1.lntravitreal injection with ranibizumab combined with triamcinolone acetonide sub-Tenon injection for macular edema due to CRVO
Ting-Ting, LI ; Tong-Tong, NIU ; Hai-Lin, WANG
International Eye Science 2015;(1):98-100
Abstract?AlM: To evaluate the efficacy of intravitreal injection with Ranibizumab combined with sub-Tenon injection with Triamcinolone acetonide ( TA ) for macular edema ( ME) due to central retinal venous occlusions ( CRVO) .?METHODS:Forty-six patients (46 eyes) were diagnosed ischemic CRVO with significant macular edema by fundus fluorescence-angiography ( FFA ) and optical coherence tomography ( OCT ) . All the patients had panretinal photocoagulation ( PRP ) , a week after the four times therapies. Twenty-three patients ( 23 eyes ) in group A were randomly chosen to receive intravitreal injection with ranibizumab ( lVR ) , another 23 patients ( 23 eyes ) in group B to treat with both lVR and sub-Tenon injection with TA ( PSTT ) . There was no significant difference on macular edema and best corrected visual activity ( BCVA) between the two groups. The changes in BCVA and central macular thickness ( CMT) before and 1wk; 1, 3, 6mo after treatments were analyzed.?RESULTS: One week after the treatment: the BCVA increased while the CMT decreased compared with that of pretreatment in groups A and B (P<0. 05). BCVA and CMT changes between two groups were statistically significant differences (P<0. 05). One month and three months after the treatment:the BCVA increased while the CMT decreased compared with that of pretreatment in group A and B (P<0. 05), the difference was significant between two groups ( P< 0. 05 ). Six month after the treatment:the BCVA increased while the CMT decreased compared with that of pretreatment in groups A and B. Compare BCVA difference between the groups was statistically significant change (P<0. 05), CMT difference was not statistically significant (P>0. 05).?CONCLUSlON:Not only lVR can decrease ME caused by CRVO and increase the BCVA, but also lVR combined with PSTT can. But combined therapies can be more rapidly and have more positive effect on decreasing the ME and protecting the visual function.
2.Efficacy Observation of Modified Yiqi Chutan Recipe Treating Mid-late Stage NSCLC Patients by CT Perfusion.
Chinese Journal of Integrated Traditional and Western Medicine 2016;36(2):155-159
OBJECTIVETo observe the effect of Modified Yiqi Chutan Recipe (MYCR) on blood flow perfusion in treating mid-late stage non-small cell lung cancer (NSCLC) patients by using multislice CT perfusion (CTP) , and to assess the relationship between each CTP parameter and the prognosis as well.
METHODSTotally 87 mid-late stage NSCLC patients were randomly assigned to the treatment group (44 cases, Shenyi Capsule + MYCR +chemotherapy) and the control group (43 cases, chemotherapy alone) in the ratio of 1:1. And 21 days consisted of 1 therapeutic course, 4 courses in total. All of them underwent CTP of primary tumor and routine thoracic CT examination (plain CT and enhancement CT) 3 times (before therapy, after 2 and 4 cycles). CT findings were analyzed for tumor size and perfusion parameters [blood flow (BF), blood volume (BV), permeability surface (PS), mean transit time (MTT), and time to peak (TP) before and after treatment, and relationship between perfusion parameters and prognosis was also assessed.
RESULTSIn 87 cases, 7 dropped out and 80 cases were available, 40 in the treatment group and 40 in the control group. (1) The relief rate was 47.5% (19/40) and the total stable rate was 77.5% (31/40) in the treatment group, and they were 40.0% (16/40) and 65.0% (26/40) in the control group, with no statistical difference between the two groups (χ² = 0.672, 1.227; P > 0.05). (2) Compared with before treatment group in the same group, BF and PS decreased, and MTT increased in the two groups after 2 and 4 courses (P < 0.05); BE and PS decreased, and MTT increased in the control group after 2 courses (P < 0.05). Compared with the control group after 4 courses, BE decreased more significantly in the treatment group (P < 0.05). (3) After 4 courses, all patients were assigned to the remission group (35 cases) and the non-remission group (45 cases) according to the RECIST standard. Compared with before treatment in the same group, BF, BF, and PS all decreased, and MTT increased in the remission group after treatment (all P < 0.05); BF increased in the non-remission group after treatment (P < 0.05). (4) All patients were assigned to the BE increase group (34 cases) and the BE decrease group (46 cases) according to changed BE values after treatment. Results showed the mean survival rate was 246 days in the BF increase group (the 1-year accumulative survival rate being 13.0%) and 387 days in the BE decrease group (the 1-year accumulative survival rate being 53.1%). The life span was prolonged and the 1-year accumulative survival rate was elevated in the BE increase group, with statistical difference as compared with the BE decrease group (χ² = 19.057, P < 0.01).
CONCLUSIONSShenyi Capsule plus MYCR could reduce BE in mid-late stage NSCLC patients , improve vascular permeability, showing better synergistic effect with chemotherapy. CTP could not only reflect the change of tumor size, but also reflect vascular function of the tumor. Meanwhile, changes of CTP parameters were closely associated with prognosis. Patients with post-treatment decreased BE value had better prognosis and longer life span.
Capillary Permeability ; drug effects ; Carcinoma, Non-Small-Cell Lung ; diagnosis ; drug therapy ; Drugs, Chinese Herbal ; therapeutic use ; Humans ; Phytotherapy ; Tomography, X-Ray Computed
3.The Localization and Expression of Tyrosine Phosphorylated Proteins During In Vitro Capacitation of Guinea Pig Sperm
Li-Juan KONG ; Zhong-Hao LI ; Jian-Yan HUANG ; Ting-Ting DAI ; Gen-Lin WANG ;
China Biotechnology 2006;0(04):-
The aim of this study was to detect the localization and level of tyrosine phosphorylated proteins during in vitro capacitation of guinea pig sperm. Sperm from mature guinea pigs were incubated in modified TALP under 5% CO_2 in air at 37 ℃. The capacitation effect was assessed by chlortetracycline (CTC) staining. Western blotting and indirect immunofluorescence were used to analyze the level and localization of tyrosine phosphorylation. The results showed that guinea pig sperm underwent a time-dependent increase in protein tyrosine phosphorylation during the in vitro capacitation and the percentage of protein tyrosine phosphorylated sperm increased from 36% to 92% from the beginning of incubation to 7h incubation. Also, there was a shift in the site of phosphotyrosine-specific fluorescence from the head of sperm to both the head and the flagellum of sperm. Moreover, there were three proteins phosphorylated in this experiment. After 0 to 0.5h incubation, the protein of 40kDa was detected by anti-phosphotyrosine monoclonal antibody, and the intensity of this protein increased in the following incubation. Then, after 1h incubation, another protein of 80kDa was found and the level of this protein reached the highest point at 3h. Also, in 3h incubation, a protein of 45kDa was detected and the intensity of this protein increased in the following incubation.
4.800 nm diode laser for removing unwanted hair of Ⅲ-Ⅴ skin type
Jun LI ; Beibei CHEN ; Ting JIANG ; Jing LIN ; Jun REN
Chinese Journal of Medical Aesthetics and Cosmetology 2012;(6):407-409
Objective To assess the efficacy and safety of 800 nm diode laser for removing unwanted hair of Ⅲ-Ⅴ skin type.Methods A total of 114 patients were treated with 800 nm diode laser on 234 sites.Four sessions were performed at an interval of 6-8 weeks.Percentage of hair reduction was evaluated 3 months after each session by comparing the terminal hair count to the baseline values.Follow-up was performed 6-8 months after the last session.In addition,subjective satisfaction of physicians and patients was evaluated according to a four-grade scale and the satisfaction rates were calculated.Results After fouth session,97.01% of patients had more than 40 % hair reduction,and 83.33 % patients had more than 60 % hair reduction.Hyperpigmentation was observed on 15 (6.41%) sites,and disappeared after 6-8 months follow-up.The satisfactory rates of the physicians and the patients were 98.25 % and 96.12 %,respectively,with no statistical difference (x2 =3.33,P>0.05).Conclusions 800 nm diode laser for removing unwanted hair of Ⅲ-Ⅴ skin type is a safe and effective treatment option for hair removal,with relatively less side effect.
5.Treatment of acute limb ischemia
Nan LI ; Xinsheng CHEN ; Yunbiao GUAN ; Ting LIN
Chinese Journal of General Surgery 2000;0(12):-
Objective To investigate the management of acute limb ischemia.Methods The clinical data of 28 patients with acute limb ischemia were retrospectively analyzed.Four patients with arterial embolism underwent embolectomy.one patient with pseudoaneurysm underwent false aneurysm resection and revascularization with PTFE,23 patieuts wiht arterial occlusive disease were treated by multiple means such as embolectomy,bypass,primary amputation,endovascular interventions,and pharmacologic therapy(n=23).Results The 5 patients with arterial embolism or pseudoaneurysm were all treated successfully.In the 23 patients with arterial occlusive disease,5(21.7%) were treated successfully,12(52.2%) were improved,and 6(26.1%) had ineffective treatment.No inpatient died,but 4 patients underwent amputation.During follow-up of 6-45 months,there were 4 deaths and other 5 amputations.Conclusions Proper intervention of patients with acute limb ischemia should be chosen according to clinical evaluation of the illness,and includes embolectomy and revascularization,to get limb or life salvage.
6.Study on the HPLC Fingerprint of Gynecological Lotion
Liu YANG ; Ting LI ; Yanbo FAN ; Zheren LIN ; Yisheng ZHANG
China Pharmacist 2017;20(3):463-465
Objective:To establish the HPLC fingerprint detection method for gynecological lotion. Methods:Wondasil C18 (250 mm × 4. 6 mm,5 μm)was selected as the analytical column. The mobile phase was composed of acetonitrile-0. 3% phosphric acid and 0. 3% diethylamine solution with gradient elution at a flow rate of 1. 0 ml·min-1 . The detection wavelength was set at 284 nm and the column temperature was 30℃. Ten batches of gynecological lotion were detected by the HPLC fingerprint and evaluated by Chromato-graphic Fingerprint Evaluation System of Chinese Medicine (2004 edition). Results: The separated peaks were clear and 15 common peaks were identified in the fingerprint of 10 batches of gynecological lotion. Conclusion: The HPLC fingerprint is with good repeat-ability and stability, which can provide evidence for the quality control of gynecological lotion.
7.Prenatal Sonographic Characteristics of Clubfoot and Relationship with Chromosomal Abnormalities
Meifang LIN ; Hongning XIE ; Ju ZHENG ; Ting LEI ; Lan LI
Journal of Sun Yat-sen University(Medical Sciences) 2017;38(2):291-295
[Objective]To evaluate the incidence of chromosomal abnormalities and associated abnormalities in prenatally diag?nosed clubfoot,and to determine the prognostic factors as well.[Methods]A total of 89 fetuses with clubfoot diagnosed during Janu?ary 2010 to October 2015 in prenatal ultrasound scan and confirmed postnatally or by autopsy,were selected,within which 16 (18.0%)cases were without other abnormalities and 73(82.0%)cases were with other abnormalities. The associated abnormalities were identified ,the correlation with chromosomal abnormalities were analyzed with Fisher analysis and the factors affecting the outcomes were determined with Logistic regression analysis.[Results]Among associated abnormalities ,the skeletal abnormalities besides the clubfoot were the most frequently associated anomalies (35 ,47.9%),and the central nervous abnormalities followed secondly(30,41.1%). A chromosomal abnormality,with trisomy 18 being the most frequently detected,was identified in 34%(17/49)of the clubfoot fetuses with other anomalies ,whereas none of chromosomal abnormality was identified in 11 fetuses without other anomalies,a significant different rate of aberrant chromosome noted(P < 0.001). The survival rate of clubfoot fetuses without other anomalies was higher than that of clubfoot fetuses with other anomalies(50.0%vs 1.3%,P=0.03). The conditions of with or without associated anomalies were the independent prognostic factors (P = 0.01),the clubfoot fetuses associated with other anomalies had poor outcomes[OR=11.9(95%CI:1.8,80.1)].[Conclusion]Skeletal abnormalities besides the clubfoot were the most frequently associated anomalies. The condition of with or without associated anomalies is the independent prognostic index for fetuses with clubfoot. Aneuploidy were more commonly in clubfoot fetuses with associated abnormalities than in those without other abnormalities. No indication for karyotyping suggests for the clubfoot fetuses without other abnormalities due to the low incidence of associate chromo?somal anomalies.
8.Study on the clinical value of bedside ultrasound in evaluating the fluid responsiveness in patients with septic shock
Ting LI ; Yanmin KAN ; Lin MA ; Jing BAI ; Junwei ZHANG
Tianjin Medical Journal 2016;44(4):470-473
Objective To study the clinical value of bedside ultrasound in predicting the fluid responsiveness in pa?tients with septic shock in intensive care unit (ICU). Methods Forty-two mechanically ventilated patients with septic shock who admitted to ICU of the Affiliated Hospital of North China University of Science and Technology from January 2015 to April 2015 were included in this study. All patients were treated with volume expansion (VE) text. Hemodynamics in?dexes were obtained by ultrasound before and after each test, including stroke volume (SV), aortic peak blood flow velocity variation rate of breathing (△VpeakAO), inferior vena cava expansion index (△IVC) and brachial artery maximum speed vari?ation rate (△VpeakBA). Clinical data and central venous pressure (CVP) were recorded. Based on the responsiveness of SV, patients were divided into responsive group (R) and non-responsive group (NR), respectively. The differences of the above in?dexes were compared between two groups. The correlation of△IVC,△VpeakAO,△VpeakBA and△SV was determined. The role of the hemodynamic index for predicting volume responsiveness was evaluated by receiver operating characteristic ROC curves. Results A total of 47 VE tests were performed in 42 patients, 25 in R group and 22 in NR group. Before VE test, the hemodynamics indicators of△IVC,△VpeakAO and△VpeakBA were significantly higher in R group compared with those of NR group (P<0.05). The values of△IVC,△VpeakAO and△VpeakBA were positively correlated with△SV in two groups. The areas under the ROC curve of the hemodynamics indicators were 0.825, 0.853 and 0.866 for △IVC, △VpeakAO and△VpeakBA, and they all showed high sensitivity and specificity. Conclusion The hemodynamic index measured by bedside ultrasound can predict the volume responsiveness in mechanically ventilated patients with septic shock fluid therapy, and which can be used to fluid therapy with a high degree of specific and sensitivity in clinical practice.
9.Clinical Investigation of Ultrasound Prediction for Fluid Responsiveness in Patients With Septic Shock
Ting LI ; Yanmin KAN ; Lin MA ; Jing BAI ; Junwei ZHANG
Chinese Circulation Journal 2016;31(4):354-357
Objective: To investigate the ultrasound evaluation on lfuid responsiveness in patients with septic shock. Methods: There 42 septic shock patients treated by mechanical ventilation in our hospital from 2015-01 to 2015-04 were studied. All patients received volume expansion (VE) text, ultrasound examination was conducted to measure hemodynamic parameters of inferior vena cava variation rate of breathing (ΔIVC), aortic peak blood lfow velocity variation rate of breathing (ΔVpeakAO), brachial artery maximum speed variation rate (ΔVpeakBA) and stroke volume (ΔSV) at before and after text. Based on the response to VE text, the patients were divided into 2 groups as Responsive group and Non-responsive group, the above indexes and their correlations to ΔSV were analyzed. The clinical values of those parameters for predicting volume responsiveness were evaluated by ROC curves. Results: A total of 47 VE tests were conducted in 42 patients including 25 cases in Responsive group and 22 cases in Non-responsive group. Before VE test, the parameters of ΔIVC, ΔVpeakAO and ΔVpeakBA were higher in Responsive group than Non-responsive group; ΔIVC, ΔVpeakAO and ΔVpeakBA were obviously related to ΔSV (r=0.631, 0.668 and 0.619). The area of ΔIVC, ΔVpeakAO and ΔVpeakBA under ROC curves were 0.817, 0.853 and 0.866 respectively, they were all with the high sensitivity and speciifcity. Conclusion: Ultrasound monitored hemodynamic parameters may predict the volume responsiveness in septic shock patients with mechanical ventilation, it could be used for guiding liquid treatment in relevant patients.
10.Effects of denture cleansers on color stability and surface roughness of heat-curing denture base resins and elastic denture base materials
Ting LI ; Jun SUN ; Dengyou XU ; Wenjuan MO ; Baoshan LIN
Chinese Journal of Tissue Engineering Research 2017;21(18):2814-2820
BACKGROUND:The occurrence and severity of denture stomatitis are closely related to denture cleaning methods and wearing time. Therefore, it is of great significance to explore the effects of denture cleansers on denture surface roughness and color stability.OBJECTIVE:To investigate the effects of four different denture cleansers on the surface roughness and color stability of heat-curing denture base resins and elastic denture base materials by means of soaking test.METHODS: Samples of heat-curing denture base resins (n=25) and elastic denture base materials (n=25) were polished and soaked in NaClO, Efferdent, Polident partial, Polident overnight and water, respectively. The soak process was repeated 90 times. Then the color aberration and surface roughness were tested using color meter and roughmeter before soaking and after 30, 60, 90 times of soaking.RESULTS AND CONCLUSION:These four kinds of denture cleansers have greater influence on the elastic denture base materials than on the heat-curing denture base resins. With the increasing of soaking time, the color aberration and surface roughness of the two kinds of denture materials were increased gradualy after treatment with different denture cleansers, and the values were ranked as follows: NaClO > Efferdent > Polident overnight > Polident partial and water. To conclude, denture cleansers can induce the changes in denture surface roughness and color stability of heat-curing denture base resins and elastic denture base materials. NaClO exerts the strongest effect, followed by Efferdent and Polident overnight, and Polident partial exhibits the weakest effect.