1.Hydroxyapatite orbital implant drilling procedure:a follow-up study of 68 cases
Chinese Journal of Medical Aesthetics and Cosmetology 2001;0(04):-
Objective To evaluate the middle and long term effects of the two-stage procedures of drilling for hydroxyapatite orbital implant and inserting a motility peg, and to investigate the pathogenesis and treatment of the various complications during the procedure. Methods This retospective study included 68 patients who had underwent the drilling of the hydroxyapatite and motility peg placement for over 3 years. Mean age at operation was 30.7 years (range from 17~60 years). All patients were placed plastic peg. Information recorded included pre-and post-operative facial appearance, motility of the artificial eye, conjunctival sac discharge and other complications. Results No secondary infection occured in 36~72 months of follow up. All patients felt that there had been an improvement in the motility of their artificial eye. And their cosmetic appearance was acceptable. The most frequent complication encountered was discharge from conjunctiva sac, which occurred in 31 patients. Extrusion of the motility peg was found in 6 patients. 5 patients had exuberant granulation in conjunctiva sac. Conclusion Drilling of the hydroxyapatite implant improves both the appearance and the motility of the artificial eye. Complications are minor and can be easily prevented and treated. The vascularization of HA sphere with good motility should be drilled at relatively larger conjunctival sac in the patients who can cooperate under local anesthesia.
2.Simultaneous Determination of Fluoxertine and Olanzapine in Capsules by HPLC
China Pharmacist 2016;19(10):1975-1977
Objective:To establish a method for the simultaneous determination of fluoxertine and olanzapine in capsules by re-versed-phase high performance liquid chromatography ( RP-HPLC) . Methods:The successful separation of fluoxertine and olanzapine was achieved on a Phenomenex C18 column (250 mm × 4. 6 mm, 5 μm) with 10 mmol·L-1 potassium dihydrogen phosphate buffer (pH 4. 0)-acetonitrile-methanol (55 ∶40 ∶5, v/v/v) as the mobile phase. The flow rate was 1. 0 ml·min-1, the detection wave-length was 227 nm, the column temperature was 30℃, and the injection volume was 20 μl. Results:Fluoxertine could be well separa-ted from olanzapine under the chromatographic conditions. The linearity between the peak areas and the concentrations was observed within the range of 5. 0-80. 0 mg·L-1(r=0. 999 9) for fluoxertine and 1. 2-19. 2 mg·L-1(r=0. 999 9) for olanzapine. The mean recovery of fluoxertine and olanzapine was 99. 9%(RSD=0. 94%, n=9) and 100. 2%(RSD=2. 08%, n=9), respectively. Con-clusion:The method is simple, sensitive and accurate, and it can be applied in the content determination of fluoxertine and olanzapine in capsules.
3.Comparative Study on Dissolution Profiles of Ibuprofen Suspension from Different Pharmaceutical Manu-facturers
China Pharmacist 2016;19(9):1804-1807
Objective:To compare the similarity of dissolution curves of domestic ibuprofen suspension and the imported prepara-tion to provide the basis for the comprehensive quality evaluation of ibuprofen suspension. Methods: The in vitro dissolution of the products from four different manufacturers was investigated in pH 7. 2 phosphate buffer solution. The similarity of dissolution behavior was compared with that of the imported preparation in pH 1. 2 hydrochloric acid solution, pH 4. 5 acetate buffer solution, pH 6. 8 phos-phate buffer solution, pH 7. 2 phosphate buffer solution and water, respectively. Results:The dissolution rate of ibuprofen suspension from the four different manufacturers reached above 80% in 60 min. The dissolution profiles of ibuprofen suspension from two different manufacturers were similar with that of the imported preparation. Conclusion: The dissolution behavior of ibuprofen suspension from different manufacturers is significantly different.
4.The correlation of miR-106a expression with clinical characteristics and prognosis of colon cancer
Yingying FANG ; Yang PAN ; Caihong SONG ; Ying LI ; Qiang LI
Practical Oncology Journal 2014;(3):245-249
Objective To detect the correlations of miR -106 a expression with clinical features of pa-tients with colon cancer ,and to explore the significance of miR -106 a as a prognostic factor .Methods One hun-dred and five patients with primary colon cancer were retrospectively enrolled in this study including their clinical information and slices of FFPE.miR-106a expression was detected by qRT -PCR,and analyzed the correlation between the level of miR -106a and clinical features and survival .Results The level of miR -106a in tumor tissue was higher than adjacent normal tissue (1.142 vs.0.685,P<0.001).miR-106a was correlated with TNM stage and lymphnode metastasis .The higher miR -106a expression,the poorer survival patients were .The hazard risk was increased 3.390 folds(95%CI for HR:1.028 ~11.178)when compared high expression group with the low.Conclusion The aberrant expression of miR -106a may be associated with colon cancer .It will po-tentially be a therapeutic target and prognostic factors .
7.Effect of oral alloy post and core on magnetic resonance imaging.
Fang YIN ; Xin LI ; Qingyun MA ; Lu WANG ; Ye SONG
West China Journal of Stomatology 2014;32(6):588-591
OBJECTIVEThis study aims to observe and compare the influences of the casting alloy post and cores on magnetic resonance imaging (MRI).
METHODSSix casting alloy post and sores were fabricated for the experimental groups, and zirconia post and core served as the control. The seven types of post and cores were of the same size and shape. Each post and core was orally fastened to a volunteer and then imaged with sequences of T1-weighted spin echo imaging (SE-T1WI), T2-weighted turbo spin-echo imaging (TSE-T2WI), and diffusion weighted imaging (DWI).
RESULTSCobalt chromium alloy post and core generated severe artifacts, whereas gold palladium alloy post and core generated no obvious artifacts, and no difference was observed between the zirconia and the gold palladium alloy post and cores (P > 0.05). The pure titanium alloy post and core produced mild artifacts. The post and cores of the titanium, nickel-cadmium, and gold platinum alloys generated moderate artifacts with no significant differences (P > 0.05).
CONCLUSIONDifferent metal post and cores have different influences on MRI. With the exception of that generated by cobalt chromium alloy, the artifact generated by the single-alloy post and core does not influence the image of the normal head and neck.
Alloys ; Artifacts ; Humans ; Magnetic Resonance Imaging ; Post and Core Technique ; Titanium
8.Formulation Optimization and Dissolution of Compound Pearl Powder Effervescent Granule
Yuling SONG ; Zhigang FANG ; Li WU ; Xuenong ZHANG
China Pharmacy 2007;0(36):-
OBJECTIVE:To optimize the formulation of Compound pearl powder effervescent granule and study its release behavior in vitro. METHODS:The contents of anhydrous citric acid,sodium bicarbonate,and lactose in the formulation were optimized by uniform design method with the consumption of ethylenediamine tetraacetic acid(EDTA) as index meanwhile giving consideration to the foaming height and pH of the solution. The dissolution of calcium carbonate in Compound pearl powder effervescent granule,self-made calcium carbonate tablets and self-made pearl power in distilled water and hydrochloric acid were investigated. RESULTS:The optimized formulation of the Compound pearl powder effervescent granule was stated as follows:10.0 g anhydrous citric acid,2.5 g sodium bicarbonate,and 5.0 g lactose. There were significant differences across the 3 different preparations in dissolution rates. CONCLUSION:The prepared Compound pearl powder effervescent granule is characterized by fast and complete drug release. Its solution is acid and indicated for specific population.
9.Current status of health-related productivity loss and its risk factors in nurses
Fang YANG ; Yan YAO ; Hongyan LI ; Jianbo SI ; Wei SONG
Chinese Journal of Health Management 2012;(6):405-408
Objective To explore current status of health-related productivity loss and its risk factors among nurses.Methods Stanford presenteeism scale (SPS-6) and self-designed questionnaire were used to investigate current status of health-related productivity loss and its risk factors among 1122 nurses working in a tertiary hospital in Changchun city.Results Compared with hired nurses,age and work seniority of permanent nurses were significantly higher(Z =-19.49,-19.28 ;P <0.05).The average score of SPS-6 of all the participants was 20.05 ± 4.37.The score of SPS-6 of married nurses was significantly lower than other nurses (Z =-3.52,P < 0.05) ; and the score of SPS-6 of nurses less than 30 years old was significantly higher than those above 30 years old (Z =-2.49,P < 0.05).There were no significant differences between the SPS-6 score of education degree and department.(Z =-1.37,x2 =0.58 ; P >0.05).The result of GLM showed that employment status and work seniority were independent risk factors of health-related productivity loss among nurses.The scores of SPS-6 of permanent nurses was significantly lower than hired nursed (x2 =4.48,P < 0.05),and those who had worked for less than 3 years showed significantly higher score of SPS-6 than those who had worked longer (x2 =12.89,P < 0.05).Conclusions Health-related productivity loss do exist among nurses.Improving health management may help to reduce this loss of productivity.
10.Application of pressure-flow study to diagnosis of female bladder outlet obstruction
Jiangong ZHANG ; Qiang FANG ; Bo SONG ; Weibing LI
Journal of Third Military Medical University 2003;0(24):-
Objective To investigate the value of urodynamic parameters in diagnosing female bladder outlet obstruction.Methods By follow-up investigation,36 out of 54 patients who underwent transurethral vesical neck incision for female bladder outlet obstruction(FBOO)were proven to achieve good therapeutic efficacy,so the clinical diagnosis as FBOO made before treatment was regarded as correct,as FBOO group.Anther 29 asymptomatic healthy female subjects were selected as controls.ROC curve was used to analyze the urodynamic parameters.Results The area under curve,cutoff for diagnosis and their sensitivity and specificity of the parameters were as follows:Q_ max:AUC=0.823,Q_ max≤15 ml/s(SEN=87%,SPE=81%);PdetQ_ max:AUC=0.826,PdetQ_ max≥28.5 cmH_ 2O(SEN=76%,SPE=72%);A-G value:AUC=0.922,A-G value≥1.1(SEN=86%,SPE=86%).Conclusion When Q_ max≤15 ml/s,PdetQ_ max≥28.5 cmH_ 2O and A-G value≥1.1,FBOO is likely to occur in female.