2.Simultaneous Determination of Sodium Glycerophosphate and Phosphoric Acid in Concentrated Divitamins and Sodium Phosphate Syrup by Quantitative 31P-Nuclear Magnetic Resonance
Xiang-Tu TU ; Jun LI ; Hong LEI ; Ling-Ping XU ; Mao-Fa ZENG
Chinese Journal of Analytical Chemistry 2024;52(7):1020-1027
A 31P-quantitative nuclear magnetic resonance(qNMR)method was established for simultaneous determination of sodium α-glycerophosphate,sodium β-glycerophosphate and phosphoric acid in concentrated divitamins and sodium phosphate syrup.The qNMR experimental conditions were optimized,including hexamethylphosphoramide as internal standard,20%deuterium oxide solution as solvent,zgig pulse sequence,delay time of 30 s,and scan number of 64.The 31P-NMR peaks atδ29.80 of hexamethylphosphoramide,δ0.69 of sodiumα-glycerophosphate,δ0.17 of sodiumβ-glycerophosphate andδ0.03 of phosphoric acid were chosen as the quantitative peaks(pH of the test solution was around 4.8).Method validation was performed in terms of precision(Relative standard deviation less than 0.6%),linearity(Correlative coefficient greater than 0.999),limit of detection(23.58 μg/mL for sodium glycerophosphate and 11.61 μg/mL for phosphoric acid)and limit of quantitation(78.60 μg/mL for sodium glycerophosphate and 38.70 μg/mL for phosphoric acid).The recoveries were 99.8%?103.2%,and relative standard deviations were 0.41%?1.98%.The results showed that the reliability of 31P-qNMR method were suitable for its intended use.Seven batches of concentrated divitamins and sodium phosphate syrups were tested by the established method,of which the total phosphorus content was consistent with that of colorimetry method,but the content of sodium glycerophosphate(Sum ofαtype andβtype)was relatively low,about 82%of the labeled amount.The content of phosphoric acid was high.This method simplified sample pretreatment and had high specificity,and was more suitable for determination and quality control of concentrated divitamins and sodium phosphate syrup.
3.Clinical application of reverse radial hypothenar flap for finger soft tissue defect.
You-Mao ZHENG ; Fa-Yun ZHANG ; Li-Zhi WU ; Zeng-Tao WANG ; Cheng WANG ; Li-Qi YI ; Zhi-Lin ZHAO
Chinese Journal of Plastic Surgery 2011;27(2):92-95
OBJECTIVETo investigate the therapeutic effect of reverse radial hypothenar flap for finger soft tissue defect.
METHODSFrom Mar. 2006 to Mar. 2010, 13 cases (14 fingers) with finger soft tissue defects were treated with reverse radial hypothenar flaps pedicled with ulnar palmar digital artery of little finger. The defects were 1.9 cm x 1.5 cm -4.0 cm x 2.0 cm in size. The flap size ranged from 1.5 cm x 2.0 cm to 4.0 cm x 2.0 cm.
RESULTSAll the flaps survived completely with primary healing both in donor and recipient area. 12 cases (13 fingers) were followed up for 1-3 years. The flaps color was similar to the unaffected fingers. Cicatricial contracture happened in one case due to contracture of palmar fascia. The two-point discrimination distance on flap was 3.2-5.3mm. The active and passive movement of finger joints was evaluated as excellent in 12 fingers, good in one finger. There was no complaint about the feeling at the donor site. Two months after operation, all patients could go back to work.
CONCLUSIONSThe reverse radial hypothenar flap is very suitable for finger soft tissue defect with less morbidity to donor site.
Adolescent ; Adult ; Female ; Finger Injuries ; surgery ; Follow-Up Studies ; Humans ; Male ; Soft Tissue Injuries ; surgery ; Surgical Flaps ; Young Adult