1.Immediate Postoperative Intraocular Pressure Adjustment Reduces Risk of Cystoid Macular Edema after Uncomplicated Micro Incision Coaxial Phacoemulsification Cataract Surgery.
John S JARSTAD ; Allison R JARSTAD ; Gary W CHUNG ; Robert A TESTER ; Linda E DAY
Korean Journal of Ophthalmology 2017;31(1):39-43
PURPOSE: To determine the accuracy of visual estimation of immediate postoperative intraocular pressure (IOP) following microincision cataract surgery (MICS) and the effect of immediate postoperative IOP adjustment on prevention of cystoid macular edema (CME). SETTING: Ambulatory surgical center. METHODS: Prospective, randomized analysis of 170 eyes in 135 patients with MICS, performed in a Medicare approved outpatient ambulatory surgery center. Surgical parameters included a keratome incision of 1.5 mm to 2.8 mm, topical anesthetic, case completion IOP estimation by palpation and patient visualization of light, and IOP adjustment before exiting the operating theater. IOPs were classified into three groups: low (<16 mmHg), normal (16 to 21 mmHg), and elevated (>21 to 30 mmHg). IOP measurements were repeated 1 day after surgery. Optical coherence tomography (Stratus OCT, Zeiss) was measured at 2 weeks. An increase in foveal thickness greater than 15 µm was used to indicate CME. Statistical analysis was performed using one- and two-tailed Student's t-tests. RESULTS: Mean minimal foveal thickness averaged 207.15 µm in the low pressure group, 205.14 µm in the normal IOP group, and 210.48 µm in the elevated IOP group 2 weeks following surgery. CME occurred in 14 of 170 eyes (8.2%) at 2 weeks (low IOP, 35.7%; normal IOP, 14.2%; elevated IOP, 50.0%). Change in IOP from the operating theater to 1 day after surgery was within +/−5 mmHg in 54 eyes (31.7%), elevated by 6 to 15 mmHg in 22 eyes (12.9%), and elevated more than 15 mmHg in four eyes (2.3%). IOP was reduced by 6 mmHg to 15 mmHg in 39 eyes (22.9%) and reduced by more than 15 mmHg in nine eyes (5.3%). CONCLUSIONS: Immediate postoperative adjustment of IOP may prevent CME in MICS. Physicians can improve their ability to estimate postoperative IOP with experience in tonometry to verify immediate postoperative IOP. There are patient safety and economic benefits to immediate IOP adjustment in the operating theater. SYNOPSIS: Immediate postoperative IOP adjustment following cataract surgery before the patient leaves the operating theater may reduce the incidence of CME and provide patient safety and economic benefits.
Ambulatory Surgical Procedures
;
Cataract*
;
Edema
;
Humans
;
Incidence
;
Intraocular Pressure*
;
Macular Edema*
;
Manometry
;
Medicare
;
Outpatients
;
Palpation
;
Patient Safety
;
Phacoemulsification*
;
Prospective Studies
;
Tomography, Optical Coherence
2.Safety of Autologous Umbilical Cord Blood Therapy for Acquired Sensorineural Hearing Loss in Children
Linda S BAUMGARTNER ; Ernest MOORE ; David SHOOK ; Steven MESSINA ; Mary Clare DAY ; Jennifer GREEN ; Rajesh NANDY ; Michael SEIDMAN ; James E BAUMGARTNER
Journal of Audiology & Otology 2018;22(4):209-222
BACKGROUND AND OBJECTIVES: Sensorineural hearing loss (SNHL) in children is associated with neurocognitive morbidity. The cause of SNHL is a loss of hair cells in the organ of Corti. There are currently no reparative treatments for SNHL. Numerous studies suggest that cord blood mononuclear cells (human umbilical cord blood, hUCB) allow at least partial restoration of SNHL by enabling repair of a damaged organ of Corti. Our objective is to determine if hUCB is a safe treatment for moderate to severe acquired SNHL in children. SUBJECTS AND METHODS: Eleven children aged 6 months to 6 years with moderate to severe acquired SNHL were treated with intravenous autologous hUCB. The cell dose ranged from 8 to 30 million cells/kg body weight. Safety was assessed by measuring systemic hemodynamics during hUCB infusion. Infusion-related toxicity was evaluated by measuring neurologic, hepatic, renal and pulmonary function before and after infusion. Auditory function, auditory verbal language assessments and MRI with diffusion tensor imaging (DTI) were obtained before and after treatment. RESULTS: All patients survived, and there were no adverse events. No infusionrelated changes in hemodynamics occurred. No infusion-related toxicity was recorded. Five subjects experienced a reduction in auditory brainstem response (ABR) thresholds. Four of those 5 subjects also experienced an improvement in cochlear nerve latencies. Comparison of MRI with DTI sequences obtained before and after treatment revealed increased fractional anisotropy in the primary auditory cortex in three of five subjects with reduced ABR thresholds. Statistically significant (p < 0.05) reductions in ABR thresholds were identified. CONCLUSIONS: TIntravenous hUCB is feasible and safe in children with SNHL.
Anisotropy
;
Auditory Cortex
;
Body Weight
;
Child
;
Cochlear Nerve
;
Diffusion Tensor Imaging
;
Evoked Potentials, Auditory, Brain Stem
;
Fetal Blood
;
Hair
;
Hearing Loss, Sensorineural
;
Hemodynamics
;
Humans
;
Magnetic Resonance Imaging
;
Mesenchymal Stromal Cells
;
Organ of Corti
;
Umbilical Cord