1.Study on the preparation and stability of sinomenine liposomes
Chinese Traditional Patent Medicine 1992;0(07):-
AIM To study the preparation and stability of sinomenine liposomes. METHODS Taking entrapment efficiency as index, different preparation methods, including thin film dispersion, reverse-phase evaporation, and aether injection were optimized. The leakage rate, the uptake rate and the storage temperature of the liposomes were studied at the same time. RESULTS The entrapment efficiency of reverse-phase evaporation was the lowest as 48.93 % . The entrapment efficiency of thin film dispersion and aether injection were near, as 68.91 T《B》 % and 66.57 % , respectively. CONCLUSION Thin film dispersion has higher entrapment efficiency and low command to the equipment. So it is suitable for the production of sinomenine liposomes on a large scale.
2.Role of transvaginal sonography in diagnosing normal cervix and benign cervical lesions
Chinese Journal of Ultrasonography 2001;10(2):98-100
Objective To evaluate the role of transvaginal sonography in diagnosing the normal cervix and its benign lesions.Methods The one handred and thirty-eight women without malignant findings by colposcopy examination underwent transvaginal sonography within 2 weeks before hyterectomy. The sonography findings were compared with the pathology report.Results Cervical cysts(39 cases) were the most common sonography findings. In 17 cases, endocervical polyps were found sonographically,in 14 cases, myomas were found,and in 27 cases cervicitis were found. The cervix showed no sonographic abnormal in 41. Pathologic results showed 42 cervical cysts, 14 cervical polyps, 16 myomas, 17 cervicitis and 49 normal cervices.Conclusions The sensitivity and specificity of transviginal sonography are high in diagnosing normal cervices and benign cervical lessions. Transviginal sonography provides reliable diagnosing information about the cervix for clinic.
3.Computing method for cuniform gene of electric cuniform board
Chinese Medical Equipment Journal 1993;0(06):-
The cuniform gene of arbitrary angle cuniform board is computed through electric standard cuniform board.
4.Advances of precision radiotherapy
Chinese Medical Equipment Journal 2003;0(11):-
The precision radiotherapy adopts the accurate fixation,immobilization,spacial orientation and 3-dimensional calculation & display methods.On three-dimensional direction,stereotactic conformal or intensity modulated radiation therapy with conventional or non-conventional segmentation method is used.So the high dose area is identical with the target on three-dimensional and the dose intensity modulated in the target.It aims to decrease or not increase the radiation dose in the normal organs and tissues around the target when increasing the radiation dose in the tumor target.The technology can improve the partial control rate and the living quality of the patients.
5.Sonographic appearance of corpus luteum in early pregnance in gray-scale,color and pulsed Doppler ultrasonography
Chinese Journal of Ultrasonography 1993;0(03):-
Objective To understand the gray-scale, color and pulsed Doppler sonographic feature of the corpus luteum during the early trimester of pregnancy. Methods The ovaries of 174 patients with intrauterine gestations between 5 to 9 weeks' menstrual age were examined with transvaginal sonography. Size, sonographic appearance, color Doppler feature, resistance index, peak systolic velocity of the corpus letuem were recorded. Results The corpus luteum was identified in 169 of 174 patients(97.1%) . The mean diameter was ( 1.7 ? 0.8 ) cm. The gray-scale appearances were classified into four types:a thin wall cyst(47 patients, 27.8 %), a thick wall simple cyst(45 patients, 26.6 %), a round hypoechoic structure(43 patients, 25.4 %), a thin-walled cyst containing internal debris (34 patients, 20.1 %). Color blood flow was visualized with color Doppler imaging in 92.3 %(156/169). Color Doppler imaging typically revealed a circumferential rim surrounding part or all of the corpus luteum. Low-resistance blood flow was seen with pulsed Doppler, with a mean resistance index of 0.41?0.10 . Conclusions The corpus lutuem in early pregnancy is identified with transvaginal sonography and has different sonographic appearances. It is important to recognize the various appearances of the corpus lutuem to avoidits confusion with true ovarian abnormalities and ectopic pregnancy.
6.The clinical study of combined vein rearterization for treating thromboangiitis obliterans
Chaosheng WANG ; Hong YIN ; Liling LIU ;
Chinese Journal of General Surgery 1997;0(04):-
Twenty seven patients with obstruction of three branches below popliteal artery were divided into three groups and treated with three different kinds of arterioveinous reversal randomly. The results show that it is better to rebuild ischemic limb circulation with original vein rearterization on the femoral and popliteal planes than to do on the lower deep groups and original great saphenous rearterization for improving symptoms immediately and blood flow at future. It provides a new operation for obstruction of three branches below popliteal artery caused by thromboangiitis obliterans,arteriosclerosis obliterans and other diseases.
7.Clinical Study of Lung Metastases Treated by Fractionated Stereotactic Radiotherapy
Shupeng LUO ; Liling WANG ; Wenda JI
Chinese Medical Equipment Journal 2003;0(10):-
Objective To explore the methods and effects of body fractionated stereotactic radiotherapy(X-knife) in the treatment of lung metastases.Methods There were 50 cases with lung metastases were treated by fractionated stereotactic radiotherapy using CT orientation and WiMRT model body X-knife.The diameter of the metastases was 1.0cm-5.0cm.The linear accelerator was 6Mv X-ray.The dose per fraction was 5-12Gy,and the total prescribed dose was 30-52Gy at the margin of the PTV enveloped by 90% insodose curve.Results The metastases complete regression was found 21 fo-cus(18.3%)in CT image,partial regression in 70 focus(60.9%),and the overall effective rate was 79.1%.The effective rate for the focus with diameter less than 3cm was 88.5%,and 59.4% equal or more than 3cm,there was significan differ-ence(P
8.Quality Assurance for BJ-6B Medical Linear Accelerator
Liling WANG ; Shupeng LUO ; Wenda JI
Chinese Medical Equipment Journal 2003;0(12):-
The quality assurance method for the medical linear accelerator of large-scale radiotherapy equipment is introduced,whose periodic detection and adjustment are discussed.
9.Clinical design of protable and moveable laser light for simulation immobilization
Shupeng LUO ; Liling WANG ; Zhikai YAO
Chinese Medical Equipment Journal 2004;0(08):-
Objective To introduce the clinical design of the portable and moveable laser light for simulation immobilization.Methods According to the theory of the laser immobilization system,the setting is designed by using current material,such as a ruler of ?-shape and pillar-shape laser light etc.After installation and adjustment,it is used in clinic.Results Patient can be immobilized by CT and this setting.Being simple to operate and convenient to use,this setting can act for the expensive laser position system.Conclusion The material and creation of this setting are rougher,so it needs improvement to insure the accuracy of position.
10.Study on drying process for Radix Tripterygii Wilfordii
Xushen WANG ; Liling ZHOU ; Ru LI
Chinese Traditional Patent Medicine 1992;0(04):-
Objective: To determine the condition of drying process for Radix Tripterygii Wilfordii extract. Methods: Under different dying temperature and time, both triptolide and triptophenolide extracted from extract of Radix Tripterygii Wilfordii were measured. Results: After Radix Tripterygii Wilfordi extract was dried for 48 hours at 80 ?C , loss of triptophenolide and triptolide was relatively low, but after dried more than 48 hours at 100 ?C , the content of triptophenolide and triptolide reduced by 15.0%~30.0%. Conclusion: Drying temperature for Radix Tripteryqii Wilfordii extract should be controlled under 80 ?C .