1.Effects of Tangtong Formula on RSC96 Schwann Cells Apoptosis and Proliferation Induced by High Glucose
Xiaoxing LIU ; Xiaoyun ZHU ; Maoying WEI ; Lan DENG ; Mingdi LI
Chinese Journal of Information on Traditional Chinese Medicine 2017;24(10):49-52
Objective To screen the optimal dose of Tangtong Formula in vitro. Methods RSC96 Schwann Cells were cultivate by DMEM mediums which contains different concentrations of glucose (5–125 mmol/L). The prevention effects of Tangtong Formula at different concentrations (0.25, 0.5, 0.75, 1.0, 1.5, 2.0, 3.0, 5.0 mg/mL) on the proliferation of RSC96 Schwann Cells induced by high glucose were detected. After the RSC96 Schwann Cells were cultivated in 100 mmol/L and 125 mmol/L high glucose mediums for 72 h, the apoptosis of RSC96 Schwann Cells was detected by flow cytometry Annexin V/PI, and the apoptosis rate was calculate; the proliferation situation of RSC96 Schwann cells in different times was detected by CCK-8 method. Results RSC96 Schwann cells were in apoptosis after being intervened by 100 mmol/L and 125 mmol/L high glucose mediums. The apoptosis rates were respectively(7.46±0.96)% and(16.53±1.01)%, with statistical significance compared with control group (P<0.01). Different concentrations of Tangtong Formula could alleviate the inhibitory effect of high glucose on the proliferation of RSC96 Schwann cells, and the threshold concentration of Tangtong Formula in 24 h was 0.25 mg/mL. The concentrations of Tangtong Formula in 0.5 mg/mL, 1.0 mg/mL, and 1.5 mg/mL could inhibit the apoptosis of RSC96 Schwann cells induced by high glucos, compared with 125 mmol/L high glucose group, the apoptosis rate of RSC96 Schwann cells decreased significantly (P<0.05, P<0.01). Conclusion Among three different doses, when the dose of Tangtong Formula is in 1.5 mg/mL, the effects on inhibiting apoptosis are the best.
2.Comparison between HyperArc and conventional VMAT approach for brain metastases
Bo YANG ; Lang YU ; Zhiqun WANG ; Bei WANG ; Wenbo LI ; Jie ZHANG ; Xingliu WANG ; Hao ZHU ; Xiaoshen WANG ; Maoying LAN ; Feng ZHU ; Zhen ZHANG ; Ke HU ; Fuquan ZHANG ; Jie QIU
Chinese Journal of Radiation Oncology 2021;30(9):876-881
Objective:To compare the dosimetric parameters and plan complexity between newly-delicated HyperArc (HA) and conventional volumetric-modulated arc therapy (VMAT) in the treatment of brain metastases.Methods:For 26 patients with brain metastases, HA, conventional coplanar (Cop) and non-coplanar (Non-cop) VMAT plans with a prescription dose of 9 Gy 3fx or 6 Gy 5fx were generated. The dosimetric parameters for planning target volume (PTV), RTOG conformity index (RTOG CI), Paddick CI, homogeneity index (HI), gradient index (GI), maximum dose (D max) of brainstem and dose-volume parameters of brain-PTV(V 2Gy-V 26Gy) were statisticaly compared among these three approaches. In addition, the monitor unit (MU) and the plan complexity parameters (including MCSv and AlPO) were statistically compared. Results:To prevent missed targets during treatment, all plans were established with RTOG CI of greater than 1.1. For Paddick CI, HA provided significantly higher conformity (0.89±0.019) than Non-cop (0.87±0.036, P=0.001) and Cop (0.88±0.017, P=0.003) VMAT. For GI, the fastest dose fall-off was noted in HA (3.35±0.64), followed by conventional Non-cop VMAT of (3.70±0.80), and conventional Cop VMAT of (4.90±1.85)(all P<0.05). For the brainstem sparing, HA plan performed better than Non-cop plan[(604.14±531.61) cGy vs.(682.75±558.22) cGy, P<0.05)]. For normal brain tissue sparing, HA approach showed significant reduction than conventional Cop and Non-cop VMAT (both P<0.05). For MU, HA approach (2 872.60 ± 566.93) was significantly lower than those of Non-cop VMAT (3 771.28 ± 1 022.38, P<0.05) and Cop VMAT (4 494.08 ± 1 323.09, P<0.05). In terms of plan complexity, the MCSv of Cop plan was the lowest, indicating that the complexity was the highest ( P<0.05). The AlPO of HA was significantly higher than that of Non-cop VMAT ( P<0.05), suggesting that the complexity of HA plan was lower ( P<0.05). Conclusion:For the treatment of brain metastases, HA provides better conformity, more rapid dose fall-off, better sparing of brainstem and normal brain tissues and less plan complexity compared with conventional VMAT.
3.Implementation and assessment of software based on ESAPI compilation structure
Zhiqun WANG ; Bo YANG ; Jie ZHANG ; Lang YU ; Bei WANG ; Wenbo LI ; Gao ZHU ; Xiaoshen WANG ; Maoying LAN ; Xingliu WANG ; Zongkai ZHOU ; Weihua ZHU ; Zhen ZHANG ; Ke HU ; Fuquan ZHANG ; Jie QIU
Chinese Journal of Radiation Oncology 2021;30(11):1173-1177
Objective:To help clinicians simplify the post-processing operations of structures by developing rapid processing software for target area and organs at risk structures based on ESAPI.Methods:SmartStructure script software was developed based on ESAPI, verified and evaluated in clinical work. 10 cases of rectal cancer receiving neoadjuvant radiotherapy, 10 breast cancer treated with postoperative radiotherapy, 10 cervical cancer receiving postoperative radiotherapy, 10 nasopharyngeal carcinoma receiving radical radiotherapy and 10 lung stereotactic body radiotherapy (SBRT) were selected, and different types of tumors had different post-processing operations of structures. In each case, three methods were used for post-processing of structures. In the control group (manual group), normal manual processing was employed. In the experimental group 1(SmaStru-N group), scripts without templates were utilized. In the experimental group 2(SmaStru-P group). scripts combined with templates were adopted. The processing time of the three methods was compared. Clinicians scored the scripting software from multiple aspects and compared the feeling scores of scripting software and manual operation.Results:All three methods can be normally applied in clinical settings. The error rate in the manual group was 7.0%, 3.0% in the SmaStru-N group 0% in the SmaStru-P group, respectively. Compared with the manual method, SmaStru-N shortened the processing time of target area and organs at risk by 60.9% and 93.3% for SmaStru-P. In addition, SmartStructure was superior to manual method in terms of using feeling scores. Clinicians gave lower score for the" applicability" and" simplicity" , and higher score on the" accuracy" and" efficiency" .Conclusions:Compared with conventional manual structure processing method, SmartStructure software can rapidly and accurately process all structures of the target area and organs at risk, and its advantages become more obvious with the increasing number of structures that need to be processed. SmartStructure software can meet clinical requirements, reduce the error rate, elevate processing speed, improve the working efficiency of clinicians, providing basis for the development of adaptive radiotherapy.
4.A new automatic planning approach: clinical practice of Eclipse scripting application programming interface combined with RapidPlan
Zhaoyang LOU ; Chen CHENG ; Hongchang LEI ; Weihua ZHU ; Xiaoshen WANG ; Xingliu WANG ; Hao ZHU ; Zongkai ZHOU ; Maoying LAN ; Hong GE
Chinese Journal of Radiation Oncology 2022;31(1):49-54
Objective:To propose an automatic planning approach for Eclipse15.6 planning system based on Eclipse scripting application programming interface (ESAPI) and evaluate its clinical application.Methods:20 patients with nasopharyngeal carcinoma and 20 cases of rectal cancer were selected in the clinical planning. The developed automatic planning script SmartPlan and RapidPlan were used for automatic planning and dosimetric parameters were compared with manual planning. The differences were compared between two groups by using Wilcoxon signed rank test. Results:The dosimetric results of automatic and manual plans could meet clinical requirements. There was no significant difference in target coverage in nasopharyngeal carcinoma planning between two groups ( P>0.05), and automatic plans were superior to manual plans in organs at risk sparing ( P<0.05). Except for the homogeneity index of PTV and the maximum dose of bowel in rectal cancer plans, the other dosimetric parameters of the automatic plans were better than those of the manual plans (all P<0.05). Conclusions:Compared with the manual plans, the automatic plans have the same or similar target coverage, similar or better protection of organs at risk, and more convenient implementation. The developed SmartPlan based on ESAPI has clinical feasibility and effectiveness.