1.Randomized comparison of popliteal-sciatic perineural catheter tip migration and dislocation in a cadaver model using two catheter designs.
Lauren STEFFEL ; Steven K HOWARD ; Lindsay BORG ; Edward R MARIANO ; Jody C LENG ; T Edward KIM
Korean Journal of Anesthesiology 2017;70(1):72-76
BACKGROUND: New catheter-over-needle (CON) technology for continuous peripheral nerve blockade has emerged, but its effect on the risk of perineural catheter tip dislocation is unknown. Less flexible catheters may be more likely to migrate away from the nerve with simulated patient movement. In the present study, we evaluated catheter tip migration between CON catheters and traditional catheter-through-needle (CTN) catheters during ultrasound-guided short-axis in-plane (SAX-IP) insertion. METHODS: We evaluated the migration of popliteal-sciatic catheters in a prone, unembalmed male cadaver. Thirty catheter placement trials were divided randomly into two groups based on the catheter type: CON or CTN. A single anesthesiology resident placed the catheters by SAX-IP insertion, and the catheters were then examined by ultrasound before and after ipsilateral knee range of motion (ROM) exercises (0°–130° flexion). A blinded expert regional anesthesiologist performed caliper measurements on the ultrasound images before and after the ROM exercises. The primary outcome was the change in distance from the catheter tip to the center of the nerve (cm) between before and after the ROM exercises. RESULTS: The change in the tip-to-nerve distance (median [10th–90th percentile]) was 0.06 (−0.16 to 0.23) cm for the CTN catheter and 0.00 (−0.12 to 0.69) for the CON catheter (P = 0.663). However, there was a statistically significant increase in dislocation out of the nerve compartment for the CON catheter (4/15; 0/15 for CTN) (P = 0.043). CONCLUSIONS: Although the use of different catheter designs had no effect on the change in the measured migration distance of popliteal-sciatic catheters, 27% of the CON catheters were dislocated out of the nerve compartment. These results may influence the choice of catheter design when using SAX-IP perineural catheter insertion.
Anesthesia, Conduction
;
Anesthesiology
;
Cadaver*
;
Catheters*
;
Dislocations*
;
Exercise
;
Humans
;
Knee
;
Male
;
Nerve Block
;
Peripheral Nerves
;
Range of Motion, Articular
;
Sciatic Nerve
;
Ultrasonography
2.A comparison of strength for two continuous peripheral nerve block catheter dressings.
Lindsay BORG ; Steven K HOWARD ; T Edward KIM ; Lauren STEFFEL ; Cynthia SHUM ; Edward R MARIANO
Korean Journal of Anesthesiology 2016;69(5):506-509
BACKGROUND: Despite the benefits of continuous peripheral nerve blocks, catheter dislodgment remains a major problem, especially in the ambulatory setting. However, catheter dressing techniques to prevent such dislodgment have not been studied rigorously. We designed this simulation study to test the strength of two commercially available catheter dressings. METHODS: Using a cadaver model, we randomly assigned 20 trials to one of two dressing techniques applied to the lateral thigh: 1) clear adhesive dressing alone, or 2) clear adhesive dressing with an anchoring device. Using a digital luggage scale attached to a loop secured by the dressing, the same investigator applied steadily increasing force with a downward trajectory towards the floor until the dressing was removed or otherwise disrupted. RESULTS: The weight, measured (median [10th–90th percentile]) at the time of dressing disruption or removal, was 1.5 kg (1.3–1.8 kg) with no anchoring device versus 4.9 kg (3.7–6.5 kg) when the dressing included an anchoring device (P < 0.001). CONCLUSIONS: Based on this simulation study, using an anchoring device may help prevent perineural catheter dislodgement and therefore premature disruption of continuous nerve block analgesia.
Adhesives
;
Analgesia
;
Anesthesia, Conduction
;
Bandages*
;
Cadaver
;
Catheters*
;
Humans
;
Nerve Block
;
Peripheral Nerves*
;
Research Personnel
;
Thigh
3.Using eye tracking technology to compare the effectiveness of malignant hyperthermia cognitive aid design.
Roderick KING ; Jaber HANHAN ; T Kyle HARRISON ; Alex KOU ; Steven K HOWARD ; Lindsay K BORG ; Cynthia SHUM ; Ankeet D UDANI ; Edward R MARIANO
Korean Journal of Anesthesiology 2018;71(4):317-322
BACKGROUND: Malignant hyperthermia is a rare but potentially fatal complication of anesthesia, and several different cognitive aids designed to facilitate a timely and accurate response to this crisis currently exist. Eye tracking technology can measure voluntary and involuntary eye movements, gaze fixation within an area of interest, and speed of visual response and has been used to a limited extent in anesthesiology. METHODS: With eye tracking technology, we compared the accessibility of five malignant hyperthermia cognitive aids by collecting gaze data from twelve volunteer participants. Recordings were reviewed and annotated to measure the time required for participants to locate objects on the cognitive aid to provide an answer; cumulative time to answer was the primary outcome. RESULTS: For the primary outcome, there were differences detected between cumulative time to answer survival curves (P < 0.001). Participants demonstrated the shortest cumulative time to answer when viewing the Society for Pediatric Anesthesia (SPA) cognitive aid compared to four other publicly available cognitive aids for malignant hyperthermia, and this outcome was not influenced by the anesthesiologists’ years of experience. CONCLUSIONS: This is the first study to utilize eye tracking technology in a comparative evaluation of cognitive aid design, and our experience suggests that there may be additional applications of eye tracking technology in healthcare and medical education. Potentially advantageous design features of the SPA cognitive aid include a single page, linear layout, and simple typescript with minimal use of single color blocking.
Anesthesia
;
Anesthesiology
;
Delivery of Health Care
;
Education, Medical
;
Eye Movements
;
Malignant Hyperthermia*
;
Volunteers