1.Inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid vessel wall volume measurements on three-dimensional ultrasonography
Chun Wai CHAN ; Sze Chai Christy CHOW ; Man Hei KWOK ; Ka Ching Tiffany NGAN ; Tsun Hei OR ; Simon Takadiyi GUNDA ; Michael YING
Ultrasonography 2023;42(2):214-226
Purpose:
Carotid vessel wall volume (VWV) measurement on three-dimensional ultrasonography (3DUS) outperforms conventional two-dimensional ultrasonography for carotid atherosclerosis evaluation. Although time-saving semi-automated algorithms have been introduced, their clinical availability remains limited due to a lack of validation, particularly an extensive reliability analysis. This study compared inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid VWV measurements on 3DUS.
Methods:
Thirty-one 3DUS volume datasets were prospectively acquired from 20 healthy subjects, aged >18 years, without previous stroke, transient ischemic attack, or cardiovascular disease. Five observers segmented all volume datasets both manually and semi-automatically. The process was repeated five times. Reliability was expressed by the intraclass correlation coefficient, supplemented by the coefficient of variation.
Results:
Carotid VWV measurements using the common carotid artery (CCA) were more reliable than those using the internal carotid artery (ICA) or external carotid artery (ECA) for both manual and semiautomated segmentation (manual segmentation, CCA: inter-observer, 0.935; intra-observer, 0.934 to 0.966; ICA: inter-observer, 0.784; intra-observer, 0.756 to 0.878; ECA: inter-observer, 0.732; intraobserver, 0.919 to 0.962; semi-automated segmentation, CCA: inter-observer, 0.986; intra-observer, 0.954 to 0.993; ICA: inter-observer, 0.977; intra-observer, 0.958 to 0.978; ECA: inter-observer, 0.966; intra-observer, 0.884 to 0.937). Total carotid VWV measurements by manual (inter-observer, 0.922; intra-observer, 0.927 to 0.961) and semi-automated segmentation (inter-observer, 0.987; intra-observer, 0.968 to 0.989) were highly reliable. Semi-automated segmentation showed higher reliability than manual segmentation for both individual and total carotid VWV measurements.
Conclusion
3DUS carotid VWV measurements of the CCA are more reliable than measurements of the ICA and ECA. Total carotid VWV measurements are highly reliable. Semi-automated segmentation has higher reliability than manual segmentation.
2.Stand-Alone Cervical Cages in 2-Level Anterior Interbody Fusion in Cervical Spondylotic Myelopathy: Results from a Minimum 2-Year Follow-up
Eugene Pak Lin NG ; Andrew Siu Leung YIP ; Keith Hay Man WAN ; Michael Siu Hei TSE ; Kam Kwong WONG ; Tik Koon KWOK ; Wing Cheung WONG
Asian Spine Journal 2019;13(2):225-232
STUDY DESIGN: A retrospective review of patients who underwent 2-level anterior cervical discectomy and fusion (ACDF) with standalone polyetheretherketone (PEEK) cages for cervical spondylotic myelopathy (CSM). PURPOSE: To evaluate the efficacy of stand-alone PEEK cage in 2-level cervical interbody fusion for CSM. OVERVIEW OF LITERATURE: ACDF is a standard surgical procedure to treat degenerative disc disease. However, the use of additional anterior plating for 2-level ACDF remains controversial. METHODS: We reviewed outcomes of patients who underwent 2-level ACDF with stand-alone PEEK cages for CSM over a 7-year period (2007–2015) in a regional hospital. Japanese Orthopaedic Association (JOA) score, fusion rate, subsidence rate, cage migration, and cervical alignment by the C2–7 angle as well as the local segmental angle (LSA) of the cervical spine were assessed. RESULTS: In total, 31 patients (mean age, 59 years; range, 36–87 years) underwent 2-level ACDF with a cage-only construct procedure between 2007 and 2015. The minimum follow-up was 24 months; mean follow-up was 51 months. C3–5 fusion was performed in 45%, C4–6 fusion in 32%, and C5–7 fusion in 23%. Mean JOA score improved from 10.1±2.2 to 13.9±2.1 (p<0.01) at the 24-month follow-up. Fusion was achieved in all patients. Subsidence occurred in 22.5% of the cages but was not associated with differences in JOA scores, age, sex, or levels fused. Lordosis of the C2–7 angle and LSA increased after surgery, which were maintained for up to 1 year but subsequently disappeared after 2 years, yet the difference was not statistically significant. No cage migration was noted; two patients developed adjacent segment disease requiring posterior laminoplasty 3 years after ACDF. CONCLUSIONS: The use of a stand-alone PEEK cage in a 2-level cervical interbody fusion achieves satisfactory improvements in both clinical outcomes and fusion.
Animals
;
Asian Continental Ancestry Group
;
Diskectomy
;
Follow-Up Studies
;
Humans
;
Laminoplasty
;
Lordosis
;
Retrospective Studies
;
Spinal Cord Diseases
;
Spine