2.An Unexpected Cause of Trauma-related Myocardial Infarction: Multimodality Assessment of Right Coronary Artery Dissection.
Pei Ing NGAM ; Ching Ching ONG ; Christopher Cy KOO ; Poay Huan LOH ; Lynette Ma LOO ; Lynette Ls TEO
Annals of the Academy of Medicine, Singapore 2018;47(7):269-271
Adult
;
Aneurysm, Dissecting
;
diagnosis
;
etiology
;
Computed Tomography Angiography
;
methods
;
Conservative Treatment
;
methods
;
Coronary Angiography
;
methods
;
Coronary Vessels
;
diagnostic imaging
;
pathology
;
Electrocardiography
;
methods
;
Heart Injuries
;
complications
;
Humans
;
Magnetic Resonance Imaging, Cine
;
methods
;
Male
;
Multimodal Imaging
;
methods
;
Myocardial Infarction
;
diagnosis
;
etiology
;
therapy
;
Treatment Outcome
;
Wounds, Nonpenetrating
;
complications
4.Magnetic Resonance Elastography and Diffusion Weighted Imaging in the Evaluation of Hepatic Fibrosis in Chronic Hepatitis B.
Tiffany P HENNEDIGE ; Gang WANG ; Fiona P LEUNG ; Hind S ALSAIF ; Lynette LS TEO ; Seng Gee LIM ; Aileen WEE ; Sudhakar K VENKATESH
Gut and Liver 2017;11(3):401-408
BACKGROUND/AIMS: Comparison of the accuracy of magnetic resonance elastography (MRE) and diffusion weighted imaging (DWI) for the diagnosis of liver fibrosis in patients with chronic hepatitis B (CHB). METHODS: In this retrospective analysis, we investigated 63 patients with CHB and liver fibrosis. DWI was performed with both breath-hold (DWI-BH) and free-breathing (DWI-FB) sequences (b=0, 500). The mean liver stiffness and apparent diffusion coefficient (ADC) were calculated by drawing regions of interest maps. Fibrosis staging according to the METAVIR system was independently performed by an experienced pathologist. A receiver operating curve (ROC) analysis was conducted to determine the accuracy of MRE, DWI-BH and DWI-FB in the detection and stratification of liver fibrosis. The performance of the detection of significant fibrosis (≥F2), advanced fibrosis (≥F3), and cirrhosis (F4) was also evaluated by comparing areas under the ROC. RESULTS: There was a moderate and significantly negative correlation between the ADC values and liver stiffness. The accuracies for the detection of ≥F2/≥F3/F4 stage fibrosis with DWI-FB, DWI-BH and MRE were 0.84/0.76/0.72, 0.72/0.83/0.79 and 0.99/0.99/0.98, respectively. The performance of MRE was significantly better than DWI-FB and DWI-BH. There were no significant differences between the performance of DWI-FB and DWI-BH. CONCLUSIONS: MRE is more accurate than DWI for the detection and stratification of liver fibrosis in CHB.
Diagnosis
;
Diffusion*
;
Elasticity Imaging Techniques*
;
Fibrosis*
;
Hepatitis B, Chronic*
;
Hepatitis, Chronic*
;
Humans
;
Liver
;
Liver Cirrhosis
;
Retrospective Studies
5.Corrigendum: Magnetic Resonance Elastography and Diffusion Weighted Imaging in the Evaluation of Hepatic Fibrosis in Chronic Hepatitis B
Tiffany P. HENNEDIGE ; Gang WANG ; Fiona P. LEUNG ; Hind S. ALSAIF ; Lynette LS TEO ; Seng Gee LIM ; Aileen WEE ; Sudhakar K. VENKATESH
Gut and Liver 2020;14(4):532-532