1.Study on purification and properties of lactate dehydrogenase from human erythrocyte
Lingxiang MAO ; Ze MENG ; Lining SHI
Chinese Journal of Clinical Laboratory Science 2001;19(1):4-7
Objective To preparing the reference material(RM) of lactate dehydrogenase(LD),we purification of LD from human erythrocyte(RBC)and studied its properties.Methods Using a modified procedure which including complete hemolysis of the RBC,hydroxyapatite treatment,(NH4)2 SO 4 Precipitation,CM- Sephadex C 50,Sephadex G100 and 5'- AMP- Sepharose 4B affinity chromatography.Results The purified LD has a sepecific activity of 163.0 kU/g protein.It is almost free of contaminating enzymes.Two corresponding bands were observed on both PAG plates stained for either protein or LD activity after electrophresis had been done.The apparent Michaelis constants were of 1.000 and 0.179 mmol/L for L-lactate and NAD and of 0.119 mmol/L 0.062 mmol/L for pyruvate and NADH respectively.Conclusion The final purified LD was found to be very similar to that in human serum in catalytic properties.It is intended to be a fundament to prepare a RM for the measurement of LD.
2.Feasibility study of low-dose scan in 64-slice spiral CT abdominal angiography
Shengxiang XIAO ; Dingli MAO ; Chunhua CHAI ; Lingxiang RUAN ; Wenbo XIAO ; Xianyong ZHOU
Chinese Journal of Radiological Medicine and Protection 2010;30(4):480-482
Objective To explore the feasibility and reasonable of low-dose scan on abdominal angiography in 64-slice spiral helical CT. Methods Phantom test: at 120 KV and from 200 mAs to 30 mAs at an interval of 10 mAs in each image acquisition, it was measured standard deviation (SD) of CT number, high contrast resolution and low contrast resolution, and then analyzed the relationship between the three parameters and the mAs values. Three mAs values were chosen to undertake clinical analysis.Clinical analysis: 90 randomly selected objects with abdominal angiography were divided into three groups,scanning with above three mAs values.Measurement of the SD value at the plain scan images was performed and the enhanced low-dose scan images were used post-processing with three-dimensional volume reconstruction (VR). The VR images were classified into three grades (excellent, moderate, bad) with the blind evaluation of three CT radiologists. The quality-correlation analysis was used between the standard deviation (SD) values of plain scan image and abdominal angiography VR image. Results According to the quality-correlation analysis between the standard deviation (SD) value of plain scan image and abdominal angiography VR image, the area under curve in receiver-operated characteristic (ROC) analysis was 0.921, 0.906 and 0.893 in each three group, respectively. Conclusions The low-dose scan of abdominal angiography is feasible. 80mAs can ensure better image quality. The enhanced scan probably can use 60mAs when the SD value is less than 5.78 in the plain scan; but when the SD value of plain scan is greater than 11.8, the enhanced scan is used best 100 mAs or higher.