1.Recent research progress on lumbar sagittal curvature
Orthopedic Journal of China 2006;0(05):-
For the past few years,lumbar sagittal curvature is increasingly recognized as a critical parameter in spine surgery.It has become evident that good clinical outcome in the spine surgery requires proper lumbar sagittal curvature.With the development of recognization of lumbar sagittal curvature,many new ways and views have been found in measure and recovery sagittal alignments.The purpose of this manuscript is to provide a review of the past year's published literature involving lumbar sagittal curvature.
2.Individualized localization of the lumbar pedicle screw entrance points by vertebral plate borderline
Lun TAN ; Chao WU ; Xiaozhong LUO
Orthopedic Journal of China 2006;0(03):-
[Objective] To investigate the effectivity and reliability of individualized method to localize the entrance point of the lumbar pedicle screws by vertebral plate borderline.[Methods]Four vertebra specimen were taken the X-ray film of anterior-posterior views as the center of L2.On the X-ray film,the distance between the centre-point of the pedicle to the lateral and superior margins of the vertebral plate were measured,after applied barium at the centre-point of the pedicle,the specimen were taken the X-ray film once more,the relation of the barium to the centre-point of the pedicle was measured;the distance between the centre-point of the pedicle to the lateral and superior margins of the vertebral plate were measured on the normal lumbar X-ray film in 107 cases,the data in different sex and different projection 's center were compared;the method were applied to 40 patients of lumbar pedicle internal fixation,the information in hospital were reviewed to 30 patients of the lumbar pedicle screw localization by transverse process and transverse process.[Results]All(except L5)of lumbar plate borderline were displayed clear in the experiment,accurate rate of setpoint to be 92.5%.The principal X-ray affected scarely to the relation of the pedicle with the plate borderline of nearby two segment,but affected obviously far from three segment on the normal lumbar X-ray film;the accurate rate of one time 's setpoint in clinical application was 96%,average operation 's time being 96 minute,average lose blood being 212 ml,transverse articular process 's group showed significant difference.[Conclusion]Individualized localization of the lumbar pedicle screw entrance points by vertebral plate borderline is one of feasible method,displayed less trauma and accurate rate highly in the clinical application.
3.Radiographic study and clinical significance about sagittal plane curves in the adjacent segments of the thoracic and lumbar spine
Orthopedic Journal of China 2006;0(15):-
[Objective]To study the anatomy about the sagittal plane curves of the adjacent segments of the thoracic and lumbar spine on the radiographs of standing position,in order to provide anatomical evidence for clinical operation. [Methods]Seventy-five standing posture radiographs about normal adult were obtained,the sagittal plane curves of the adjacent segments of the thoracic and lumbar spine were obtained by measuring the angles between perpendicular of adjacent superior end plate.The normal value and rule about sagiital plane curves were determined by statistical method.Fifty patients received operation according to these measures.The Cobb's angle of sagittal plane(T12-S1) at 0,3,12 months postoperatively,Denis scores at 12 months postoperatively and the cases in which breaking or loosening internal fixation occurred at 12 months postoperatively were recorded.[Results]The 95% confidence interval of about sagittal plane curves was obtained.There was no statistical significance for sex and age.It would improve function postoperatively and decrease the broken or loosened internal fixation.[Conclusion]It's important to recover the Cobb's angle in the short segmental internal fixation with pedicle screws through posterior approach.
4.Percutaneous locking compression plate and interlocking intramedullary nail:a comparison in the treatment of distal tibia shaft fracture
Chao WU ; Lun TAN ; Xiaozhong LUO
Orthopedic Journal of China 2006;0(08):-
[Objective]To evaluate the radiographic and clinical results of locking compression plate and interlocking intramedullary nail in the treatment of distal tibial shaft fracture(4 to 11cm proximal to tibiotalar joint).[Method]A total of 65 cases of distal tibia shaft fractures were retrospectively reviewed from 2003 to 2007.Thirty-seven cases were treated with locking compression plate as group A,and 28 cases were treated with interlocking intramedullary nail as group B.According to AO classification system,32 cases were type A,12 were type B,21 were type C.[Result]All cases were followed up for 12-24 months(mean,16.5 months).Five cases were found delayed or nonunion,with 1 case in group A and 4 cases in group B.One case in group A and 2 cases in group B were found developed deep infection.Two cases in group A and 8 cases in group B received second operation.The good-to-excellent rates of ankle joint function were 91.9% in group A and 71.4% in group B.The good-to-excellent rates of knee joint function were 97.3% in group A and 78.6% in group B.[Conclusion]Distal tibial shaft fracture could be treated successfully with either percutaneous plates or intramedullary nails.Percutaneous locking plate is better than intramedullary nail in aspect of prevention of delayed union,malunion and second operation.
5.A case series of dermatological emergencies – Erythroderma
The Medical Journal of Malaysia 2017;72(2):141-143
Erythroderma can be life-threatening, primarily because of
its metabolic burden and complications. It is mandatory to
establish its etiopathology in order to facilitate precise and
definitive management. This disorder may be the
morphologic presentation of a variety of cutaneous and
systemic diseases. Detailed history and thorough work-up is
therefore essential. Management of erythroderma involves
multi-disciplines with progress monitoring especially on
signs and symptoms suggestive of acute skin failure
induced complications. Early diagnosis and referral of
erythroderma to centres with dermatological services is
crucial and will directly affect the outcome of the patients.
Dermatitis, Exfoliative
6.Analysis of a survey result of Keshan disease in Zhangjiakou City of Hebei Province in 2010
Pei-lun, HUA ; Zhong-xiang, WANG ; Jie, TAN
Chinese Journal of Endemiology 2013;32(4):436-438
Objective To study Keshan disease and its developmental trend in Zhangjiakou City in 2010 and to provide a scientific basis for further prevention of the disease.Methods From the eight diseased counties of Zhangjiakou City,five diseased countries were selected; in each diseased county a diseased village was selected as the clinical investigating point.Physical examination and Electrocardiography (ECG) tracings were carried out to suspicious patients with Keshan disease.Suspected heart enlargement,and ECG abnormalities were taken anteroposterior chest X-ray to measure the cardiothoracic ratio.Results A total of 2519 people were examined,16 cases were diagnosed as chronic Keshan disease,79 as latent Keshan disease,and the detection rate was 0.64% (16/2519) and 3.14%(79/2519),respectively.Total of 2519 ECG tracings were taken,and electrocardiogram abnormalities were 268 cases,with a abnormal rate 10.64%,and most of them were complete right bundle branch block[accounted for 17.16% (46/268)].Totally 94 cases of anteroposterior chest X-ray films were taken and 42 cases were cardiac enlargement,with a detection rate 44.68%.The numbers of mild,moderate and severe cases were 20,12 and 10,respectively,and the constituent ratio was 47.62% (20/42),28.57% (12/42),23.81% (10/42),respectively.Conclusions The incidence of Keshan disease in Zhangjiakou City is relatively low,and the condition is stable.But monitoring and comprehensive prevention and control measure still should be strengthened.
7.Computer-assisted design of scaphoid reconstruction:individualized percutaneous cannulated screw fixation
Xu LIN ; Jun ZENG ; Yong GUO ; Lun TAN
Chinese Journal of Tissue Engineering Research 2014;(44):7178-7182
BACKGROUND:Individualized percutaneous cannulated screws fixation with the help of computer-assisted design and cast immobilization are common methods for treating nondisplaced wrist scaphoid fracture. However their clinical outcomes are stil unclear. <br> OBJECTIVE:To compare the clinical results of individualized percutaneous cannulated screws fixation with the help of computer-assisted design and cast immobilization for treatment of Herbert type Ib scaphoid fracture. <br> METHODS:A total of 36 patients with fresh Herbert type Ib scaphoid fracture were divided into two groups, individualized percutaneous cannulated screws fixation with the help of computer-assisted design group (screw group, 20 cases) and cast immobilization group (cast group, 16 cases). In the screw group, cannulated screws were inserted using 0.8 mm kirschner wires from scaphoid tuberosity based on the preoperative individualization fixation parameters. The direction of the wires was guided under C-arms and Herbert screws were percutaneously immobilized after fluoroscopy. In the cast group, radial deviation and palmar flexion plaster casts were immobilized for 3 months. The time of bone union, rate of bone nonunion, time return to work, wrist motion were recorded and compared in the fol ow-up. <br> RESULTS AND CONCLUSION:Al cases were fol owed for 10-24 months. Al patients in the screw fixation group and 13 out of 16 patients in the cast group achieved bone union. The average time of bone union of the two groups was 6 weeks and 14 weeks respectively (P<0.001). The time of returning to work was 7.6 weeks and 16.8 weeks respectively, with significant differences between the two groups (P<0.001). The range of motion of screw fixation group at the final fol ow-up was 96.4°-114.4°, average 104.4°, which was significantly higher than that in the cast group (66.4°-104.2°, average 94.2°;P<0.001). Individualized percutaneous cannulated screws fixation with the help of computer-assisted design can provide mini-invasion, high accuracy and good reproducibility, has better results than cast immobilization in the treatment of Herbert typeⅠscaphoid fractures.
8.Photoelectric navigation-aided percutaneous pedicle screw placement versus traditional open posterior pedicle screw fixation for thoracolumbar fractures
Zeli ZHONG ; Shengyu WAN ; Lun TAN ; Xu LIN ; Chao WU
Chinese Journal of Tissue Engineering Research 2017;21(23):3718-3723
BACKGROUND:Photoelectric navigation-aided percutaneous pedicle screw placement has been developed extensively,but its accuracy,safety and effectiveness have not yet been confirmed by evidence-based medicine.OBJECTIVE:To compare the curative efficacy of photoelectric navigation-aided percutaneous pedicle screw placement and traditional open posterior pedicle screw fixation for thoracolumbar fractures.METHODS:Sixty patients with thoracolumbar fractures were equivalently randomized to treatment and control groups and then underwent photoelectric navigation-aided percutaneous pedicle screw placement and traditional open posterior pedicle screw fixation,respectively.The perioperative indexes,imaging indexes,function recovery and incidence of complications were compared between two groups.RESULTS AND CONCLUSION:(1) The Visual Analogue Scale scores,intraoperative blood loss,radiant times,and hospitalization time in the treatment group were significantly less than those in the control group (P < 0.05).(2) The operation time did not differ significantly between two groups (P > 0.05).(3) The postoperative sagittal Cobb angle,and percentage of anterior height in the vertebral body in the two groups were significantly improved compared with those before surgery (P < 0.05),but all above imaging indexes showed no significant differences between two groups (P > 0.05).The endplate-screw angle in the treatment group was significantly less than that in the control group (P < 0.05).(5) The excellent and good rate of placement in the treatment group was significantly higher than that in the control group (P < 0.05).(6) These results suggest that compared with the traditional open posterior pedicle screw fixation,the photoelectric navigation-aided percutaneous pedicle screw placement exhibits high placement accuracy,less radiant times,less trauma,less blood loss and rapid functional recovery.
9.Research progress of the natural small molecular products synergistically with antifungal agents to inhibit drug-resistant fungi.
Shan-Lun TAN ; Da-Zhi ZHANG ; Yuan-Ying JIANG
Acta Pharmaceutica Sinica 2014;49(8):1097-1104
The incidence of systemic fungal infections have increased dramatically, moreover, drug resistance including either primary (intrinsic) or secondary (acquired) resistance, becomes one of the main reasons accounting for the failure of treating invasive fungal infections in the past decades. Nowadays, clinically available antifungal drugs are limited and their combination in antifungal therapy was not effective. It is expected to be a new strategy to synergistically sensitize antifungal drugs against drug-resistant fungi by using new small molecules. Based on the study in our research group and the reported work of others, we reviewed the research of the natural products which have synergistic effect with the antifungal agents against drug-resistant fungi. This review focused on the resource, structure, pharmacological activity, and action mechanism of the compounds, as well as somewhat in common, and would provide theoretical base for seeking new drug against drug-resistance fungi.
Antifungal Agents
;
chemistry
;
pharmacology
;
Biological Products
;
chemistry
;
pharmacology
;
Drug Synergism
;
Fungi
;
drug effects
10.Analysis of the automatic brightness controlling for x-ray imaging systems.
Yong-li HUANG ; Tan QU ; Kai-lun LU ; Zheng-zi PAN
Chinese Journal of Medical Instrumentation 2002;26(6):402-406
In this paper, the question about automatic brightness control for x-ray imaging systems based on CCD camera is discussed, and the structure and principle of an auto brightness control loop are analyzed along with the working procedure of the x-ray imaging system. A kind of digital brightness controller about a typical device and the designing idea of the computer brightness intelligent control software is introduced.
Algorithms
;
Image Processing, Computer-Assisted
;
Radiation Protection
;
Radiographic Image Enhancement
;
instrumentation
;
Radiography
;
instrumentation
;
X-Ray Intensifying Screens