1.Preliminary study on the diagnostic efficacy of contrast-enhanced ultrasound in breast solid ductal papilloma
Lizhu HOU ; Yan ZHENG ; Ying SONG ; Mengqi ZHOU ; Lin ZHU ; Dan ZHAO ; Wei WANG ; Fenglin DONG
Chinese Journal of Ultrasonography 2024;33(5):378-384
Objective:To evaluate the value of contrast-enhanced ultrasound (CEUS) in the diagnosis of solid intraductal papilloma (sIDP) of breast by comparing with fibronenoma of breast (FA).Methods:The CEUS data of 62 cases of sIDP patients and 94 cases of FA patients that confirmed by pathology in the First Affiliated Hospital of Soochow University from October 2016 to January 2021 were retrospectively analyzed. The patients were divided into sIDP group and FA group according to the pathological results. The enhancement speed, enhancement degree, enhancement uniformity, whether the edge after enhancement was polished, whether the enhancement range was enlarged, whether there was a ring unenhanced area in the inner edge of the lesion and whether the inner edge of the unenhanced area was polished were observed in the two groups. SonoLiver software was used to perform offline analysis of the dynamic process of CEUS in the two groups respectively, the enhancement sequence diagram of the lesions was obtained. The pathological result was taken as the gold standard, univariate analysis was applied, and the parameters with statistical significance between the two groups were included in multivariate Logistic regression analysis to establish a differential diagnosis model. The diagnostic efficiency of sIDP was analyzed by ROC curve and diagnostic model.Results:Compared with the FA group, CEUS in the sIDP group mostly showed fast forward, high enhancement, and the enhancement sequence was mostly centrifugal. After CEUS, the lesion edges in the sIDP group were mostly accompanied by unenhanced areas and the inner edges of the unenhanced areas were not intact, and the differences between the two groups were statistically significant (all P<0.05). Binary Logistic regression showed that age, enhancement degree and enhancement order were independent risk factors for sIDP diagnosis. The ROC curve showed that the area under the ROC curve of age, enhancement degree and enhancement sequence combined for the diagnosis of sIDP was 0.874 (95% CI=0.812-0.922), the accuracy was 76.9%, the sensitivity was 67.7%, the specificity was 83.0%, the positive predictive value was 72.4%, and the negative predictive value was 79.6%. Conclusions:There are significant differences in age, enhancement degree and enhancement sequence between sIDP and FA patients. The three-parameter combination can improve the diagnostic efficiency of sIDP.
2. Clinical application of contrast-enhanced ultrasound combined with modified labeled method in locating sentinel lymph nodes of breast cancer
Yan ZHENG ; Jie SUN ; Mengshang HU ; Lizhu HOU ; Jianxia LIU ; Fenglin DONG
Chinese Journal of Ultrasonography 2019;28(12):1061-1065
Objective:
To explore the clinical value of contrast-enhanced ultrasound combined with modified labeled method in labeling sentinel lymph nodes of breast cancer in comparison with nano-carbon stained method.
Methods:
Eighty female breast cancer patients who underwent surgery in the First Affiliated Hospital of Soochow University between July 2017 and April 2019 were enrolled. Sentinel lymph nodes in all patients were labeled by contrast-enhanced ultrasound combined with modified labeled method and nano-carbon stained method, respectively. The consistency of first lymph node labeled by the two methods was judged, the number of SLNs labeled by two methods was counted, and the pathology of the labeled SLN was compared with that after axillary dissection.
Results:
The two methods have good consistency in locating sentinel lymph nodes of breast cancer(Kappa=0.749,
3.Principles for the rational use of national key monitoring drugs (the second batch)
Yuan BIAN ; Min CHEN ; Shan DU ; Wenyuan LI ; Lizhu HAN ; Qinan YIN ; Xiaojiao CUI ; Xuefei HUANG ; Zhujun CHEN ; Yang LEI ; Yingying HOU ; Xiaoqing YI ; Yueyuan WANG ; Xi ZHENG ; Xinxia LIU ; Ziyan LYU ; Yue WU ; Lian LI ; Xingyue ZHENG ; Liuyun WU ; Junfeng YAN ; Rongsheng TONG
China Pharmacy 2023;34(20):2433-2453
In order to strengthen the supervision of the use of drugs in hospitals,the Sichuan Academy of Medical Sciences· Sichuan Provincial People’s Hospital took the lead in compiling the Principles for the Rational Use of National Key Monitoring Drugs (the Second Batch) with a number of experts from multiple medical units in accordance with the Second Batch of National Key Monitoring Rational Drug Use List (hereinafter referred to as “the List”) issued by the National Health Commission. According to the method of the WHO Guidelines Development Manual, the writing team used the Delphi method to unify expert opinions by reading and summarizing the domestic and foreign literature evidence of related drugs, and applied the evaluation, formulation and evaluation method of recommendation grading (GRADE) to evaluate the quality of evidence formed, focusing on more than 30 drugs in the List about the evaluation of off-label indications of drugs, key points of rational drug use and key points of pharmaceutical monitoring. It aims to promote the scientific standardization and effective management of clinical medication, further improve the quality of medical services, reduce the risk of adverse drug reactions and drug abuse, promote rational drug use, and improve public health.