPV infection.This method is adaptable in clinical detection of HPV,with high sensitivity,high specificity,simply and convenient operation and the results are easily to be read.
7.The effects of rhPDGF-BB combined with rhTGF-β1 on FAK mRNA expression of osteoclasts in the alveo-lar bone on the pressure side of orthodontic teeth in rats
Jiangtao ZHANG ; Mei MEI ; Jianguo LIU ; Ce JIANG ; Lei FENG ; Jin HUANG
Journal of Practical Stomatology 2014;(5):619-623
Objective:To study the effects of recombinant human platelet-derived growth factor-BB(rhPDGF-BB)combined with recombinant human transforming growth factor-β1 (rhTGF-β1 )on the expression of FAK mRNA of osteoclasts in the alveolar bone on the pressure side of orthodontic teeth in rats.Methods:Orthodontic tooth movement model was established in 160 male SD rats.The rats in experimental group were treated by injection of 10 ng rhPDGF-BB and 5 ng rhTGF-β1 in the buccal submucosal area of the mo-lar every other day from day 1 afterburner,while those in control group received equivalent volumes of PBS.The rats were sacrificed at 1,4,7,10 and 14 days(n=16)after appliance placement.Specimens were collected.Osteoclasts in the alveolar bone on the pres-sure side of the orthodontic teeth were observed by TRAP staining,the FAK mRNA expression was quantified by quantitative RT-PCR.Results:rhPDGF-BB combined with rhTGF-β1 significantly promoted an increasing number of osteoclasts on the compressing side(P<0.05),increased the expression of FAK mRNA at day 4 and 7(P<0.05),then decresed it to the control level(P>0.05) at day 14.Conclusion:Combination of rhPDGF-BB and rhTGF-β1 can increase the number of osteoclasts in the alveolar bone on compressing side,and promote FAK mRNA expression in osteoclasts.
8.Biocompatibility of rat’ s nature decellularized pancreatic biological scaffolds
Yingkuan SHAO ; Xialin YAN ; Zhiheng RAO ; Gaojian HUANG ; Jiawei LI ; Junjie HUANG ; Jin MEI ; Kezhi LIN
Acta Anatomica Sinica 2014;(4):561-568
Objective To harvest pancreatic tissues from rats , prepare decellularized bio-derived pancreatic scaffolds ( DBPS) , and to examine the integrity and biocompatibility of the scaffolds .Methods Normal pancreases were harvested from healthy adult SD rats .DBPS was prepared by perfusing SDS and Triton X-100 through bile duct and the portal vein, respectively.After decellularization, normal pancreatic tissue and DBPS were compared via HE staining , and transmission electron microscopy ( TEM ) . Abdominal wall and subcutaneous implantations were used to compare biocompatibility , and the remain quantity of residual protein and growth factors were determined via enzyme linked immunosorbent assay(ELISA).MTT assay was used to test the scaffolds’ cytotoxicity.The scaffolds were co-cultured with endotheliocyte .Results HE staining and TEM study indicated no residual cells in the DBPS as well as preservation of the complete extracellular matrix .The remain quantity of residual protein and growth factors in ECM was high .The abdominal wall and subcutaneous implantation revealed that DBPS triggered a lower immune response as compared to the control group.MTT assay showed little cytotoxicity .Endotheliocyte assembled and growed with the scaffolds together .Conclusion DBPS are completely decellularized , and exhibit a higher level of biocompatibility in vivo.Using the way of vessels can make the integrity of extracellular matrix to be fully preserves and contain more growth factors .So using vessels way is better than bile duct .
9.Comparison of anterior chamber depth and central corneal thickness measuring values between Sirius and Pentacam
Yan, LI ; Shi-ming, CHENG ; Xin, YANG ; Jin-hai, HUANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(3):262-265
Background Biometry of the anterior ocular segment parameter is very important for the diagnosis and treatment of glaucoma and ocular injury as well as measurement of intraocular lens(IOL).Objective This study was to compare the differences in the anterior chamber depth(ACD) and the central corneal thickness (CCT) between Sirius and Pentacam and evaluate the agreement of these two measurement methods.Methods The ACD and the CCT of 38 right eyes from 38 health volunteers aged 23- 32 years were measured with both Pentacam and Sirius.Three times of measurement were pedormed on each eye for each method to obtain the average values.The repeatability and agreement from each method were assessed as intraclass correlation coefficient( ICC ) and coefficient of variation(CV) and the agreement between these two methods were evaluated using Bland-Altman mode.ResultsThe mean ACD value was( 3.18±0.21 ) mm from Pentacam with the ICC 0.995 and CV 0.066.The mean ACD value from Sirius was (3.22 ±0.21 )mm with the ICC 0.996 and CV 0.065.The difference value in ACD between two methods was 0.04 mm,showing a significant difference( t =-6.225,P<0.05 ) and a positive correlation (r=0.977) between two methods.The 95% limit of agreement was( -0.04-0.13)mm within 1 standard difference (SD) of the mean value( ±0.21mm),which was acceptable for clinical measurement.The CCT was( 535±33 )μm from Pentacam with the ICC 0.994 and CV 0.062.The CCT was(537±36)pm from Sirius with the ICC 0.999 and CV 0.067.The difference value in the CCT between two methods was about 2 μm,presenting a in significant difference ( t =1.771,P>0.05 ) and positive correlation ( r =0.985 ).The 95 % limit of agreement was ( - 11.64-15.65 ) μm within 1 SD of the mean value( ±34.27 pm),which was acceptable for clinical measurement.ConclusionsSirius and Pentacam show good agreement in the measurement of ACD and CCT.The two methods offer an alternative choice for the biological measurement of the anterior ocular segment.
10.Comparison of axial length and anterior chamber depth measurements by IOLMaster, Axis- Ⅱ A-scan and ODM 1000A sonograph
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(11):1023-1026
Background Axial length and anterior chamber depth are important parameters for the calculation of diopter of intraocular lens ( IOL ). Objective This study was to investigate and compare the measuring outcomes of axial length and anterior chamber depth with IOLMaster,Axis- Ⅱ A-scan and ODM 1000A sonograph.Methods This a observational study.Axial length and anterior chamber depth were measured in 83 eyes of 48 patients with IOLMaster,Axis-Ⅱ A-scan and ODM 1000A sonograph by the same operator.The measuring results were compared among the three methods.Results The axial length were(25.79±0.85) mm,(25.72± 0.82 )mm and ( 26.00 ±0.83 )mm respectively with Axis- Ⅱ,ODM 1000A sonograph and IOLMaster.The difference between Axis-Ⅱ and DM 1000A sonograph was (0.07 ± 0.35 )mm without statistical difference between them (t=1.711,P =0.091 ).The difference of axial length between IOLMaster and DM 1000A sonograph was ( 0.27 ±0.29) mm with a statistical difference between them ( t =-8.570,P =0.000 ).The difference between IOLMaster and Axis- Ⅱ was (0.21 ±0.32 ) mm and showed a statistical difference ( t =- 5.931,P < 0.01 ).The positive correlations were found in the axial length values by the each other comparison among the three instruments( r=0.916,0.938,0.928,P<0.01 ).The anterior chamber depth values were ( 3.81 ±0.21 ) mm,( 3.84 ±0.25 ) mm and ( 3.83 ±0.18 )mm respectively with Axis-Ⅱ,0DM 1000A sonograph and IOLMaster.The difference of anterior chamber depth between Axis- Ⅱ and DM 1000A was (0.03 ±0.17 ) mm without statistical difference between them ( t =- 1.324,P =0.189 ).The difference in the anterior chamber depth between IOLMaster and DM 1000A was (0.01 ±0.15 ) mm and that between IOLMaster and Axis-Ⅱ was( 0.01 ±0.12)mm without any statistical differences among them (t =0.815,P=0.417 ;t=-0.900,P=0.371 ).The high correlation between anterior chamber depth measurements were found by the each other comparison in the three instruments ( r =0.735,0.813,0.823,P < 0.01 ).Conclusions ODM 1000A sonograph can provide precise axial length and anterior chamber depth values.However,ODM 1000Asonograph can not substitute for IOLMaster in the measurement of the anterior chamber depth and axial length.