1.Man power and organization of provincial preventive medicine centers in the northern provinces
Dung Anh Nguyen ; Lien Thi Phuong Nguyen ; Mai Thi Phuong Le ; Tho Thi Nguyen ; Tung Manh Tran
Journal of Preventive Medicine 2008;18(1):21-25
Background: Investment to meet the man power requirements are recognized as urgent; especially to efficiently implement the National Strategy of Preventive Medicine. To strengthen the capability of provincial preventive medicine centers, the Ministry of Health has approved Decision No 05/2006QD-BYT for functions, tasks, authorization and organizational structure of Provincial Preventive Medicine Centers (PPMCs). Objectives: The study was conducted to evaluate the manpower and organization structure of northern PPMCs and provide recommendations for policy makers. Subjects and method: Using the cross-sectional descriptive method, the study covered the preventive medicine centers of 29 northern provinces between Jan to Jun 2007. The information was collected by interviews and self-reported questionnaires. Results:23/29 PPMCs have not met the criteria of man power stated in the Circular 08/2007/TTLB-BYT-BNV. Only 9/29 PPMCs were well organized in accordance with Decision 05/2006/QD-BYT of the Ministry of Health. The average number of staffs in PPMCs was 50+15. Medical staffs accounted for 53%, out of which 21.1% had postgraduate degrees; 32.2% had graduate degrees and 23.3% had been trained in preventive care. Conclusion: To meet the requirements provided by the Decision No05/2006QD-BYT, the man power and training for staffs in PPMCs should be improved and strengthened.
Man power
;
Preventive medicine.
2.A design of simple ventilator control system based on LabVIEW.
Baoqing PEI ; Shengwei XU ; Hui LI ; Deyu LI ; Yidong PEI ; Haixing HE
Chinese Journal of Medical Instrumentation 2011;35(1):50-52
This paper designed a ventilator control system to control proportional valves and motors. It used LabVIEW to control the object mentioned above and design ,validate, evaluate arithmetic, and establish hardware in loop platform. There are two system' s hierarchies. The high layer was used to run non-real time program and the low layer was used to run real time program. The two layers communicated through TCP/IP net. The program can be divided into several modules, which can be expanded and maintained easily. And the harvest in the prototype designing can be seamlessly used to embedded products. From all above, this system was useful in employing OEM products.
Man-Machine Systems
;
Software
;
Software Design
;
Ventilators, Mechanical
3.The testing system for OCP of the digital X-ray machine.
Yan WANG ; Guoming MO ; Juru WANG ; Tao ZHOU ; Jianguo YU
Chinese Journal of Medical Instrumentation 2011;35(5):356-360
In this paper, we designed a testing system for operator control panel of a high-voltage and high-frequency X-ray machine, and an online testing software for functional components, in order to help the testing engineers to improve their work efficiency.
Electricity
;
Equipment Design
;
Man-Machine Systems
;
Radiographic Image Enhancement
;
instrumentation
4.Off-line experiments and analysis of independent brain--computer interface.
Qiang CHEN ; Hu PENG ; Chaohui JIANG ; Huanqing FENG
Journal of Biomedical Engineering 2006;23(3):478-482
In order to study event-related desynchronization (ERD) related to voluntary movement, we designed two experiments. In the first experiment, untrained subjects were required to imagine the action of typing with left or right index finger for about 1 second before real action, whereas they were required to type instantly after instruction in the second experiment. By analyzing spontaneous EEG signals between the instruction and the action, we predicted which finger was used. The prediction accuracy in the first experiment fell from 85% to 71% with the progress of experiment, the average accuracy being 78%, whereas the prediction result was almost random guess in the second experiment. The results demonstrate that (1) ERD patterns are significantly affected by the effective duration of motion imagination, (2) unconscious reduction of this duration can decrease the prediction accuracy. Therefore, when designing subsequent BCI experiments, we should devote our attention to the question of how to keep the effective duration of motion imagination.
Brain
;
physiology
;
Cortical Synchronization
;
Electroencephalography
;
Humans
;
Man-Machine Systems
;
Task Performance and Analysis
;
User-Computer Interface
5.Design and development of a massaging machine for the lumbar vertebrae diseases.
Huai-xing WEN ; Jie YANG ; Hui GUO
Chinese Journal of Medical Instrumentation 2007;31(1):34-39
This paper introduces the designing process of a massaging machine on the basis of Pro/Engineer. The machine has realized the virtual design and movement simulation for the product. It's computer-controlled system has greatly improved the automatic level of the massaging machine which has broad prospects for popularization and application.
Equipment Design
;
Lumbar Vertebrae
;
Man-Machine Systems
;
Massage
;
instrumentation
;
User-Computer Interface
6.Development of practicality of EEG-based brain-computer interface.
Hong LIN ; Qinghua HE ; Qingguang YAN ; Zhengquan FENG ; Baoming WU
Journal of Biomedical Engineering 2010;27(3):702-706
Brain-computer interface (BCI) is a system that can create direct connection between brain activity and external devices. In the past 20 years, important' achievements of research on BCI have been made. Now there are lots of research methods based on electroencephalic signals, and researchers are trying to make the BCI system possess the characteristics of real-time and become more natural and practical. This paper presents an overview of real-time and stimulating way to EEG-based BCI research. Through the discussions on the applications of DSP in BCI system, in signal preprocessing and in algorithm optimization, the high lights in real-time research are pointed out. In the discussions about the way to produce EEG signals in BCI, the researchers suggested that the imaging movement be the most ideal way in that it will reduce the discomfort in stimulation by application of the virtual reality technology in BCI system, thus it will be conducive to improvement in the performance of BCI system.
Brain
;
physiology
;
Communication Aids for Disabled
;
Electroencephalography
;
instrumentation
;
Humans
;
Man-Machine Systems
;
Signal Processing, Computer-Assisted
;
User-Computer Interface
7.Two Cases of Hyperlipoproteinemia.
Suck Whan KIM ; Kyung Ho CHUN ; Eil Soo LEE ; Chong Ju LEE
Korean Journal of Dermatology 1982;20(1):101-107
We report two cases of hyperlipoproteinernia(HLP) with various cutaneous xanthomas. Case 1 was a 12-year-old girl, who had tuberous, tendinous, and plane cutaneous xanthomas and corneal arcus of the left eye. Case 2 was a 40-year-old man, who had tuberous, eruptive, and plane cutaneous xanthomas. Serum lipid and lipoprotein analysis reveoled patterns of Type IIa HLP in case 1 and, of Type IIb HLP, in case 2. They have been treated with diet control and hypolipidemic drugs and are under our continuing medical supervision.
Adult
;
Child
;
Female
;
Humans
;
Hyperlipoproteinemia Type II/diagnosis*
;
Hyperlipoproteinemia Type II/drug therapy*
;
Hypolipidemic Agents/therapeutic use*
;
Lipoproteins
;
Man
;
Xanthomatosis/diagnosis
;
Xanthomatosis/drug therapy
8.Design and implementation of controlling smart car systems using P300 brain-computer interface.
Jinjia WANG ; Chengjie YANG ; Bei HU
Journal of Biomedical Engineering 2013;30(2):223-228
Using human electroencephalogram (EEG) to control external devices in order to achieve a variety of functions has been focus of the field of brain-computer interface (BCI) research. P300 is experiments which stimulate the eye to produce EEG by using letters flashing, and then identify the corresponding letters. In this paper, some improvements based on the P300 experiments were made??. Firstly, the matrix of flashing letters were modified into words which represent a certain sense. Secondly, the BCI2000 procedures were added with the corresponding source code. Thirdly, the smart car systems were designed using the radiofrequency signal. Finally it was realized that the evoked potentials were used to control the state of the smart car.
Adult
;
Automobiles
;
Brain
;
physiology
;
Brain-Computer Interfaces
;
Electroencephalography
;
instrumentation
;
methods
;
Event-Related Potentials, P300
;
Evoked Potentials, Visual
;
Female
;
Humans
;
Male
;
Man-Machine Systems
;
Task Performance and Analysis