1.Stasis Cirrhosis:Imaging Features and Pathological Basis
Guangwen CHEN ; Bin SONG ; Litao CHEN ; Xueqin ZHANG
Journal of Practical Radiology 2010;26(1):31-35
Objective To investigate mut-slice spiral CT(MSCT) and MRI features and correlated pathological basis of stasis cirrhosis.Methods MSCT and MRI findings of 35 patients with stasis cirrhosis (study group) and 35 patients with posthepatitic cirrhosis (control group) were studied retrospectively. Volume index of liver and spleen, caliber of hepatic vein and the number of regenerative nodules exceeded 5mm in diameter were measured.The contrast-enhanced patterns of liver parenchyma, contrast medium reflux, ascites, the number of varices and correlated abnormalities were reviewed.Results The volume indexes of liver and spleen, calibers of hepatic vein were (4434.95±1283.08) cm~3,(621.92±400.33) cm~3 and (3.61±0.81) cm in the study group,(2569.73±853.06) cm~3,(1275.61±727.51) cm~3 and (1.92±0.46) cm in the control group,respectively.The number of the patients showed waves of borderline, inhomogeneous pattern of parenchymal contrast enhancement, regenerative nodules exceeded 5mm in diameter, contrast medium reflux, varices and ascites were 5, 29, 17, 20, 16 and 6 cases in the study group,29,0,5,0,35 and 26 cases in the control group,respectively,there were statistic differences between the study group and control group(P<0.05).Conclusion MSCT and MRI play a invaluable role in the diagnosis and differential diagnosis and etiological diagnosis of stasis cirrhosis.
2.The value of three-dimensional ultrasound in evaluating carotid artery plaquevolume and predicting risk events in coronary heart disease patients
Yan SONG ; Ying DANG ; Jing SHANG ; Bo LIU ; Litao RUAN
Journal of Xi'an Jiaotong University(Medical Sciences) 2017;38(5):706-709
Objective To assess whether the plaque volume of carotid artery evaluated by three-dimensional ultrasound can predict the risk of cardiovascular events earlier in patients with coronary heart disease, in comparison with plaque thickness.Methods A total of 99 patients were enrolled, including 66 patients with asymptomatic carotid plaque and 33 patients with coronary heart disease (CHD) and carotid plaque.Three-dimensional ultrasound was performed in all the patients.Coronary angiography was performed in all the patients in CHD group.Coronary artery Gensini score was calculated.Plaque thickness, plaque area and plaque volume were compared between the two groups.We analyzed the relationship of plaque volume with Gensini score and other cardiovascular risk factors.Results Plaque volume was significantly higher in CHD group [(1312.38±513.70)mm3] than in asymptomatic group [(947.54±321.41)mm3] (P=0.023).However, plaque thickness and plaque area were not significantly different between the two groups (P>0.05).Plaque volume was positively correlated with Gensini score (r=0.519, P=0.002), homocysteine (r=0.569, P=0.002), and cardiovascular risk factors such as diabetes, blood glucose and glycosylated hemoglobin.There was a negative correlation between plaque volume and high-density lipoprotein (HDL), a factor protecting against cardiovascular events (r=-0.387, P=0.038).Conclusion Compared with plaque thickness, the volume of carotid plaques assessed by three-dimensional imaging technique may be a better predictor of the risk of cardiovascular events in patients with coronary heart disease.
3.Diagnostic Value of MSCT and MRI for Stasis Cirrhosis
Guangwen CHEN ; Bin SONG ; Litao CHEN ; Liming ZHAO ; Ningjing YANG
Chinese Journal of Bases and Clinics in General Surgery 2003;0(06):-
Objective To investigate multi-slice spiral CT (MSCT) and MRI features of stasis cirrhosis and the diagnostic value of MSCT and MRI. Methods MSCT and MRI findings of 35 patients with stasis cirrhosis were studied. The size of liver and spleen, the diameter of hepatic vein (HV), enhancement pattern of liver parenchyma, contrast medium reflux in inferior vena cava (IVC) and (or) HV, ascites, number of varices and correlated abnormalities were reviewed. Results The volume index of liver and spleen of 35 patients was 4 434.95 cm3 and 621.92 cm3 respectively. The mean diameter of HV of 27 patients (77.1%) was 3.61 cm and HV of other 8 patients (22.9%) were too small to show. Number of patients showed waves of borderline, inhomogeneous pattern of parenchymal contrast enhancement, contrast medium reflux in IVC and (or) HV, varices and ascites was 5 (14.3%), 29 (82.9%), 20 (57.1%), 16 (45.7%), and 6 (17.1%), respectively. Correlated abnormalities included cardiac enlargement 4 cases (11.4%), pericardium thickening 11 cases (31.4%), and pericardial effusion 2 cases (5.7%). Conclusions Stasis cirrhosis mainly demonstrate liver enlargement, inhomogeneous pattern of parenchymal contrast enhancement, contrast medium reflux in IVC and (or) HV, and slight portal hypertension. MSCT and MRI play invaluable roles in diagnosis, differential diagnosis and etiological diagnosis of stasis cirrhosis.
4.Diagnostic Value of 64 Slice Spiral Computed Tomography for Budd-Chiari Syndrome
Guangwen CHEN ; Litao CHEN ; Bin SONG ; Fang YUAN ; Xie ZHANG
Chinese Journal of Bases and Clinics in General Surgery 2008;0(09):-
Objective To investigate the imaging features of Budd-Chiari syndrome(BCS) on 64 slice spiral computed tomography(64SCT) and the diagnostic value of 64SCT for BCS.Methods Twenty-nine patients diagnosed as BCS by 64SCT were retrospectively included into this study and all the patients were researched by digital substraction angiography(DSA).Two abdominal radiologists analyzed the CT imaging features of BCS,paying attention to the vascular lesion,the morphology abnormality of the liver and the degree of portal hypertension,with review of DSA findings.Results ①The accuracy of 64SCT for BCS was 93.1%(27/29),and there were 2 false positive cases and no false negative case.The accuracy of 64SCT for those patients with thrombosis of inferior vena cava(IVC) and(or) hepatic vein(HV) was high as compared to those with stenosis of IVC and(or) HV.②The morphology abnormality of the liver included hepatomegaly(24 cases),low attenuation(27 cases) and inhomogeneous pattern of parenchymal contrast enhancement(5 patients in arterial phase and 19 patients in portal vein phase).③The images of all the patients showed the features of portal hypertension.Conclusion The accuracy of 64SCT for BCS is satisfactory and the false negative is seldom.The 64SCT could accurately display the morphology abnormality of the liver and the compensatory circulation in BCS patients.For those patients with stenosis of IVC and(or) HV,however,the diagnostic power of 64SCT is limited.
5.Value of Multi-Detector Row Spiral CT and 3-Dimensional Reconstruction Technique for Intussusception
Guangwen CHEN ; Bin SONG ; Litao CHEN ; Bi WU ; Zhenlin LI
Chinese Journal of Bases and Clinics in General Surgery 2008;0(10):-
0.05).For following indexes: whether or not having intussusception,the location of intussusception,finding reason caused intussusception,the confidence index of the doctor between original image add MPR image group and original image group had significant difference(5.00 vs.4.24,4.76 vs.4.29,4.29 vs.3.71),and the confidence index of the doctor of original image add MPR image group exceeded that of original image group(P
6.Structure, Immunogenicity and Clinical Value of Chlamydiaphage Capsid Protein 3.
Weifeng YAO ; Yiju LI ; Jing YUAN ; Lei WANG ; Qunyan LI ; Mengmeng SONG ; Guiling LU ; Litao ZHANG
Chinese Journal of Virology 2015;31(4):420-424
We wished to assess the role of chlamydia micro virus capsid protein Vp3 in recombinant molecules, chart its molecular evolution, screen the wild-type strain, and reveal its value in clinical research. Using a protein BLAST multiple-alignment program, we compared various strains of Chlamydia micro virus capsid protein Vp3 sequences. Using a "distance tree" of those results, we created a phylogenetic tree. We applied the Karplus-Schulz method of flexible-region analyses for highly conserved alignments of amino-acid sequences. Gamier-Robson and Chou-Fasman methods were employed to analyze two-level structures of sequences. The Emini method was used for analyses of the accessibility of surface epitopes. Studies of hydrophilic proteins were undertaken using Kyte-Doolittle and Hopp-Woods methods. Analyses of antigen epitopes helped to reveal the antigen index using the Jameson-Wolf method. All sequences in the six strains of chlamydia micro virus capsid protein Vp3 were highly conserved, with the main differences being between Vp3 protein in Chp1 and the other five strains of the micro virus. The viral strain of Vp3 protein was based mainly on micro-alpha helix structures, and multiple epitopes were noted in highly conserved regions. Vp3 protein was highly conserved structurally, and was an important protein of the chlamydiaphage capsid. Vp3 protein has a complicated molecular structure, highly conserved regions with strong immunogenicity, and has considerable research value.
Amino Acid Sequence
;
Capsid Proteins
;
chemistry
;
genetics
;
immunology
;
Chlamydia
;
genetics
;
immunology
;
Conserved Sequence
;
Epitope Mapping
;
Evolution, Molecular
;
Molecular Sequence Data
;
Recombination, Genetic
7.Improvement of instrument for preparation of medical patch material
Lixia YANG ; Yunze WANG ; Guofeng YANG ; Meina XIE ; Yili LI ; Jing LI ; Litao FAN ; Lingjie SONG
Chinese Medical Equipment Journal 2017;38(5):25-28
Objective To modify the existing preparation instrument for medical patch material to realize its scale and automatic production.Methods The instrument had its shaking table improved and a cylindrical processing system added with comprehensive analysis on raw materials and kinds of process flows.A spreading and fixation mechanism for animal materials was placed in the cylindrical processing system,which had the holes for liquid inlet and outlet respectively on its top and bottom.The cylindrical processing system was fixed to the base of the shaking table.Results The instrument enhanced preparation efficiency significantly,and had the raw material utilization rate increased by 20%,product qualification rate raised by 35%,preparation cycle reduced by 33% and total cost saved by 40%.Conclusion The instrument behaves well in adaptability to multi animals,preparation process,inter-assay difference,raw material utilization rate,product qualification rate and cost reduction,which is of great significance to promote the clinical application of medical biological patch.
8.The correlation between intraplaque neovascularization detected by contrast-enhanced ultrasound with the level of serum homocysteine
Xiaoni CHANG ; Jun FENG ; Litao RUAN ; Jing SHANG ; Yanqiu YANG ; Jian SUN ; Yan SONG
Chinese Journal of Ultrasonography 2014;23(3):206-210
Objective To explore the relationship between the degree of intraplaque neovascularization in carotid artery and the level of serum homocysteine.Methods Contrast-enhanced ultrasound were performed on 72 carotid atherosclerotic plaques of 48 patients.Contrast-enhancement within the plaque was categorizde as grade 1 to grade 3.The level of serum homocysteine were detected in the fasting state during the same period.Results According to the degree of contrast enhancement(grade 1 to 3),patients were divided into 3 groups.The more new vessels in plaque,the higher the level of homocysteine.The levels of homocysteine in three groups increased in turn.There were distinct differences among the three groups(F =18.49,P <0.05),and there was significant difference between every two groups (P <0.05).The linear correlation analysis showed that the level of homocysteine was positively correlated with the degree of carotid plaque enhancement (r =0.66,P < 0.01).Conclusions Contrastenhanced ultrasonography could semi-quantitate new vessles in plaque.There was positive correlation between the degree of intraplaque neovascularization with the level of serum homocysteine.Combine with the level of serum homocysteine based on intraplaque neovascularization detected by contrast-enhanced ultrasound,the plaque stability could be more accurately evaluated.
9.Application of diffusion weighted imaging with background suppression in evaluating the injury of lower limb nerves in patients with Guillain-Barre syndrome
Jinfeng CAO ; Shanshan WANG ; Bing HE ; Tao GONG ; Xin LUO ; Xinru SUN ; Hao LIU ; Litao SONG ; Guangbin WANG
Chinese Journal of Radiology 2021;55(4):415-419
Objective:To evaluate the value of DWI with background suppression (DWIBS) in evaluating the injury of the low limb nerves in patients with Guillain-Barre syndrome (GBS).Methods:The clinical and imaging data of 30 patients with GBS and 30 healthy volunteers matched with their age and gender in Zibo Central Hospital from January 2018 to December 2019 were analyzed retrospectively. All patients received lower limb nerve electrophysiological examination and all subjects received lower limb nerve DWIBS examination one week later. The display of tibial nerve and common peroneal nerve after DWIBS image reconstruction in normal volunteers and GBS patients was scored by two senior radiologists. Kappa consistency test was used to analyze the consistency of the two senior radiologists′ scores. One-way ANOVA was used to compare the motor nerve conduction velocity (MCV) and motor nerve conduction amplitudes of tibial nerve and common peroneal nerve in patients with GBS among different DWIBS scores. Spearman correlation analysis was used to evaluate the correlation between DWIBS tibial nerve and common peroneal nerve scores and electrophysiological parameters in patients with GBS.Results:In the DWIBS images of 30 healthy volunteers, 60 tibial nerves and common peroneal nerves showed clear, sharp edges, good signal intensity, uniformity, and the scores were 4. The consistency between the two radiologists was good (Kappa value=1.0). In the 60 tibial nerves and common peroneal nerves of 30 GBS patients, 53 tibial nerves and 52 common peroneal nerves showed abnormal changes in varying degrees, including blurred edges, distortions, difficulty in recognition, and weakened signal strength, etc. The consistency between the two readers was good (Kappa value=0.879,0.863,respectively.).With the decrease of DWIBS score, the MCV and motor nerve conduction amplitude values of tibial nerves and common peroneal nervesin GBS patients decreased, and the differences between the score groups were statistically significant ( P<0.01). The scores of tibial nerves and common peroneal nerves in DWIBS were positively correlated with MCV ( r=0.83, 0.84, respectively, P<0.05) and motor nerve conduction amplitude ( r=0.81, 0.79, respectively, P<0.05). Conclusion:DWIBS could provide a three dimensional visualization of tibial nerves and common peroneal nerves, and evaluate the disorders of peripheral nerves in patients with GBS. There has correlation between the scores of tibial nerves and common peroneal nerves in DWIBS with electrophysiology parameters.
10.Epidemiological analysis of 1 940 cases of brucellosis in Hohhot
Ruiping YU ; Meixia WANG ; Mengguang FAN ; Litao SONG ; Na TA ; Xiaoyan LI ; Jingchuan MI
Chinese Journal of Endemiology 2019;38(4):306-309
Objective To understand the epidemiological characteristics of recent brucellosis in Hohhot.Methods Clinical data of patients with brucellosis in Hohhot City were retrospectively analyzed,and the patients were diagnosed in the outpatient clinic of Comprehensive Center for Disease Prevention and Control of Inner Mongolia Autonomous Region from 2014 to 2017.To analyze the patient's area,age,gender,occupation and time distribution of the disease.Results A total of 1 940 patients with brucellosis were diagnosed in Hohhot from 2014 to 2017,with an average age of 50.8 years old.There were 1 464 males with an average age of 50.4 years old and 476 females with an average age of 51.9 years old;the male-female ratio was 3:1.The number of cases of brucellosis in 2014-2017 was 612,649,402,and 277,respectively.Brucellosis was mainly distributed in three districts including Horinger County (937 cases),Tumd Left Banner (236 cases) and Tuoketuo County (191 cases),accounting for 70.31% (1 364/1 940) of the total number of cases in the city.The age of onset was at least 1 year old,the oldest age was 86 years old,and most cases were in the 45-< 65 age group,the total number of cases was 1 046,accounting for 53.92% (1 046/1 940) of the total number of cases in the city;the occupational distribution was mainly farmers (1 795 cases),herders (13 cases) and veterinarians (17 cases),with a total of 1 825 cases,accounting for 94.07% (1 825/1 940).The time distribution was mainly concentrated in March-July,and the number of cases was 1 157 cases.Conclusions The number of brucellosis cases in Hohhot area of Inner Mongolia is mainly from Horinger County,Tumd Left Banner and Tuoketuo County;the cases occur frequently in Spring and Summer;the age of onset is mainly between 45-< 65 years old,they are mainly male farmers.