1.The effects of different surface treatments on the shear bond strengths of two dual-cure resincements to CAD/CAM restorative materials
Nurullah TURKER ; Ulviye Şebnem BUYUKKAPLAN ; Ebru Kaya BAŞAR ; Mehmet Mustafa ÖZARSLAN
The Journal of Advanced Prosthodontics 2020;12(4):189-196
. The aim of the present study was to investigate the effects of surface treatments on the bond strengths between polymer-containing restorative materials and two dual-cure resin cements. MATERIALS AND METHODS.In the present study, rectangular samples prepared from Lava Ultimate (LU) and Vita Enamic (VE) blocks were used. The specimen surfaces were treated using CoJet sandblasting, 50 μm Al2O3 sandblasting, % 9 HF (hydrofluoric) acid, ER,Cr:YSGG laser treatment, and Z-Prime. Dual-cure resin cements (TheraCem and 3M RelyX U 200) were applied on each specimen’s treated surface. A micro-tensile device was used to evaluate shear bond strength. Statistical analysis was performed using the SAS 9.4v3. RESULTS. While the bond strengthusing TheraCem with LU or VE was not statistically significant (P=.164), the bond strength using U200 with VE was statistically significant (P=.006). In the TheraCem applied VE groups, Z-Prime and HF acid were statistically different from CoJet, Laser, and Sandblast groups. In comparison of TheraCem used LU group, there was a statistically significant difference between HF acid and other surface treatments. CONCLUSION. The bondingperformance between the restorative materials and cements were material type-dependent and surface treatment had a large effect on the bond strength. Within the limitations of the study, the use of both U200 and TheraCem may be suggested if Z-prime was applied to intaglio surfaces of VE. The cementation of LU using TheraCem is suitable after HF acid conditioning of the restoration surfaces.
2.Effects of staining liquids and finishing methods on translucency of a hybrid ceramic material having two different translucency levels.
Sebnem Ulviye BUYUKKAPLAN ; Mehmet Mustafa ÖZARSLAN ; Cağatay BARUTCIGIL ; Merve ARSLAN ; Kubilay BARUTCIGIL ; Elif Ece YOLDAN
The Journal of Advanced Prosthodontics 2017;9(5):387-393
PURPOSE: Beverages may affect the translucency of esthetic dental restorative materials. The aim of the present study was to investigate the effects of coffee and red wine on the translucency of a PICN material with two translucency levels, and finished with different methods. MATERIALS AND METHODS: 2M2 high translucent and translucent VITA Enamic hybrid ceramic blocks were investigated. Rectangular specimens with the dimensions of 12 mm × 14 mm × 2 mm were prepared. The specimens were finished and polished with different methods as suggested by the manufacturer. The translucency parameters of the specimens were evaluated before and after 24 hours, 7 days, and 28 days immersion in distilled water, coffee and red wine. Translucency parameters were measured using a portable spectrophotometer. RESULTS: At the end of 28 days, there was no statistically significant difference between the groups of specimens kept in coffee (P>.05). In the red wine groups, there was a statistically significant difference between the control group and all other groups (P<.05) at the end of 28 days. CONCLUSION: The translucency of hybrid ceramic for a restoration may not be important regarding the effects of coffee on translucency change because the specimens with different translucencies and finishing methods that were immersed to coffee had similar translucency parameters at the end of 28 days. The translucency of hybrid ceramic may be important in the case of red wine, however, since the results showed that highly translucent specimens exposed to red wine demonstrated better translucency parameters than specimens made from translucent blocks at the end of 28 days.
Beverages
;
Ceramics*
;
Coffee
;
Immersion
;
Methods*
;
Water
;
Wine
3.Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material.
Mehmet Mustafa ÖZARSLAN ; Ulviye Sebnem BUYUKKAPLAN ; Cagatay BARUTCIGIL ; Merve ARSLAN ; Nurullah TURKER ; Kubilay BARUTCIGIL
The Journal of Advanced Prosthodontics 2016;8(1):16-20
PURPOSE: Polymer infiltrated ceramic network (PICN) materials, also called hybrid ceramics, are new materials in dental market. The manufacturer of the PICN material VITA Enamic suggests 3 different finishing procedures for this new material. In the present study, surface roughness and color differences caused from different finishing procedures of VITA Enamic were investigated. MATERIALS AND METHODS: 120 specimens were prepared in dimensions 2 x 10 x 12 mm from VITA Enamic hybrid ceramic blocks with 'high translucency' and 'translucency 2M2' shades. The specimens were divided into 8 groups. For each group, different finishing procedures suggested by the manufacturer were performed. Surface roughness values were determined by a tactile portable profilometer. Color changes were evaluated using a clinical spectrophotometer. The data were analyzed using one-way ANOVA and Tukey's post-hoc comparison. The significance level was set at alpha=0.05. RESULTS: The roughest surfaces were observed in Glaze Groups. Their surface roughness values were similar to that of the control group. Clinical Kit and Technical Kit groups did not show a statistically significant difference regarding surface roughness (P>.05). The largest color difference regarding DeltaE00 was observed in Clinical Kit finishing groups. There were also statistically significant color changes between the groups (P<.05). However, all the groups showed clinically acceptable color change (DeltaE(00)<2.25) except Clinical Kit Groups (DeltaE(00)>2.25). CONCLUSION: Within the limitations of the present study, it may be suggested that finishing the VITA Enamic restorations by Technical Kit instead of Glaze and Clinical Kit gives better clinical performance in regard to surface roughness and shade matching.
Ceramics*
;
Polymers*
4.Comparing the precision of panoramic radiography and cone-beam computed tomography in avoiding anatomical structures critical to dental implant surgery: A retrospective study
Oznur ÖZALP ; Hüseyin Alican TEZERIŞENER ; Burak KOCABALKAN ; Ulviye Sebnem BÜYÜKKAPLAN ; Mehmet Mustafa ÖZARSLAN ; Göksel ŞIMŞEK KAYA ; Mehmet Ali ALTAY ; Alper SINDEL
Imaging Science in Dentistry 2018;48(4):269-275
PURPOSE: The aim of this study was to evaluate the correlations between measurements made using panoramic radiography and cone-beam computed tomography (CBCT) based on certain anatomical landmarks of the jaws, with the goal of preventing complications due to inaccurate measurements in the pre-surgical planning phase of dental implant placement. MATERIALS AND METHODS: A total of 56 individuals who underwent panoramic radiography and a CBCT evaluation before dental implant surgery were enrolled in the study. Measurements were performed to identify the shortest vertical distance between the alveolar crest and neighboring anatomical structures, including the maxillary sinus, nasal floor, mandibular canal, and foramen mentale. The differences between the measurements on panoramic radiography and CBCT images were statistically analyzed. RESULTS: Statistically significant differences were observed between the measurements on panoramic radiography and CBCT for all anatomical structures (P < .05). The correlation coefficients (r) between the paired samples obtained from panoramic radiography and CBCT were closely correlated (P < .05), with r values varying from 0.921 and 0.979 for different anatomical regions. CONCLUSION: The results of this study support the idea that panoramic radiography might provide sufficient information on bone height for preoperative implant planning in routine cases or when CBCT is unavailable. However, an additional CBCT evaluation might be helpful in cases where a safety margin cannot be respected due to insufficient bone height.
Cone-Beam Computed Tomography
;
Dental Implants
;
Jaw
;
Maxillary Sinus
;
Radiography, Panoramic
;
Retrospective Studies