1.Mycobacterium tuberculosis DNA Increases Vitamin D Receptor mRNA Expression and the Production of Nitric Oxide and Cathelicidin in Human Monocytes
Siswanto Siswanto ; Lilik Zuhriyah ; Kusworini Handono ; Loeki Enggar Fitri ; Sumarno Reto Prawiro
Malaysian Journal of Medical Sciences 2015;22(3):18-24
Background: The innate immune response to tuberculosis infection may involve the increased production of nitric oxide and cathelicidin due to the up-regulated expression of the vitamin D receptor (VDR), though this proposed mechanism remains controversial. The aim of this study was to determine how the exposure of human monocytes to Mycobacterium tuberculosis (M. tuberculosis) DNA affects the production of nitric oxide and cathelicidin, as well as the expression of VDR.
Methods: This study was performed using monocytes obtained from healthy donors. After 24 h incubation, monocytes were stimulated with M. tuberculosis DNA for 18 h to determine the expression of VDR mRNA and the production of nitric oxide and cathelicidin versus non-stimulated cells (the control group).
Results: The expression of VDR mRNA was higher in the monocytes exposed to M. tuberculosis DNA compared to the control group (P = 0.020). Monocytes exposed to M. tuberculosis DNA also showed significantly increased production of nitric oxide and cathelicidin compared to the control group (P = 0.0001; P = 0.028).
Conclusion: The stimulation of human monocytes with M. tuberculosis DNA increases the expression of the VDR mRNA and the production of nitric oxide and cathelicidin.
2.Knowledge, Attitudes, and Practices Regarding Dengue Prevention Among Health Volunteers in an Urban Area – Malang, Indonesia
Alidha Nur RAKHMANI ; Lilik ZUHRIYAH
Journal of Preventive Medicine and Public Health 2024;57(2):176-184
Objectives:
The dengue prevention program known as “One House One Mosquito Larva Inspector” involves health volunteers who play a crucial role in the surveillance of mosquito larvae and reporting their findings to local public health officials. This study aimed to identify factors related to the knowledge, attitudes, and practices (KAP) of dengue prevention behavior among these health volunteers.
Methods:
A study was conducted in 5 sub-districts in Malang, an urban area in Indonesia. We employed a cross-sectional design and utilized a semi-structured questionnaire to assess the KAP of 400 health volunteers. Data were collected through face-to-face interviews.
Results:
Multiple logistic regression analysis revealed that individuals with a more positive attitude (odds ratio [OR], 1.69; p<0.05) and those with family sizes greater than five persons (OR, 1.90; p<0.05) were more likely to engage in effective dengue prevention practices. Additionally, possesing good knowledge was significantly assocated with more positive attitude (OR, 2.24; p<0.001). Furthermore, 40% reduction in positive attitude was observed in those over 45 years (OR, 0.60; p<0.05). The best practices most frequently reported by the majority of respondents included always reporting their surveillance activities (75.8%) and cleaning the water container in the bathroom at least once a week (65.2%). However, only 52.2% of respondents regularly checked for mosquito larvae in their neighborhood.
Conclusions
Sustainable promotion and training for the “One House One Mosquito Larva Inspector” initiative are necessary, particularly among young health volunteers, to improve dengue prevention behaviors both within their own homes and in the surrounding environment.
3.Correlations Among Maternal and Infant Factors, Lead Exposure, and Serum Prolactin Levels During Lactation: A Cross-sectional Study in Indonesia
Linda Ratna WATI ; Djanggan SARGOWO ; Tatit NURSETA ; Lilik ZUHRIYAH ; Bambang RAHARDJO
Journal of Preventive Medicine and Public Health 2023;56(5):422-430
Objectives:
Prolactin is vital for breastfeeding and milk production, and its secretion is influenced by factors related to the mother, infant, and environment. To date, no study has concurrently investigated the correlation of these factors with serum prolactin levels during lactation. Therefore, the objective of this study was to investigate the correlations among maternal and infant factors, lead exposure, and serum prolactin levels during lactation.
Methods:
A cross-sectional approach was employed in Surabaya, Indonesia, among 110 exclusively lactating mothers. The mothers’ daily diets were determined using multiple 24-hour recalls, while blood lead levels were measured with inductively coupled plasma mass spectrometry. Serum prolactin levels were assessed using the electrochemiluminescence immunoassay. For bivariate analysis, we employed the Spearman correlation, Mann-Whitney, and Kruskal-Wallis tests, while for multivariate analysis, we utilized multiple linear regression.
Results:
The average serum prolactin level of the lactating mothers was 129.19±88.96 ng/mL. Positive correlations were found between serum prolactin levels and breastfeeding frequency (p < 0.001), protein intake (p < 0.001), and calcium intake (p = 0.011) but had negative correlation with blood lead levels (p < 0.001) and vitamin B6 intake (p = 0.003). Additionally, prolactin levels were not significantly associated with maternal age; parity; intake of calories, vitamin D, vitamin E, zinc, folic acid, magnesium, or iron; infant age; or infant sex.
Conclusions
Breastfeeding frequency had a stronger positive relationship with serum prolactin levels than protein and calcium intake. However, lead exposure was associated with reduced serum prolactin levels during lactation. Consequently, specific interventions from policymakers are necessary to manage breastfeeding in mothers exposed to lead.
4.Correlation of Sit-to-Stand Test and 6-Minute Walk Test to Illustrate Cardiorespiratory Fitness in Systolic Heart Failure Patients
Ivan TRIANGTO ; Aulia Syavitri DHAMAYANTI ; Made Suariastawa PUTRA ; Djoko WITJAKSONO ; Rahmad ; Lilik ZUHRIYAH ; Yoga WARANUGRAHA
Annals of Rehabilitation Medicine 2025;49(1):23-29
Objective:
To prove 5-time sit-to-stand (5-STS) and 30-second sit-to-stand (30sSTS) tests in assessing cardiorespiratory fitness in chronic heart failure (HF) patients with systolic dysfunction. Alternative tests, such as 5-STS and 30sSTS, may be used to assess cardiorespiratory fitness in patients with HF but have not been thoroughly evaluated. Thus, this study aimed to prove 5-STS and 30sSTS tests in assessing cardiorespiratory fitness in chronic HF patients with systolic dysfunction.
Methods:
A cross-sectional study was done, evaluating chronic HF patients with systolic dysfunction that have received optimal guideline directed medical treatment for at least 3 months. All patients underwent the same intervention on the same day, starting with an initial 5-STS test, followed by a 30sSTS, and a 6-minute walk test (6MWT).
Results:
A total of 34 patients were enrolled in this study. The median left ventricular ejection fraction was 44% (interquartile range=34%–48%). Mean values of 5-STS, 30sSTS, and 6MWT were 13.90±4.72, 13.29±3.38, and 463.65±87.04, respectively. 5-STS showed moderate correlation with 6MWT (r=-0.436, p=0.01). However, the 30sSTS revealed strong correlation with 6MWT (r=0.629, p<0.001).
Conclusion
The 30sSTS test had strong correlation with 6MWT. It could be used to illustrate cardiorespiratory fitness in chronic HF patients with systolic dysfunction.
5.Correlation of Sit-to-Stand Test and 6-Minute Walk Test to Illustrate Cardiorespiratory Fitness in Systolic Heart Failure Patients
Ivan TRIANGTO ; Aulia Syavitri DHAMAYANTI ; Made Suariastawa PUTRA ; Djoko WITJAKSONO ; Rahmad ; Lilik ZUHRIYAH ; Yoga WARANUGRAHA
Annals of Rehabilitation Medicine 2025;49(1):23-29
Objective:
To prove 5-time sit-to-stand (5-STS) and 30-second sit-to-stand (30sSTS) tests in assessing cardiorespiratory fitness in chronic heart failure (HF) patients with systolic dysfunction. Alternative tests, such as 5-STS and 30sSTS, may be used to assess cardiorespiratory fitness in patients with HF but have not been thoroughly evaluated. Thus, this study aimed to prove 5-STS and 30sSTS tests in assessing cardiorespiratory fitness in chronic HF patients with systolic dysfunction.
Methods:
A cross-sectional study was done, evaluating chronic HF patients with systolic dysfunction that have received optimal guideline directed medical treatment for at least 3 months. All patients underwent the same intervention on the same day, starting with an initial 5-STS test, followed by a 30sSTS, and a 6-minute walk test (6MWT).
Results:
A total of 34 patients were enrolled in this study. The median left ventricular ejection fraction was 44% (interquartile range=34%–48%). Mean values of 5-STS, 30sSTS, and 6MWT were 13.90±4.72, 13.29±3.38, and 463.65±87.04, respectively. 5-STS showed moderate correlation with 6MWT (r=-0.436, p=0.01). However, the 30sSTS revealed strong correlation with 6MWT (r=0.629, p<0.001).
Conclusion
The 30sSTS test had strong correlation with 6MWT. It could be used to illustrate cardiorespiratory fitness in chronic HF patients with systolic dysfunction.
6.Correlation of Sit-to-Stand Test and 6-Minute Walk Test to Illustrate Cardiorespiratory Fitness in Systolic Heart Failure Patients
Ivan TRIANGTO ; Aulia Syavitri DHAMAYANTI ; Made Suariastawa PUTRA ; Djoko WITJAKSONO ; Rahmad ; Lilik ZUHRIYAH ; Yoga WARANUGRAHA
Annals of Rehabilitation Medicine 2025;49(1):23-29
Objective:
To prove 5-time sit-to-stand (5-STS) and 30-second sit-to-stand (30sSTS) tests in assessing cardiorespiratory fitness in chronic heart failure (HF) patients with systolic dysfunction. Alternative tests, such as 5-STS and 30sSTS, may be used to assess cardiorespiratory fitness in patients with HF but have not been thoroughly evaluated. Thus, this study aimed to prove 5-STS and 30sSTS tests in assessing cardiorespiratory fitness in chronic HF patients with systolic dysfunction.
Methods:
A cross-sectional study was done, evaluating chronic HF patients with systolic dysfunction that have received optimal guideline directed medical treatment for at least 3 months. All patients underwent the same intervention on the same day, starting with an initial 5-STS test, followed by a 30sSTS, and a 6-minute walk test (6MWT).
Results:
A total of 34 patients were enrolled in this study. The median left ventricular ejection fraction was 44% (interquartile range=34%–48%). Mean values of 5-STS, 30sSTS, and 6MWT were 13.90±4.72, 13.29±3.38, and 463.65±87.04, respectively. 5-STS showed moderate correlation with 6MWT (r=-0.436, p=0.01). However, the 30sSTS revealed strong correlation with 6MWT (r=0.629, p<0.001).
Conclusion
The 30sSTS test had strong correlation with 6MWT. It could be used to illustrate cardiorespiratory fitness in chronic HF patients with systolic dysfunction.