1.Recent research and progress of medical dressings
Linnan KE ; Xiaoming FENG ; Chunren WANG
Chinese Journal of Tissue Engineering Research 2010;14(3):521-524
BACKGROUND: Medical dressings can play a temporality barrier function as skin substitute in wound healing, which can avoid or control wound infection. With the increasing of aging and chronic ulcer wound, medical dressings play a more important role. OBJECTIVE: To review the recent research and progress of medical dressings, in addition, to explore its developing direction. METHODS: Elsevier database and CNKI was retrieved by computer with key words of "medical dressing, collagen, gel and chitosan" to search papers published between January 1980 and January 2009. Related papers addressing medical dressings were selected. According to inclusion cdteda, 35 literatures were selected Jn this study. RESULTS AND CONCLUSION: Currently, the medical dressings can be classified into natural polymer, synthetic macromolecule, inorganic material and composite. Their performances and clinical application were reviewed respectively. The quality control and future development of medical dressing products were also discussed. This paper can provide a theoretical foundation for the researcher in study and development of medical dressings, manufacturer in the quality control and government in product quality supervision.
2.Determination of fructose and glucose in assisted reproductive culture medium by high performance liquid chromatography-differential refractive index detector
Xue SUN ; Yuanli HUANG ; Linnan KE
Chinese Journal of Tissue Engineering Research 2014;(30):4873-4877
BACKGROUND:Nowadays, the component content of assisted reproductive culture medium and their test methods are unclear in the quality standards. We need to establish the test methods to fil this vacancy, so as to control the quality of assisted reproductive culture medium effectively. OBJECTIVE:To establish an evaluation method for determination of fructose and glucose in assisted reproductive culture medium, thereby based on which to establish the quality standards. METHODS:High performance liquid chromatography-differential refractive index detector was adopted and Rezex RCM-Monosaccharide Ca2+(8%) (300.0 mm×7.8 mm) column was used. The mobile phase was ultrapure water at the flow rate of 0.6 mL/min and the temperature of 80 ℃. RESULTS AND CONCLUSION:Resolution of the peaks of glucose and fructose was 3.2. The linear ranges of glucose and fructose were 30.1-502 mg/L (r=0.999 8) and 102-408 mg/L (r=0.999 8), respectively. The relative standard deviation of reproducibility test was 0.17%and 0.40%, respectively. The relative standard deviation of stability test was 0.22%and 0.73%, respectively. The glucose group and fructose group average recovery rates were 1.22%and 1.38%, respectively. The methodology of High performance liquid chromatography-differential refractive index detector accorded with the requirements. The glucose contents of samples 1 and 2 were 96.7 mg/L and 99.6 mg/L, respectively. The fructose contents of samples 1 and 2 were 208.5 mg/L and 197.4 mg/L, respectively. A reliable, simple, and accurate method was provided for the quality control of assisted reproductive culture medium, which fil s the domestic vacancy in the quality standards for assisted reproductive culture medium.
3.Simultaneous determination of three main bioactive constituents in the in vitro fertilization medium by UHPLC-MSMS
Yuanli HUANG ; Linnan KE ; Chunren WANG ; Zhaopeng YANG
Chinese Journal of Tissue Engineering Research 2017;21(2):291-295
BACKGROUND:In the present quality control file or technique standards of in vitro fertilization medium, the indicators of the component contents and detection methods have not been clearly defined. To ensure the safety and effectiveness of these products, we should establish the quality standards as early as possible. OBJECTIVE:To establish a method for determining the three main bioactive constituents of in vitro fertilizationmedium including glucose, lactic acid sodium salt, pyruvic acid sodium salt by ultra-high performance liquid chromatography tandem mass spectrometric method (UHPLC-MSMS), and to analyze the content of each constituent. METHODS:The UHPLC-MSMS was used, and UHPLC separation was performed on a SUPELCO Discovery HS F5-3 column (15 cm × 2.1 mm, 3μm) in a gradient elute mode with acetonitrile and water (both containing 0.1%formic acid) as the mobile phase at a flow rate of 0.35 mL/min. The column temperature was 40℃. Mass spectrometry detection was performed with multi-reaction monitoring mode using negative electro spray ionization. RESULTS AND CONCLUSION:The linearity was achieved in the range of 0.1-10μg/mL (r=0.999 8) for glucose, 0.05-5μg/mL (r=0.999 4) for lactic acid sodium salt, and 0.1-10μg/mL (r=0.999 4) for pyruvic acid sodium salt. The recoveries were 96.4%-98.1%with relative standard deviation less than 2.8%. To conclude, the UHPLC-MSMS method is sensitive, rapid, accurate and specific, thus providing a basis for the quality standard study of in vitro fertilization medium.
4.Assessment Method of Remnant α-1, 3-galactosyle Epitopes in Animal Tissue-derived Biomaterials.
Yongqiang SHAN ; Liming XU ; Linnan KE ; Yan LU ; Anliang SHAO ; Na ZHANG ; Bixin ZENG
Journal of Biomedical Engineering 2015;32(3):662-679
The aim of this study was to establish an assessment method for determining α-Gal (α-1, 3-galactosyle) epitopes contained in animal tissue or animal tissue-derived biological materials with ELISA inhibition assay. Firstly, a 96 well plate was coated with Gal α-1, 3-Gal/bovine serum albumin (BSA) as a solid phase antigen and meanwhile, the anti-α-Gal M86 was used to react with α-Gal antigens which contained in the test materials. Then, the residual antibodies (M86) in the supernatant of M86-Gal reaction mixture were measured using ELISA inhibition assay by the α-Gal coating plate. The inhibition curve of the ELISA inhibition assay, the R2 = 0.999, was well established. Checking using both α-Gal positive materials (rat liver tissues) and α-Gal negative materials (human placenta tissues) showed a good sensitivity and specificity. Based on the presently established method, the α-Gal expression profile of rat tissues, decellular animal tissue-derived biological materials and porcine dermal before and after decellular treatment were determined. The M86 ELISA inhibition assay method, which can quantitatively determine the α-Gal antigens contained in animal tissues or animal tissue-derived biomaterials, was refined. This M86 specific antibody based-ELISA inhibition assay established in the present study has good sensitivity and specificity, and could be a useful method for determining remnant α-1, 3Gal antigens in animal tissue-derived biomaterials.
Animals
;
Antibodies
;
Biocompatible Materials
;
Enzyme-Linked Immunosorbent Assay
;
methods
;
Epitopes
;
analysis
;
Humans
;
Rats
;
Sensitivity and Specificity
;
Serum Albumin, Bovine
;
Trisaccharides
;
analysis
5.Alpha-Gal antigen and immunity risk control of animal-derived medical devices
Linnan KE ; Yu FANG ; Yongqiang SHAN ; Xiaoming FENG ; Liming XU ; Chunren WANG
Chinese Journal of Tissue Engineering Research 2014;(25):4051-4056
BACKGROUND:Medical devices from animals are commonly used in clinical application. Despite their efficiency is widely accepted, their safety, especialy immunity has been concerned. OBJECTIVE:To investigate immunity risk control to medical devices from animals for safety consideration. METHODS:Using “α-Gal antigen, immunity, xenotransplantation” in Chinese and English as the key words, the first author conducted a computer search of Science direct database (www.sciencedirect.com), Wiley-Blackewel database (http://onlinelibrary.wiley.com) and Wanfang database (www.wanfang.com.cn) through screening the titles and abstracts. RESULTS AND CONCLUSION:Increasing evidence shows that, Gal α1-3Gal antigen (α-Gal antigen) is recognized as the major antigen and abundantly expressed on glycoconjugates of non-primate mammals and New World monkeys. In contrast, the α-gal epitope is not expressed on glycoconjugates of humans and Old World monkeys. Instead, they produce a very large amount of natural anti-α-Gal antibody that specificaly binds the α-gal epitope. The binding of human natural anti-α-Gal to α-gal epitopes expressed on non-primate mammal animals was expected to be unique immunological barrier in xenotransplantation. Therefore, it is important to choose raw materials, reduce or eliminate the α-Ggal epitope, establish highα-Ggal epitope detection methods with high sensitivity and good repeatability for achieving a greater safety and efficiency of medical devices from animals.
6.Establishment and evaluation of intraocular lens loop support force test platform.
Li LIU ; Linnan KE ; Shuo WANG ; Ying WANG ; Haiping REN
Chinese Journal of Medical Instrumentation 2013;37(4):291-293
OBJECTIVEEstablish the test platform of the intraocular lens loop, and the platform was evaluated through the experiment.
METHODSThe intraocular lens loop test platform is made up with three models. The different intraocular lens haptics support force can be completed by replacing different sample holder model.
RESULTSThe standard deviation and the coefficient of variation were calculated through the result of the fifteen samples. The standard deviation was 0.04 mN, and the coefficient of variation was 0.66%. The two values were in the acceptable range.
CONCLUSIONSThe platform was so stabilizing that it could be used to test support force of IOL loop. The different shapes of IOL could be tested on the platform through the replacement of the holder model.
Lenses, Intraocular ; Prosthesis Design
7.Ultrahigh performance liquid chromatography-tandem mass spectrometry determination of glutamine in human assisted reproductive medium
Linnan KE ; Yuanli HUANG ; Yu FANG ; Chunren WANG
Chinese Journal of Tissue Engineering Research 2019;23(10):1594-1598
BACKGROUND: Ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for analyzing amino acids in biological samples is simple in sample preparation with a short analysis time, and has high sensitivity and specificity. Until now, it is only applied in analyzing glutamine contents in dialysate, urine and plasma. OBJECTIVE: To establish a method for determining glutamine concentration in human assisted reproductive media by UPLC-MS/MS. METHODS: The UPLC separation was performed on a SUPELCO Discovery HS F5-3 column (15 cm×2.1 mm, 3 μm) at 40 oC. The mobile phase was acetonitrile and water (both containing 0.1% formic acid) in a gradient elute mode. The flow rate was 0.35 mL/min. Electrospray ionization with a negative-ion and multiple reaction monitoring mode was used. RESULTS AND CONCLUSION: The linearity was achieved in the range of 0.123 7-24.74 mg/L for glutamine (r=0.999 7). The recoveries were 102.9%-108.2% with the range 2.3%-4.9% for the relative standard deviation. The limit of qualification was 9.76 μ g/L. The fertilization culture medium containing glutamine was incubated at 37 oC for 96 hours, in which the glutamine content declined 6% at 24 hours and 15% at 96 hours respectively compared with initial content. Therefore, the method is simple, specific, accurate and sensitive without sample derivation, and the test time is short. It is suitable for the quality control of human assisted reproductive media and useful for the risk study related to the degradation of glutamine.
8.Establishment and Evaluation of Intraocular Lens Loop Support Force Test Platform
Li LIU ; Linnan KE ; Shuo WANG ; Ying WANG ; Haiping REN
Chinese Journal of Medical Instrumentation 2013;(4):291-293
Objective Establish the test platform of the intraocular lens loop, and the platform was evaluated through the experiment. Methods The intraocular lens loop test platform is made up with three models. The different intraocular lens haptics support force can be completed by replacing different sample holder model. Results The standard deviation and the coefficient of variation were calculated through the result of the fifteen samples. The standard deviation was 0.04 mN, and the coefficient of variation was 0.66%. The two values were in the acceptable range. Conclusions The platform was so stabilizing that it could be used to test support force of IOL loop. The different shapes of IOL could be tested on the platform through the replacement of the holder model.
9.Research Status and Safety Considerations of Animal-Derived Mesh Products
Danmei ZHAO ; Chongchong LI ; Lan YU ; Li LIU ; Yuanli HUANG ; Linnan KE
Chinese Journal of Medical Instrumentation 2024;48(5):573-579
With the development of the economy and technological progress,more and more animal-derived mesh products are being utilized in the medical field for tissue and organ repair and replacement.Owing to the complexity of their structure and production process,these animal-derived meshes still face several challenges in practical applications,such as insufficient mechanical strength,rapid degradation rates,and the detection of harmful leachable substances.Among these challenges,the production process is a key factor affecting product quality.This paper reviews the key aspects of the production process and quality control for animal-derived meshes in China,offering new insights for the quality control and regulatory oversight of such products.
10.Current status and quality evaluation of domestic and foreign ophthalmic drug and device combination products
Zhihan WEI ; Yuanli HUANG ; Danmei ZHAO ; Xiaodan DU ; Linnan KE ; Yun XU
China Pharmacist 2024;28(10):350-356
Ophthalmic drug-device combination products are a new method of ophthalmic disease treatment,which is characterized by high bioavailability,strong targeting and good compliance.However,it is difficult for products to be developed and regulated due to the complexity of the human eye structure,drug-device interactions,and other factors.To provide a basis for guaranteeing the safety and efficacy of products development and management,the related regulations,current research,and evaluation of the quality of products are summarized in this paper.