1.Soft Copy Digital Mammography.
Korean Journal of Radiology 2005;6(4):206-207
No abstract available.
*Radiographic Image Enhancement
;
Mammography/*methods
;
Humans
2.Key technologies in digital breast tomosynthesis system:theory, design, and optimization.
Mingqiang LI ; Kun MA ; Xi TAO ; Yongbo WANG ; Ji HE ; Ziquan WEI ; Geofeng CHEN ; Sui LI ; Dong ZENG ; Zhaoying BIAN ; Guohui WU ; Shan LIAO ; Jianhua MA
Journal of Southern Medical University 2019;39(2):192-200
OBJECTIVE:
To develop a digital breast tomosynthesis (DBT) imaging system with optimizes imaging chain.
METHODS:
Based on 3D tomography and DBT imaging scanning, we analyzed the methods for projection data correction, geometric correction, projection enhancement, filter modulation, and image reconstruction, and established a hardware testing platform. In the experiment, the standard ACR phantom and high-resolution phantom were used to evaluate the system stability and noise level. The patient projection data of commercial equipment was used to test the effect of the imaging algorithm.
RESULTS:
In the high-resolution phantom study, the line pairs were clear without confusing artifacts in the images reconstructed with the geometric correction parameters. In ACR phantom study, the calcified foci, cysts, and fibrous structures were more clearly defined in the reconstructed images after filtering and modulation. The patient data study showed a high contrast between tissues, and the lesions were more clearly displayed in the reconstructed image.
CONCLUSIONS
This DBT imaging system can be used for mammary tomography with an image quality comparable to that of commercial DBT systems to facilitate imaging diagnosis of breast diseases.
Algorithms
;
Artifacts
;
Breast
;
diagnostic imaging
;
Female
;
Humans
;
Mammography
;
methods
;
Phantoms, Imaging
;
Radiographic Image Enhancement
;
methods
3.Establishment of a deep feature-based classification model for distinguishing benign and malignant breast tumors on full-filed digital mammography.
Cuixia LIANG ; Mingqiang LI ; Zhaoying BIAN ; Wenbing LV ; Dong ZENG ; Jianhua MA
Journal of Southern Medical University 2019;39(1):88-92
OBJECTIVE:
To develop a deep features-based model to classify benign and malignant breast lesions on full- filed digital mammography.
METHODS:
The data of full-filed digital mammography in both craniocaudal view and mediolateral oblique view from 106 patients with breast neoplasms were analyzed. Twenty-three handcrafted features (HCF) were extracted from the images of the breast tumors and a suitable feature set of HCF was selected using -test. The deep features (DF) were extracted from the 3 pre-trained deep learning models, namely AlexNet, VGG16 and GoogLeNet. With abundant breast tumor information from the craniocaudal view and mediolateral oblique view, we combined the two extracted features (DF and HCF) as the two-view features. A multi-classifier model was finally constructed based on the combined HCF and DF sets. The classification ability of different deep learning networks was evaluated.
RESULTS:
Quantitative evaluation results showed that the proposed HCF+DF model outperformed HCF model, and AlexNet produced the best performances among the 3 deep learning models.
CONCLUSIONS
The proposed model that combines DF and HCF sets of breast tumors can effectively distinguish benign and malignant breast lesions on full-filed digital mammography.
Breast Neoplasms
;
classification
;
diagnostic imaging
;
Deep Learning
;
Diagnosis, Computer-Assisted
;
methods
;
Female
;
Humans
;
Mammography
;
methods
4.Detection of multiple clustered microcalcifications by mammography following breast-conserving surgery.
Juan LI ; Min BAO ; Hui-mian XU ; Zhen-ning WANG
Chinese Medical Journal 2010;123(8):1097-1098
Adult
;
Breast Neoplasms
;
diagnosis
;
surgery
;
Calcinosis
;
diagnosis
;
diagnostic imaging
;
Female
;
Humans
;
Mammography
;
methods
;
Mastectomy, Segmental
5.Mammographic Mass Detection Using a Mass Template.
Serhat OZEKES ; Onur OSMAN ; A Yilmaz CAMURCU
Korean Journal of Radiology 2005;6(4):221-228
OBJECTIVE: The purpose of this study was to develop a new method for automated mass detection in digital mammographic images using templates. MATERIALS AND METHODS: Masses were detected using a two steps process. First, the pixels in the mammogram images were scanned in 8 directions, and regions of interest (ROI) were identified using various thresholds. Then, a mass template was used to categorize the ROI as true masses or non-masses based on their morphologies. Each pixel of a ROI was scanned with a mass template to determine whether there was a shape (part of a ROI) similar to the mass in the template. The similarity was controlled using two thresholds. If a shape was detected, then the coordinates of the shape were recorded as part of a true mass. To test the system's efficiency, we applied this process to 52 mammogram images from the Mammographic Image Analysis Society (MIAS) database. RESULTS: Three hundred and thirty-two ROI were identified using the ROI specification methods. These ROI were classified using three templates whose diameters were 10, 20 and 30 pixels. The results of this experiment showed that using the templates with these diameters achieved sensitivities of 93%, 90% and 81% with 1.3, 0.7 and 0.33 false positives per image respectively. CONCLUSION: These results indicate that the detection performance of this template based algorithm is satisfactory, and may improve the performance of computer-aided analysis of mammographic images and early diagnosis of mammographic masses.
Sensitivity and Specificity
;
Radiographic Image Enhancement
;
Mammography/*methods
;
Humans
;
False Positive Reactions
;
Automation
;
Algorithms
6.Screen-Film Mammography and Soft-Copy Full-Field Digital Mammography: Comparison in the Patients with Microcalcifications.
Hye Seong KIM ; Boo Kyung HAN ; Ki Seok CHOO ; Yong Hwan JEON ; Jung Han KIM ; Yeon Hyeon CHOE
Korean Journal of Radiology 2005;6(4):214-220
OBJECTIVE: We wanted to compare the ability of screen-film mammography (SFM) and soft-copy full-field digital mammography (s-FFDM) on two different monitors to detect and characterize microcalcifications. MATERIALS AND METHODS: The images of 40 patients with microcalcifications (three patients had malignant lesion and 37 patients had benign lesion), who underwent both SFM and FFDM at an interval of less than six months, were independently evaluated by three readers. Three reading sessions were undertaken for SFM and for FFDM on a mammography-dedicated review workstation (RWS, 2K x 2.5K), and for FFDM on a high-resolution PACS monitor (1.7K x 2.3K). The image quality, breast composition and the number and conspicuity of the microcalcifications were evaluated using a three-point rating method, and the mammographic assessment was classified into 4 categories (normal, benign, low concern and moderate to great concern). RESULTS: The image quality, the number and conspicuity of the microcalcifications by s-FFDM (on the RWS, PACS and both) were superior to those by SFM in 85.0%, 80.0% and 52.5% of the cases, respectively (p < 0.01), and those by the s-FFDM on the two different monitors were similar in 15.0%, 12.5% and 35.0% of the cases, respectively (p > 0.01). The mammographic assessment category for the microcalcifications in the three reading sessions was similar. CONCLUSION: s-FFDM gives a superior image quality to SFM and it is better at evaluating microcalcifications. In addition, s-FFDM with the PACS monitor is comparable to s-FFDM with the RWS for evaluating microcalcifications.
*Radiographic Image Enhancement
;
Mammography/*methods
;
Humans
;
Female
;
Calcinosis/*radiography
;
Breast Diseases/*radiography
7.Advances in research on automatic exposure control of mammography system.
Guoyi WANG ; Chengfu YE ; Haiming WU ; Tainfu WANG ; Hong ZHANG
Journal of Biomedical Engineering 2014;31(6):1394-1399
Mammography imaging is one of the most demanding imaging modalities from the point of view of the bal- ance between image quality (the visibility of small size and/or low contrast structures) and dose (screening of many asymptomatic people). Therefore, since the introduction of the first dedicated mammographic units, many efforts have been directed to seek the best possible image quality while minimizing patient dose. The performance of auto- matic exposure control (AEC) is the manifestation of this demand. The theory of AEC includes exposure detection and optimization and also involves some accomplished methodology. This review presents the development and present situa- tion of spectrum optimization, detector evolution, and the way how to accomplish and evaluate AEC methods.
Humans
;
Mammography
;
methods
;
Phantoms, Imaging
;
Radiation Dosage
;
Radiographic Image Interpretation, Computer-Assisted
8.Automated Breast Ultrasound Screening for Dense Breasts
Sung Hun KIM ; Hak Hee KIM ; Woo Kyung MOON
Korean Journal of Radiology 2020;21(1):15-24
Mammography is the primary screening method for breast cancers. However, the sensitivity of mammographic screening is lower for dense breasts, which are an independent risk factor for breast cancers. Automated breast ultrasound (ABUS) is used as an adjunct to mammography for screening breast cancers in asymptomatic women with dense breasts. It is an effective screening modality with diagnostic accuracy comparable to that of handheld ultrasound (HHUS). Radiologists should be familiar with the unique display mode, imaging features, and artifacts in ABUS, which differ from those in HHUS. The purpose of this study was to provide a comprehensive review of the clinical significance of dense breasts and ABUS screening, describe the unique features of ABUS, and introduce the method of use and interpretation of ABUS.]]>
Artifacts
;
Breast Neoplasms
;
Breast
;
Early Detection of Cancer
;
Female
;
Humans
;
Mammography
;
Mass Screening
;
Methods
;
Risk Factors
;
Ultrasonography
9.Medical auditing of whole-breast screening ultrasonography.
Ultrasonography 2017;36(3):198-203
Since breast ultrasonography (US) has been used as an adjunctive screening modality in women with dense breasts, the need has arisen to evaluate and monitor its possible harm and benefits in comparison with other screening modalities such as mammography. Recently, the fifth edition of the Breast Imaging Reporting and Data System published by the American College of Radiology has suggested auditing methods for screening breast US. However, the method proposed therein is slightly different from how diagnostic performance was calculated in previous studies on screening breast US. In this article, the background and core aspects of medical audits of breast cancer screening will be reviewed to provide an introduction to the medical auditing of screening breast US, with the goal of helping radiologists to understand and identify potential ways to improve outcomes.
Breast
;
Breast Neoplasms
;
Female
;
Humans
;
Information Systems
;
Mammography
;
Mass Screening*
;
Medical Audit*
;
Methods
;
Ultrasonography*
;
Ultrasonography, Mammary
10.Comparison of the Diagnostic Values of Dynamic Enhanced Magnetic Resonance Imaging,Digital Breast Tomosynthesis,and Digital Mammography for Early Breast Cancer.
A Qiao XU ; Xiao Bo WENG ; Jing ZHENG ; Zhi Qing LI ; Xiao Ling WANG ; Sheng Jian ZHANG
Acta Academiae Medicinae Sinicae 2019;41(5):667-672
Objective To compare the values of dynamic enhanced magnetic resonance imaging(DCE-MRI),digital breast tomosynthesis(DBT),and digital mammography(DM)in the early detection and diagnosis of breast cancer.Methods We retrospectively analyzed the clinical and imaging data of 65 cases with early breast cancer confirmed by surgical pathology from June 2017 to December 2018.All patients underwent breast DCE-MRI,DM and DBT before surgery.The receiver operating characteristic(ROC)curves were drawn,with the pathological results as the gold standard,to evaluate the diagnostic performance of different examination methods.The areas under ROC curves(AUCs)were compared using test.The differences among DCE-MRI,DBT and DM in detecting early breast cancer were compared using chi-square test in terms of positive rates,accuracy,sensitivity,and specificity.Pearson correlation analysis was performed to assess the accuracy of these imaging methods in detecting the size of early breast cancer.Results The AUCs of DCE-MRI,DBT,and DM based on the BI-RADS classification for early diagnosis of breast cancer were 0.910,0.832,and 0.700,respectively(=2.132,=0.001);the sensitivity of DCE-MRI,DBT,and DM for early breast cancer was 92.3%,70.8%,and 52.5%,the specificity was 65.0%,85.0%,and 79.3%,and the accuracy was 83.1%,70.8%,and 50.8%,indicating that DCE-MRI(=15.330,=0.0001) and DBT(=5.450,=0.020) had significantly higher diagnostic accuracy than DM.The measurement results of DM,DBT,and DCE-MRI were positively correlated with the pathological measurements(=0.781,=0.847,=0.946;all <0.01). Conclusions DCE-MRI and DBT have higher positive rates and accuracies than DM in detecting early breast cancer.Medical institutions where DCE-MRI is still not available can use DBT to improve the early detection of breast cancer.
Breast
;
diagnostic imaging
;
Breast Neoplasms
;
diagnostic imaging
;
Female
;
Humans
;
Magnetic Resonance Imaging
;
Mammography
;
methods
;
Retrospective Studies