1.Relationship Between Plasma Levels of Soluble Receptor of Advanced Glycosylation End Products and Cardiac Function in Patients With Sepsis
Luanluan ZHANG ; Qiqun WANG ; De CHEN ; Rong ZHOU
Chinese Circulation Journal 2016;31(1):73-76
Objective: To explore the relationship between plasma levels of soluble receptor of advanced glycation end products (sRAGE), brain natriuretic peptide (BNP) and cardiac function in patients with sepsis.
Methods: A total of 83 sepsis patients treated in our hospital from 2014-01 to 2015-06 were studied. Plasma levels of sRAGE, BNP were examined at 24 h after admission and they were evaluated by APACHEII scores. According to BNP levels, the patients were divided into 2 groups:Normal cardiac function group, the patients with BNP<500 pg/ml, n=32 and Cardiac dysfunction group, the patients with BNP≥500 pg/ml, n=51. The cardiac function as stroke volume (SV), LVEF, minute volume, E/A were examined by echocardiography. The above indexes were analyzed and compared between 2 groups, the relationship between plasma levels of sRAGE and the occurrence of sepsis was assessed by Logistic regression analysis.
Results: Compared with Normal cardiac function group, the patients in Cardiac dysfunction group presented decreased SV, LVEF, minute volume and E/A;increased APACHEII scores and sRAGE, all P<0.01. Plasma levels of sRAGE in sepsis patients were positively related to BNP (r=0.90, P<0.05) and APACHEII scores (r=0.85, P<0.05). Logistic regression analysis indicated that plasma levels of sRAGE (OR=1.019, 95%CI 1.004-1.035, P<0.05) was independently related to cardiac function in patients with sepsis.
Conclusion: Plasma levels of sRAGE were independently related to cardiac function in patients with sepsis.
2.Study on cytotoxicity tests of medical devices based on IC50.
Chenghu LIU ; Shifu WU ; Li HOU ; Xin WANG ; Luanluan WANG ; Yanping SHI
Chinese Journal of Medical Instrumentation 2014;38(6):433-467
To discuss IC50 application in cytotoxicity tests of medical devices, we firstly investigated the vibrating condition and endpoint of MTT method specified in ISO 10993-5: 2009. Furthermore, we demonstrated the application of IC50 in the result evaluation of MTT method. The experimental results show that usage of IC50 in quantitative evaluation of MTT method is feasible.
Equipment and Supplies
;
adverse effects
;
standards
;
Inhibitory Concentration 50
;
Toxicity Tests
;
methods
3.Distribution of endogenous sulfur dioxide in severe acute pancreatitisrats
Qikun WANG ; Jianyun YUE ; Yan LU ; Luanluan ZHANG ; Xiaoyun GUO ; Chen CHAI ; Rong ZHOU
Chinese Journal of Emergency Medicine 2015;24(10):1111-1114
Objective The present study is to investigate the distribution of endogenous sulfur dioxide (SO2) in severe acute pancreatitis (SAP) rats.Methods Thirty-two SPF male Sprague-Dawley rats were randomized (random number) into sham operation group,SAP rat 3 h group (SAP 3 h),SAP rat 6 hgroup (SAP6h),SAP rat 12 hgroup (SAP 12 h),n=8 in each group.The SAPmodel rats were induced by retrograde cholangiopancreatic infusion of 5% sodium taurocholate.Rats were sacrified 3 h,6 h or 12 h after treatment.,then we collected pancrease,liver,lung,kidney and serum.The SO2 concentration in each tissue or serum was detected by enzyme-linked immune sorbentassay.Results The concentration of SO2 in tissues of pancreas (1.72 ± 0.14) μmol/g,liver (1.62 ± 0.11) μmol/g,lung (1.65 ± 0.11) μ.mol/g,kidney (1.12 ± 0.06) μmol/g or serum (16.80 ± 1.27) μmol/g in SAP 3 h rats was not significant compared with the sham operation group (P > 0.05 in each group).The SO2 content in the pancreas (1.89 ± 0.17) μmol/g,liver (1.92 ± 0.16) μmol/g,lung (1.91 ± 0.15) μmol/g,kidney (1.30 ± 0.10) μmol /g and serum (14.93 ± 1.00) μmol /g of SAP 6 h was significantly increased compared with sham operation group (P < 0.05 each group).The content SO2 in the pancreas (2.31 ± 0.23) μmol /g,liver (2.22 ± 0.15) μmol /g,lung (2.17 ± 0.07)μmol /g,kidney (1.55 ± 0.15) μmol /gand serum (18.88 ± 1.56) μmol /g of SAP rats reached the peak 12Hafter treatment and was significantly higher compared with the sham operation group (P < 0.05).Conclusions The increase of SO2 concentration in SAP might be,at least in our present opinion,involved into the pathogenesis of SAP rats.
4.Birth weight predicts physical indicators in adulthood: a large population-based study in Chinese twins
Chunxiao LIAO ; Wenjing GAO ; Luanluan SUN ; Ying GAO ; Weihua CAO ; Jun LYU ; Canqing YU ; Shengfeng WANG ; Zengchang PANG ; Liming CONG ; Zhong DONG ; Fan WU ; Hua WANG ; Xianping WU ; Guohong JIANG ; Xiaojie WANG ; Binyou WANG ; Liming LI
Chinese Journal of Epidemiology 2020;41(3):310-314
Objective:To quantitate the association between birth weight and phenotypes of physical indicators in adulthood, i.e. BMI and waist circumference (WC) and to what degree genetic or environmental factors affect birth weight-obesity association.Methods:A total of 6 623 gender matched twin pairs aged 25 to 79 years were recruited through the Chinese National Twin Registry. The twins reported their own birth weight, current height and weight, and WC using a self-administered questionnaire. BMI was calculated according to the self-reports of body height and weight. Within twin-pair design was used to quantitate the association between birth weight and phenotypes related to obesity while bivariate structural equation models were used to decompose the phenotype correlation.Results:After adjusted for multiple factors, twin-pair analyses within monozygotic (MZ) showed that, on average, a 1.0 kg increase in birth weight corresponded to an increase of 0.33 kg/m 2 in BMI and 0.95 cm in WC in adulthood ( P<0.001). Bivariate structural equation models showed significant positive unique environmental correlation between birth weight and the two obesity-related phenotypes. Conclusion:The study supported the role of twin-specific supply line factors on relationship between birth weight and physical indicators in adulthood.
5.Investigation and Analysis of Off-label Use of Estradiol Preparation in ART Patients of a Hospital
Bing SITU ; Luanluan CHEN ; Jianqiao LIU ; Ying WANG ; Weiliang ZHANG ; Xiangping TAN ; Zhengrong MEI
China Pharmacy 2019;30(2):264-268
OBJECTIVE: To provide reference for rational use of estradiol (E2) preparation in clinic. METHODS: The medical records of outpatients receiving assisted reproductive technology (ART) and E2 preparation [Estradiol valerate tablets (EV), Complex packing estradiol tablets/estradiol and dydrogesterone tablets (EP), Estradiol gel (EG)] were collected from the reproductive medicine center of a hospital during Jan. 2016-Mar. 2017. Taking drug instruction as standard, the rationality of medical records was evaluated from aspects of indication, route of administration, contraindication, usage and dosage, treatment course, etc. At the same time, these patients were followed up by telephone or outpatient service, and their pregnancy outcomes and ADR were summarized. RESULTS: A total of 12 646 prescriptions were collected, and 7 222, 3 912, 181 and 1 331 prescriptions used EV, EP, EG and EV+EP, respectively. The types of off-label use included over-indication, over-route and over-contraindication, and the rates of off-label use rates were 100%, 11.73% and 43.60%, respectively. A total of 5 868 ART patients were involved; 439 patients received fresh embryo transplantation, and 5 429 patients received frozen-thawed embryo transplantation, involving 720 and 11 926 prescriptions, respectively. The rates of off-label use of above E2 preparations were 100% (except for fresh embryo transplantation patients using EG). As of Feb. 2018, the infant-holding rates of ART patients using EV, EP, EG and EV+EP were 85.29%, 85.37%, 86.36% and 85.45%, respectively. No relevant ADR and neonatal birth defect was found. CONCLUSIONS: The phenomenon of off-label use of E2 preparations is widespread in the reproductive medicine center of the hospital. Although there is no indication of related safety risks, evidence-based evaluation should be carried out by enlarging the sample size in clinical practice, and careful use.