1.Prophages
Shu LI ; Fu-Quan HU ;
Microbiology 1992;0(03):-
It is common in bacterial genomes of the integration of prophages. As an important participant of the vital movement of their hosts, prophages affect closely the biological properties of the hosts. Therefore, if we want to comprehend a bacterial genome fully, it is essential to recognize and understand accurately prophages in it. This article is a compendious review about the classification, distribution, identification, evolution of prophages and the interaction with their hosts.
2.A Flow Injection Chemiluminescence Method for Determination of Hydrocortisone in Human Serum by Trivalent Silver Complex
Zhaofu FU ; Gongke LI ; Yufei HU
Chinese Journal of Analytical Chemistry 2015;(9):1322-1328
A flow-injection chemiluminescence ( FI-CL ) reaction system with diperiodatoargentateⅢ was developed for the determination of hydrocortisone in human serum. The weak chemiluminescence signal from the reaction between DPA and sulfuric acid system can be greatly enhanced in the presence of hydrocortisone. The optimal conditions of the CL system were 1. 0 mol/L H2SO4, 2. 5×10-4 mol/L diperiodatoargentateⅢ, and flow rate of 4. 20 mL/min. Under the optimal conditions, the CL intensity was linearly to the concentration of hydrocortisone from 3 . 0 × 10-10 g/mL to 1 . 0 × 10-7 g/mL and the detection limit was 2 . 2 × 10-10 g/mL ( 3σ) . The relative standard deviation ( RSD ) was 0 . 6% ( n =11 ) for 5 . 0 × 10-8 g/mL hydrocortisone solution. The proposed method was successfully applied to the direct determination of hydrocortisone in serum samples with the recoveries of 93 . 0%-110 . 0%, and the relative standard deviations were 0 . 3%-3 . 2%. The possible chemiluminescence mechanism was investigated by measuring fluorescence spectra and UV-vis absorption spectra of the system.
3.Bronchoscopy in emergency surgical treatment of massive hemoptysis and treatment procedures
Xin LI ; Hui LI ; Yili FU ; Bin HU
Chinese Journal of Thoracic and Cardiovascular Surgery 2015;31(5):257-259
Objective To promote the successful treatments of massive hemoptysis by summarizing the clinical data of 14 patients receiving surgery.Methods 14 cases of massive hemoptysis were retrospectively analysed,Eight male and 6 femal,aged 27-64 (45 ± 18) years including the application of CT,bronchoscopy and extracorporeal membrane oxygenation (ECMO).Results 14 patients received preoerative bronchoscopy and emergency operation.In addition,hymoptysis had not occurred after the surgery in these cases.Conclusion The standardized clinical pathways for massive hemoptysis and the application of preoerative bronchoscopy is essential for emergency treatment of massive hemoptysis.
4.Mirena IUD on menstrual patterns in patients with adenomyosis and sexual quality of life in clinical research
Qiong FU ; Li HONG ; Lu CHEN ; Bingshu LI ; Min HU
Journal of Chinese Physician 2011;13(4):451-453,457
Objective To investigate the effect on the menstrual patterns and sexual quality of life of patients with adenomyosis after treated with Mirena IUD.Methods56 patients with adenomyosis who were treated with Mirena IUD were recruited from August 2009 to December 2009.We used Menstrual blood loss chart method,Dysmenorrhea score method and Brief Index of Sexual Function for Women (BISF-W) to evaluate the menstrual pattern,the volume of uterus and sexual quality after1,3,6,9,12 months.{Results53 patients were followed up,the rate was 94.6%.The condition of 56 patients became better after treated with Mirena for 3,6,9,12 months,dysmenorrhea[Placed before:(3.15±0.91)points;After placing:(1.41±0.51)points,(0.22±0.09)points,(0.07±0.01)points,0 points]and menstrual quantity[Placed before:(12.0±57.5)points;After placing:(71±23.1)points,(29±19.4)points,(18±10.5)points,(10±4.7)points]were both reduced(P<0.05),the symptoms were not significantly improved after 1 month(P>0.05).D2 indicators was significantly improved after 3 months of treatment (P<0.05),sexual function was also improved after 6 months(P<0.05~0.01).ConclusionsMirena IUD has a good effect on the menstrual pattern and sexual function for patients with adenomyosis.
5.Bronchiectasis combined with pulmonary carcinoma in situ
Xin LI ; Hui LI ; Yili FU ; Bin HU
Chinese Journal of General Practitioners 2014;13(12):1001-1003
Bronchiectasis combined with pulmonary carcinoma in situ is very rare condition.This study reported four cases and reviewed some literatures.The data of 66 cases treated from August 2012 to October 2013,whose initial diagnoses as bronchiectases were analysed.Four cases were diagnosed postoperatively as bronchiectasis with pulmonary carcinoma in situ after sugery,accounted for 6% of surgical patients for bronchiectasis.Bronchiectasis has the risk of combined with pulmonary carcinoma in situ,this should be brought to the attention.
6.The Calculation-Improving of Stress Amplification Coefficient and the Checking of Its Trouble-Shooting Model
Jian-Ren HU ; Da-Ren HU ; Li-Ning FU ; Xie-Ming HU
Chinese Journal of Medical Instrumentation 2001;25(3):146-148
Through mechanical analisis,it is discovered that the twined structure decides the amplification coefficient of the catgut tension.Many troubles of production can be explained with this mechanics model,and it could be used as a reference for medical sulures. The paper gives an accurate calculating formular for catgut design and its direct tensile strength through improving mechanics model. It can raise the material strength from 10 to over 31% depending on its twined structure.
7.Comparative study on Database Performance before and after Upgrading Database and Server
Xiaohui LIU ; Xiaohua LI ; Zhansheng HU ; Qiangchao CHEN ; Jun FU
Chinese Medical Equipment Journal 2003;0(12):-
Objective To perform comparative study on database performance before and after upgrading hardware & software of database. Methods The comparison was carried out from the aspects of hardware expansibility, processing ability, system stability and database performance. Results The reasons for the change of performance and the change law were analyzed. Conclusion After upgrading, the system performance is enhanced greatly.
8.Promoting effect of core competence evaluation on continuing education of training nurses in operation room
Xiaosu HU ; Li GUO ; Qingxin FU ; Jing WANG
Chinese Journal of Practical Nursing 2014;30(20):62-64
Objective To explore the influence of core competence evaluation on continuing education of training nurses in operation room.Methods Questionnaires were administered to 42 training nurses by using the registered nurse core competence scale (CIRN) in operation room.Results The level of core competence of training nurses in operation room was medium (3.25 ± 0.45).Legal and ethical practice dimension of scores was the highest (3.55 ± 0.63).The single average of clinical nursing dimension was the advanced lowest (3.11 ± 0.54).The nurses self identity was the core influencing factors by multiple stepwise regression analysis in regression.Conclusions The core competence of training nurses in operation room is on the middle level,The focus is to improve the ability of clinical nursing in continuing education.To give more attention and support in self identity of the operation room training nurses,and to provide the scientific basis for the training plan and specialist training for them,in order to promote the continuing education projects of training nurses.
10.Analysis of problems existing in using process of micro-perfusion pump by low birth weight infants and the improvement measures
Jing HU ; Chaomei TANG ; Fang LI ; Caihong FU
Chinese Journal of Practical Nursing 2013;29(21):41-43
Objective To make a concrete analysis of micro-perfusion pump and compatible syringes used in neonatal intensive care unit (NICU) for low birth weight infants,and to find solutions to the defects in application.Methods 20 ml sterile syringes were set different infusion rates (1ml/h,5ml/h,6ml/h,10ml/h),different infusion time (5min,30min,lh).Then,the card slot on the micro-perfusion pump where the end of 20ml sterile syringe was placed was regulated.The regulated syringes were also set different infusion rates (5ml/h,6ml/h,l0ml/h) and time as before.The error accuracy was calculated.Results The results showed that at the end stage of 20ml sterile syringes pumping,there was always 0.5~1.5 ml residual liquid which could not be pumped out,but perfusion pump displayed injection was completed.Before regulation,the error accuracy between different infusion rates of 20ml sterile syringes was 6.00%,3.80%,2.33%,1.30% respectively.However,after improvement,the regulated syringes could completely pump all liquid out,and the error accuracy between different infusion rates and different infusion time was also superior to pre-improvement.Conclusions Improved micro-infusion pump and sterile solution prefilled syringe have no drug residual,and display high accuracy and small error accuracy.