1.Ultrasound-guided percutaneous ethanol injection in the treatment of hepatocellular carcinoma combined with portal vein tumor thrombosis
Xiujuan ZHANG ; Liwu LIN ; Ensheng XUE ; Zhikui CHEN ; Liyun YU
Chinese Journal of Interventional Imaging and Therapy 2011;08(5):367-370
ObjectiveTo assess the clinical value of ultrasound-guided percutaneous ethanol injection (PEI) in the treatment of hepatocellular carcinoma (HCC) combined with portal vein tumor thrombosis (PVTT).MethodsNinety HCC patients with different type PVTT underwent ultrasound-guided PEI once or twice a week.The follow-up lasted 12 to 60 months,and the 1-,2-,3-,4- and 5-year survival rates were calculated.ResultsThe median survival time of HCC combined with PVTT patients treated with PEI was 12 months,and the 1-,2-,3-,4- and 5-year survival rates was 52.22%,23.33%,15.56%,12.22% and 10.00%,respectively.The survival rate correlated significantly to the type of PVTT.The lower the type of PVTT was,the longer the patients lived.ConclusionUltrasound-guided PEI is a safe and effective method for the treatment of HCC combined with PVTT,and can prolong the survival time of HCC patients with low type PVTT.
2.Injectable and biodegradable thermosensitive PLGA-PEG-PLGA copolymer-based hyd rogels for a controlled in vitro drug delivery
Zhikui CHEN ; Liwu LIN ; Yahfang LIN ; Ensheng XUE ; Liyun YU
Chinese Journal of Tissue Engineering Research 2008;12(49):9792-9796
BACKGROUND:Ricin possesses strong cytotoxicity but lacks of specificity.Severe adverse reactions can be caused if ricin is systemically administered.Interstitial chemotherapy with ricin coated by a sustained-release carrier can enhance local therapeutic effects of tumor,avoiding systemic-toxic occurrence.OBJECTIVE:To prepare injectable and biodegradable thermosensitive poly(D,L-lactide-co-glycolide)(PLGA)-polyethylene glycol(PEG)-PLGA copolymer-based hydrogels and to observe the in vitro drug delivery of the PLGA-PEO-PLGA copolymer hydrogel as a sustained-release carrier of ricin.DESIGN,TIME AND SETTING:A controlled observation was performed at the Center for Medical Bioengineering.Fujian Medical University between August and December 2007.MATERlALS:Ricin with a purity of 95%was purified by Fuiian Institute of Ultrasonic Medicine.DL-lactide and L-glycolide were provided by Glycolide Lactide Co.,Ltd..China.METHODS:PLGA-PEG-PLGA-copolymer was synthesized by ring-opening polymerization.MAIN OUTCOME MEASURES:Phase transition temperature was determined by test tube turnover.relativemolecular mass by high-performance gel permeation chromatography,the proportion of block copolymer by nuclear magnetic resonance spectrometry.the in vitro drug delivery of ricin coated by PLGA-PEG-PLGA copolymcr hydrogelby enzyme linked immunosorbent assay.the structural integrity of released ricin by high-performance liquid chromatography,the cytotoxicity of released ricin by methyl thiazolyl tetrazolium assay.RESULTS:The synthesized copolymer PLGA-PEG-PLGA exhibited reverse.thermosensitivity.The phase transition temperature of the copolymer was 26℃at 230 g/L.The weight-average molecular weight and number-average molecular weight of this copolymer was 8 027 and 6 643,respectively,and the multiple-dispersion toefficient was 1.17.The block ratio for PEG and PLGA was 3:2.Drug-loaded PLGA-PEG-PLGA hydrogel could release ricin in vitro for a total of 18 successive days and simultaneously well maintain cytotoxicity and the structural stability of ricin.CONCLUSION:PLGA-PEG-PLGA copolymer is an ideal carrier for sustained delivery of ricin
3.Study of influential factors in evaluating tissue stiffness by virtual touch tissue quantification
Liyun XUE ; Jiexian WEN ; Qing LU ; Cuiju YAN ; Beijian HUANG ; Wenping WANG
Chinese Journal of Ultrasonography 2012;21(6):526-528
ObjectiveTo investigate the influence of different depths and mediums on tissue stiffness measurement by virtual touch tissue quantification technology.Methods Four kinds of in vitro porcine tissue were recruited,three (fat,muscle and liver) were assigned as medium group and three (kidney,liver and muscle) as sample group.The shear wave velocity (Vs) of the samples was measured under different mediums and at different depths (2 cm,3 cm,4 cm and 5 cm),respectively.ResultsAccording to the depth of measurement,two groups of Vs were defined with one group at the depth of 2 cm and 3 cm while the other at 4 cm and 5 cm.The difference of Vs between the two groups was of statistical significance and with the increase of the depth Vs values decreased.Even at the same depth,the differences of Vs under different mediums were statistically significant.ConclusionsDepths and mediums have great influence on evaluating elasticity measurements by virtual touch tissue quantification technology.
4.Family cognitive training for patients with vascular cognitive impairment
Junqing ZHAO ; Xiaohong QIU ; Yuan XUE ; Lifang CHE ; Liyun GUO ; Yufen WANG
Chinese Journal of Physical Medicine and Rehabilitation 2014;36(6):413-415
Objective To observe the effects of family cognitive training on patients with vascular cognitive impairment but without dementia.Methods Sixty patients with non-dementia type vascular cognitive impairment were divided at random into a group which received family cognitive training (30 cases) and a control group (30 cases).The 2 groups all took routine drugs and exercise.The family cognitive training group received cognitive training additionally.Before treatment and after 1 and 6 months of treatment,all of the patients of both groups were assessed using the mini-mental state examination (MMSE),the Montreal cognitive assessment (MoCA) and the modified Barthel index (MBI).Results After 1 month of treatment there was no significant difference between the 2 groups in any of the assessments.After6 months the scores on each item of the MMSE,MoCA and MBI had improved significantly more in the family cognitive training group than in the control group.Conclusion Family cognitive training is effective in treating non-dementia type vascular cognitive impairment.It can delay disease progression and improve cognitive function and ability in the activities of daily living.
5.Comparative analysis on ultrasonic and mammographic characteristics of breast chronic inlfammation
Min, LIN ; Weili, WEI ; Zhikui, CHEN ; Liwu, LIN ; Ensheng, XUE ; Yimi, HE ; Liyun, YU
Chinese Journal of Medical Ultrasound (Electronic Edition) 2014;(3):50-53
Objective To compare the ultrasonic and mammographic appearances of breast chronic inflammation (BCI). Methods The ultrasonic and mammographic features of 20 pathologically conifrmed BCI cases were analyzed retrospectively. All cases were of single lesion. Fisher deifnite probability method was used to compare the differences between ultrasonic and mammographic appearances as well as the diagnostic coincidence rate. Results Under ultrasonography, the mean longitudinal diameter/transverse diameter (L/T) ratio of 20 lessions was calcultated as 0.47±0.15, 17 lesions were of irregular shape, unclear boundary and inhomogeneous hypoecho, 13 lesions were of posterior echo enhancement, the blood lfow of 10 lesions belonged to 0-Ⅰ, and the other 10 belonged toⅡ-Ⅲ. The lesion shape, boundary and homogeneity detected by mammography were coincident to those by ultrasonography (P=1.00, 1.00, 0.61, respectively). In 5 lesions, dotted high-echoes were detected by ultrasonography, however no calciifcation was found by mammography. Meanwhile, 1 lesion with sporadic calciifcation detected by mammography was missed by ultrasonography. Ultrasonography detected 5 cases with axillary lymphadenopathy, in which only 1 case was found by mammography. The diagnostic coincidence rate of ultrasonography was 40%(8/20), which was obviously higher than 6% (1/16) by mammography (P=0.03). Conclusion BCI possesses certain ultrasonographic characteristics, and ultrasonography combined with mammography will be helpful for the differential diagnosis of malignant and benign diseases.
6.Value of contrast-enhanced ultrasound in diagnosis of renal epithelioid angiomyolipoma
Cuixian LI ; Beijian HUANG ; Qing LU ; Liyun XUE ; Lixia YAN ; Jiexian WEN ; Wenping WANG
Chinese Journal of Ultrasonography 2014;23(9):786-790
Objective To investigate the value of contrast-enhanced ultrasound (CEUS) in diagnosis of renal epithelioid angiomyolipoma (eAML).Methods The CEUS features of 18 patients with 18 histopathologically proved renal eAMLs were retrospective analyzed using both of qualitative and quantitative approachs.Tumor conventional ultrasound and CEUS features were observed.The Sonoliver software was applied to perform quantitative analysis,which provided five parameters,including the maximum intensity (IMAX),rise time (RT),time to peak (TTP),mean transit time (mTT) and area under the curve (AUC).Results All of 18 lesions were pathological proved as eAML,among them,heterocyst was observed in 7 lesions,1 lesion had dissemination inter-kidney and vessel invasion,necrosis or cystic degeneration was found in 3 eAMLs.On conventional ultrasound,eAML showed hypoecho,isoecho and hyperecho were 14(77.8%),3(16.7%) and 1 (5.6%) respectively.Blood flow could be detected in 16 (88.9%) lesions.On CEUS,the characters of slow-in,synchronous-in,slow centripetal enhancement and entire enhancement were observed in 10 (55.6%),8 (44.4%),8 (44.4%) and 12 (55.6%) lesions,respectively.Most of eAMLs showed homogeneous enhancement (15/18,83.3%) and hyper-or iso-enhancement (16/18,88.8 %) at peak time.The characters of fast-out,synchronous-out and slow out were observed in 8 (44.4%),2 (11.2%) and 8 (44.4%) cases,respectively.Pseudocapsule was detected in 5 (27.8%) lesions.The parameters of RT,TP and AUC for eAMLs were higher than that for renal cortex (P < 0.05),while the parameters of IMAX and mTT had no significant statistical difference between eAMLs and renal cortex(P >0.05).Conclusions Qualitative and quantitative analysis of CEUS reflect the blood perfusion of eAMLs in different aspect,which offer some useful informations for the diagnosis of eAMLs.
7.Value of ultrasonography in diagnosis and differential diagnosis of breast sclerosing adenosis
Ying HOU ; Liwu LIN ; Ensheng XUE ; Zhikui CHEN ; Liyan HUANG ; Liyun YU ; Yimi HE
Chinese Journal of Ultrasonography 2014;23(10):889-892
Objective To investigate the value of color Doppler ultrasonography in diagnosis and differential diagnosis of breast sclerosing adenosis (SA).Methods Preoperative sonography in 32 SA,99 invasive ductal carcinoma(IDC),51 ductal carcinoma in situ(DCIS) and 64 fibroadenoma(FA) confirmed by pathology were retrospectively analyzed.Results The average age of SA group was younger than IDC and DCIS groups',but older than FA group's (P <0.05).The focal maximum diameter of SA group was the smallest among all(P <0.05).All the SA sonograms showed solid hypoechoic lesions,with spiculate margin was less than IDC group and larger than DCIS and FA groups (P <0.05).Similar ultrasonic characteristics,such as irregular shape,unclear border,acoustic halos were seen in SA and DCIS groups (P >0.05),while IDC group showed the highest rate and FA group had the least(P <0.05).SA masses' uneven internal echo,calcification,posterior acoustic attenuation was higher than FA group(P <0.05),but less than IDC and DCIS groups(P >0.05).Meanwhile,A/T ratios(≥0.7) were higher than DCIS and FA groups,but less than IDC group(P >0.05).In addition,SA group had a similar detection rate of the internal blood flow with FA group(P >0.05),but less than the IDC and DCIS groups(P <0.05).Conelusions Ultrasonography has a significant clinical value in diagnosis and differential breast sclerosing adenosis.
8.Application value of color Doppler ultrasound in metaplastic breast carcinoma
Xiaoshuang CHEN ; Xiujuan ZHANG ; Liwu LIN ; Ensheng XUE ; Liyun YU ; Yimi HE
Chinese Journal of Ultrasonography 2016;25(3):223-227
Objective To investigate the value of color Doppler ultrasonography in metaplastic breast carcinoma(MBC).Methods The ultrasonic characteristics of 23 MBC and 1 1 8 invasive ductal carcinoma (IDC) confirmed by pathology were analyzed retrospectively.And the ultrasound characteristics of different types of MBC was analyzed according to pathology.Results Mean maximum diameter of(3.73±1 .74)cm in MBC was larger than that in IDC[(2.57 ± 1 .19)cm,P = 0.005].Most MBC lesions showed larger diameter(>3 cm),clear border(56.5%),irregular shape(65.2%),lack of hyperechoic halos(65.2%), posterior enhancement(60.9%),no calcification(60.9%) and grade 2 - 3 of blood flow (56.5%).The detection rate of unclear border,unsmooth edge and hyperechoic halos of MBC was lower than those of IDC (P <0.05).But MBC had a higher detection rate in the masses with larger than 3 cm in diameter and posterior enhancement than IDC.Five (45.5%) lesions of 1 1 squamous cell carcinoma showed cystic constituent.The mean maximum diameter of 5 MBC with mecenchymal tissue lesions was larger than spindle cell carcinoma,but smaller than squamous cell carcinoma.And 4 lesions of the 5 MBC with mecenchymal tissue showed calcification,which occupied the highest proportion among different pathological types of MBC. The ultrasonic coincidence rate for MBC was 86.96%.Conclusions The ultrasonic appearances of MBC have a certain characteristics,and different pathological types of MBC also have corresponding characteristics.It shows important value of ultrasonography in preoperative diagnosis for MBC.
9.Ultrasonic appearances of intrascrotal adenomatoid tumor
Wenjin LIN ; Ensheng XUE ; Liyun YU ; Shun CHEN ; Rongxi LIANG ; Qingfu QIAN
Chinese Journal of Ultrasonography 2015;24(11):992-995
Objective To explore the sonographic features of intrascrotal adenomatoid tumor.Methods The sonographic features of 21 cases with intrascrotal adenomatoid tumor confirmed by surgery and pathology were retrospectively analyzed.Results Twenty-one cases with intrascrotal adenomatoid tumor could be typed into 3 ultrasonic patterns:(1) The homogeneous echo type:15 cases,their ultrasonic features were homogeneous echo,including 5 cases with low echo,8 case with equal echo,and 2 case with high echo;5 cases with testicular albuginea adenomatous tumors were also homogeneous echo,2 cases of equal echo,2 cases of low echo and 1 case of high echo that was posterior echo attenuation slightly.(2) The edge halo type:4 cases,they showed the epididymis or testis sheath round or oval nodules,of which the middle was low echo and the edge is high echo halo ring.(3) The mixed echo type:2 cases,they showed cystic mixed echo of epididymis nodules,1 case with irregular cystic areas and poor sound transmission,while the other one with good sound transmission cystic areas and a small papillae on the wall.Conclusions Sonography is a valuable method for diagnosis of intrascrotal adenomatoid tumor.The edge halo type has sonographic features.
10.Experimental study on contrast-enhanced ultrasound to evaluate testicular microvascular injury
Wenjin LIN ; Ensheng XUE ; Liyun YU ; Yusheng LI ; Shun CHEN ; Rongxi LIANG ; Wenrong LIN ; Liping HUANG
Chinese Journal of Ultrasonography 2015;(6):535-540
Objective To explore the way of contrast-enhanced ultrasound(CEUS)and quantitative analysis technology to assess testicular microvascular ischemia-reperfusion inj ury.Methods Twenty-four healthy adult rabbits were randomly divided into the control group and the microvascular mild,moderate, serve ischemic inj ury group (group Ⅰ,including group Ⅰ1 ,Ⅰ2 ,Ⅰ3 ).The spermatic cord of the control group were threaded but not ligated.The group Ⅰ1 ,Ⅰ2 ,Ⅰ3 were reperfused 2 h after 2 h,4 h,6 h complete testicular ischemia respectively.The ultrasound contrast angiographic parameters of each group were analyzed by the quantitative analysis techniques,including peak intensity(PI),time to peak(TP),slope,mean transmit time(MTT),DT/2 and area.The levels of plasma vWF,NO and ET-1 were tested after the CEUS. The pathological changes of the ipsilateral testicular were observed by the HE and immunohistochemical staining.Statistical analysis was performed by SPSS 13.0 software.Results Preoperativeiy,each parameter of the experimental group and the control group showed no statistical significance (P > 0.05 ). Postoperatively,the PI,slope,area of the group Ⅰ1 increased significantly,while the TP,MTT were prolonged(P <0.05).Contrast time-intensity curve was significantly higher peak and retrusion.The groupⅠ2's PI,slope,area increased further,DT/2 was significantly prolonged,but TP significantly reduced (P <0.05).The contrast curve significantly increased,forward and decreased slowly.The contrast curves of the group Ⅰ3 was approximate a straight line.The vWF,NO,ET-1 levels of each experimental group were significantly higher than those in control group (P <0.05),among them,the levels of group Ⅰ2 were the highest (P <0.05 ).With the aggravation of ischemia,the testicular capillaries expansion,erythrocyte sedimentation,leakage,infiltration of inflammatory cells,MMP-9 expression in vascular basement membrane gradually increased.Conclusions The CEUS and quantitative analysis techniques can effectively evaluate testicular microvascular inj ury.