1.Prevalence of complications associated with polymer-based alloplastic materials in nasal dorsal augmentation: a systematic review and meta-analysis
Seied Omid KEYHAN ; Shaqayeq RAMEZANZADE ; Reza Golvardi YAZDI ; Mohammad Amin VALIPOUR ; Hamid Reza FALLAHI ; Madjid SHAKIBA ; Mahsa AEINEHVAND
Maxillofacial Plastic and Reconstructive Surgery 2022;44(1):17-
Background:
Various techniques with different grafts and implants have been proposed to establish a smooth and symmetric nasal dorsum with adequate function. Broadly, two categories of materials have been used in this regard: alloplastic implant materials and autograft materials. The aim of these meta-analyses is to explore the incidence of complications after dorsum augmentation surgery using alloplastic materials.
Materials and methods:
After duplication removal 491 papers remained that title and abstract were assessed for eligibility. Regarding the study type, 27 observational studies were included, 21 retrospective and 6 prospective case series. A total of 3803 cases were enrolled in this systematic review and meta-analysis.ResultTwenty-seven articles reported on complications and outcomes of dorsal augmentation rhinoplasty with synthetic materials. In a random-effects model, the weighted mean percentage was 2.75% (95% CI 1.61 to 4.17%). the weighted mean percentage were 1.91% (95% CI 0.77 to 3.54%), 0.72% (95% CI 0.316 to 1.31%), and 0.78% (95% CI 0.43 to 1.24%) respectively.
Conclusion
The widely used alloplasts were expanded polytetrafluoroethylene (ePTFE), high-density polyethylene, and silicone. The total rates for complications, infection, deviation, irregularity, hematoma, extrusion, and overcorrection were 2.75%, 1.91%, 0.72%, 0.70%, 0.78%, and 0.49%, respectively. The revision rate, based on the random effects model, was 6.40% with 95%CI (3.84 to 9.57).
2.Magnetic Resonance Imaging Features of Adenosis in the Breast.
Masoumeh GITY ; Ali ARABKHERADMAND ; Elham TAHERI ; Madjid SHAKIBA ; Yassaman KHADEMI ; Bijan BIJAN ; Mohammad Salehi SADAGHIANI ; Amir Hossein JALALI
Journal of Breast Cancer 2015;18(2):187-194
PURPOSE: Adenosis lesions of the breast, including sclerosing adenosis and adenosis tumors, are a group of benign proliferative disorders that may mimic the features of malignancy on imaging. In this study, we aim to describe the features of breast adenosis lesions with suspicious or borderline findings on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). METHODS: In our database, we identified 49 pathologically proven breast adenosis lesions for which the final assessment of the breast MRI report was classified as either category 4 (n=45) or category 5 (n=4), according to the Breast Imaging Reporting and Data System (BI-RADS) published by the American College of Radiology (ACR). The lesions had a final diagnosis of either pure adenosis (n=33, 67.3%) or mixed adenosis associated with other benign pathologies (n=16, 32.7%). RESULTS: Of the 49 adenosis lesions detected on DCE-MRI, 32 (65.3%) appeared as enhancing masses, 16 (32.7%) as nonmass enhancements, and one (2.1%) as a tiny enhancing focus. Analysis of the enhancing masses based on the ACR BI-RADS lexicon revealed that among the mass descriptors, the most common features were irregular shape in 12 (37.5%), noncircumscribed margin in 20 (62.5%), heterogeneous internal pattern in 16 (50.0%), rapid initial enhancement in 32 (100.0%), and wash-out delayed en-hancement pattern in 21 (65.6%). Of the 16 nonmass enhancing lesions, the most common descriptors included focal distribution in seven (43.8%), segmental distribution in six (37.5%), clumped internal pattern in nine (56.3%), rapid initial enhancement in 16 (100.0%), and wash-out delayed enhancement pattern in eight (50.0%). CONCLUSION: Adenosis lesions of the breast may appear suspicious on breast MRI. Awareness of these suspi-cious-appearing features would be helpful in obviating unnecessary breast biopsies.
Biopsy
;
Breast*
;
Diagnosis
;
Fibrocystic Breast Disease
;
Information Systems
;
Magnetic Resonance Imaging*
;
Pathology
;
Subject Headings
3.Erratum: Magnetic Resonance Imaging Features of Adenosis in the Breast.
Masoumeh GITY ; Ali ARABKHERADMAND ; Elham TAHERI ; Madjid SHAKIBA ; Yassaman KHADEMI ; Bijan BIJAN ; Mohammad Salehi SADAGHIANI ; Amir Hossein JALALI
Journal of Breast Cancer 2017;20(1):116-116
No abstract available.
Breast*
;
Magnetic Resonance Imaging*