1.Grounding technique for the safety and noise rejection of medical imaging equipments.
Feng-tan HAN ; Zhaong HUA ; Le-min HE ; Xian-ying QI ; Feng TANG
Chinese Journal of Medical Instrumentation 2006;30(1):55-42
Grounding technique is very important to ensure the human safety, imaging devices' safety and the devices' reliable running. This paper expatriates the principles of the grounding safety, interference rejection earth, and the grounding modes and the mode selection for each imaging devices and equipments, and related grounding requirements.
Equipment Safety
;
methods
;
Magnetic Resonance Imaging
;
instrumentation
2.The development of fiber-based MR imaging technique.
Chinese Journal of Medical Instrumentation 2013;37(2):116-118
It has been several decades since the Magnetic Resonance Imaging was introduced to the public as a measure of clinical imaging diagnosis in the 1980's. Time has witnessed increasingly advanced structure and imaging technique. Now, fiber is used as the media to transmit signals of MRI. Manufacturers are competing to release new and creative imaging technique to customers, which has made it faster, more accurate and more convenient for MR imaging. This article briefly introduces latest MR devices with fiber transmission and summarizes their hardwares and softwares so as to provide reference to hospitals that will purchase these devices.
Magnetic Resonance Imaging
;
instrumentation
;
methods
;
Software
3.Mechanical Shimming Method and Implementation for Permanent Magnet of MRI System.
Chinese Journal of Medical Instrumentation 2015;39(3):170-172
A mechanical shimming method and device for permanent magnet of MRI system has been developed to meet its stringent homogeneity requirement without time-consuming passive shimming on site, installation and adjustment efficiency has been increased.
Magnetic Resonance Imaging
;
instrumentation
;
methods
;
Magnets
4.The impact of prime parameters of MR RF-subsystem on functionality.
Chinese Journal of Medical Instrumentation 2012;36(1):12-14
In this article, an introduction is given on the structure of RF subsystem, its main parameters and impact on the performance of MRI and RF techniques and its development. Furthermore, pivotal parameters provided by different suppliers are quoted and compared in functionality aspect.
Magnetic Resonance Imaging
;
instrumentation
;
methods
;
Radio Waves
5.Safety analysis and test advices of superconductive magnet.
Chinese Journal of Medical Instrumentation 2013;37(1):51-56
Based on the current GB standard and IEC standard, some unique security risk points of the superconductive magnet were discussed and pointed, some security eigenvalue of widely used MRI were calculated, method and technology of the quench risk & protection were focused. Currently during the type test of superconductive MRI, the national standards and industry standards have not included items focus on superconductive magnet particularly, so this paper gives some recommended discussing and hopes to improve and enhance the future standard. Because superconductive MRI uses a large number of helium gas which is very short in China and if quenching, helium will evaporate quickly, so the helium recycling are also discussed.
Equipment Safety
;
Magnetic Resonance Imaging
;
instrumentation
;
Magnets
6.Comparative analysis of calculation methods of coil sensitivity in parallel MRI.
Yiming LI ; Bin LI ; Mingli QIAN ; Longchen WANG
Chinese Journal of Medical Instrumentation 2013;37(1):14-17
Calculation methods of coil sensitivity in parallel MRI were elaborated, compared and analyzed.
Algorithms
;
Magnetic Resonance Imaging
;
instrumentation
;
methods
7.Common malfunctions shooting to MRI OPEN MARK II.
Chinese Journal of Medical Instrumentation 2012;36(6):459-460
This paper introduces and analyses common malfunctions of MRI OPNE MARK II to provide reference for maintenance and preservation of the machine.
Equipment Failure
;
Magnetic Resonance Imaging
;
instrumentation
;
Maintenance
8.Low-field MRI: a quick scan based on the large field of view.
Changqing DING ; Ruofeng XU ; Guangtong XIE ; Chengbin ZHANG ; Chen WANG
Chinese Journal of Medical Instrumentation 2012;36(3):225-226
To optimize the configuration of the conventional SE and FSE sequence parameters in low field MRI. With the combination of larger vision, relatively thinner slice thickness, small number of excitation (NEX = 1 or 2), the signal-to-noise ration and the spatial resolution on follow-up images are moderate, the scan time is significantly shorter along with fewer motion artifacts, the check success rate is improved.
Equipment Design
;
Magnetic Resonance Imaging
;
instrumentation
;
methods
9.MRI compatibility of deep brain stimulator.
Chinese Journal of Medical Instrumentation 2013;37(4):244-247
Deep brain stimulation (DBS) therapy develops rapidly in clinical application. The structures of deep brain stimulator and magnetic resonance imaging (MRI) equipment are introduced, the interactions are analyzed, and the two compatible problems of radio frequency (RF) heating and imaging artifact are summarized in this paper.
Artifacts
;
Deep Brain Stimulation
;
instrumentation
;
Humans
;
Magnetic Resonance Imaging
;
instrumentation
10.The discussion of superconducting MRI magnet transformation without LHe.
Chinese Journal of Medical Instrumentation 2014;38(1):23-25
In this paper, from the current situation of the domestic use of superconducting MRI, on liquid helium supply and demand crisis in the market, the significance of the transformation without LHe of the superconducting MRI magnet was explained, and according to the enterprise's production process, a number of operating without liquid helium transformation practice and ideas were raised, important value orientation for the domestic manufacture and use of superconducting MRI was provided.
Equipment Design
;
Magnetic Resonance Imaging
;
instrumentation
;
Magnetics
;
instrumentation