1.The efficacy and safety of radiofrequency ablation in papillary thyroid carcinoma: A systematic review and meta-analysis.
Wei Shuen Clarissa CHEONG ; Xin Yi Joy AU ; Ming Yann LIM ; Ernest Weizhong FU ; Hao LI ; Uei PUA ; Yong Quan Alvin SOON ; Yijin Jereme GAN
Annals of the Academy of Medicine, Singapore 2025;54(3):170-177
INTRODUCTION:
Radiofrequency ablation (RFA) avoids the complications of general anaesthesia, reduces length of hospitalisation and reduces morbidity from surgery. As such, it is a strong alternative treatment for patients with comorbidities who are not surgical candidates. However, to our knowledge, there have only been 1 systematic review and 3 combined systematic review and meta-analyses on this topic to date. This systematic review and meta-analysis seeks to evaluate the efficacy and safety of RFA in the treatment of papillary thyroid carcinoma (PTC) with longer follow-up durations.
METHOD:
PubMed, Embase and Cochrane databases were searched for relevant studies published from 1990 to 2021; 13 studies with a total of 1366 patients were included. The Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines and Sandelowski et al.'s approach1 to "negotiated consensual validation" were used to achieve consensus on the final list of articles to be included. All authors then assessed each study using a rating scheme modified from the Oxford Centre for Evidence-Based Medicine.
RESULTS:
Pooled volume reduction rates (VRRs) from 1 to 48 months after RFA, complete disappearance rates (CDR) and complications were assessed. Pooled mean VRRs were 96.59 (95% confidence interval [CI] 91.05-102.13, I2=0%) at 12 months2-6 and 99.31 (95% CI 93.74-104.88, I2=not applicable) at 48 months.2,5 Five studies showed an eventual CDR of 100%.2,4,7-9 No life-threatening complications were recorded. The most common complications included pain, transient voice hoarseness, fever and less commonly, first-degree burn.
CONCLUSION
RFA may be an effective and safe alternative to treating PTC. Larger clinical trials with longer follow-up are needed to further evaluate the effectiveness of RFA in treating PTC.
Humans
;
Radiofrequency Ablation/methods*
;
Thyroid Cancer, Papillary/surgery*
;
Thyroid Neoplasms/surgery*
;
Treatment Outcome
;
Postoperative Complications/etiology*
3.Forty years of construction and innovative development of scientific regulation system of traditional Chinese medicine in China.
Jun-Ning ZHAO ; Zhi-Shu TANG ; Hua HUA ; Rong SHAO ; Jiang-Yong YU ; Chang-Ming YANG ; Shuang-Fei CAI ; Quan-Mei SUN ; Dong-Ying LI
China Journal of Chinese Materia Medica 2025;50(13):3489-3505
Since the promulgation of the first Drug Administration Law of the People's Republic of China 40 years ago in 1984, China has undergone four main stages in the traditional Chinese medicine(TCM) regulation: the initial establishment of TCM regulation rules(1984-1997), the formation of a modern TCM regulatory system(1998-2014), the reform of the review and approval system for new TCM drugs(2015-2018), and the construction of a scientific regulation system for TCM(2019-2024). Over the past five years, a series of milestone achievements of TCM regulation in China have been achieved in the six aspects, including its strategic objectives and the establishment of a science-based regulatory system, the reform of the review and approval system for new TCM drugs, the optimization and improvement of the TCM standard system and its formation mechanism, comprehensive enhancement of regulatory capabilities for TCM safety, international harmonization of TCM regulation and its role in promoting innovation. Looking ahead, centered on advancing TCMRS to establish a sound regulatory framework tailored to the unique characteristics of TCM, TCM regulation will evolve into new reform patterns, advancing and extending across eight critical fronts, including the legal framework and policy architecture, the review and approval system for new TCM drugs, the quality standard and management system of TCM, the comprehensive quality & safety regulation and traceability system, the research and transformation system for TCMRS, AI-driven innovations in TCM regulation, the coordination between high-quality industrial development and high-level regulation, and the leadership in international cooperation and regulatory harmonization. In this way, a unique path for the development of modern TCM regulation with Chinese characteristics will be pioneered.
Humans
;
China
;
Drugs, Chinese Herbal/standards*
;
History, 20th Century
;
History, 21st Century
;
Medicine, Chinese Traditional/trends*
4.Glucocorticoid Discontinuation in Patients with Rheumatoid Arthritis under Background of Chinese Medicine: Challenges and Potentials Coexist.
Chuan-Hui YAO ; Chi ZHANG ; Meng-Ge SONG ; Cong-Min XIA ; Tian CHANG ; Xie-Li MA ; Wei-Xiang LIU ; Zi-Xia LIU ; Jia-Meng LIU ; Xiao-Po TANG ; Ying LIU ; Jian LIU ; Jiang-Yun PENG ; Dong-Yi HE ; Qing-Chun HUANG ; Ming-Li GAO ; Jian-Ping YU ; Wei LIU ; Jian-Yong ZHANG ; Yue-Lan ZHU ; Xiu-Juan HOU ; Hai-Dong WANG ; Yong-Fei FANG ; Yue WANG ; Yin SU ; Xin-Ping TIAN ; Ai-Ping LYU ; Xun GONG ; Quan JIANG
Chinese journal of integrative medicine 2025;31(7):581-589
OBJECTIVE:
To evaluate the dynamic changes of glucocorticoid (GC) dose and the feasibility of GC discontinuation in rheumatoid arthritis (RA) patients under the background of Chinese medicine (CM).
METHODS:
This multicenter retrospective cohort study included 1,196 RA patients enrolled in the China Rheumatoid Arthritis Registry of Patients with Chinese Medicine (CERTAIN) from September 1, 2019 to December 4, 2023, who initiated GC therapy. Participants were divided into the Western medicine (WM) and integrative medicine (IM, combination of CM and WM) groups based on medication regimen. Follow-up was performed at least every 3 months to assess dynamic changes in GC dose. Changes in GC dose were analyzed by generalized estimator equation, the probability of GC discontinuation was assessed using Kaplan-Meier curve, and predictors of GC discontinuation were analyzed by Cox regression. Patients with <12 months of follow-up were excluded for the sensitivity analysis.
RESULTS:
Among 1,196 patients (85.4% female; median age 56.4 years), 880 (73.6%) received IM. Over a median 12-month follow-up, 34.3% (410 cases) discontinued GC, with significantly higher rates in the IM group (40.8% vs. 16.1% in WM; P<0.05). GC dose declined progressively, with IM patients demonstrating faster reductions (median 3.75 mg vs. 5.00 mg in WM at 12 months; P<0.05). Multivariate Cox analysis identified age <60 years [P<0.001, hazard ratios (HR)=2.142, 95% confidence interval (CI): 1.523-3.012], IM therapy (P=0.001, HR=2.175, 95% CI: 1.369-3.456), baseline GC dose ⩽7.5 mg (P=0.003, HR=1.637, 95% CI: 1.177-2.275), and absence of non-steroidal anti-inflammatory drugs use (P=0.001, HR=2.546, 95% CI: 1.432-4.527) as significant predictors of GC discontinuation. Sensitivity analysis (545 cases) confirmed these findings.
CONCLUSIONS
RA patients receiving CM face difficulties in following guideline-recommended GC discontinuation protocols. IM can promote GC discontinuation and is a promising strategy to reduce GC dependency in RA management. (Trial registration: ClinicalTrials.gov, No. NCT05219214).
Adult
;
Aged
;
Female
;
Humans
;
Male
;
Middle Aged
;
Arthritis, Rheumatoid/drug therapy*
;
Glucocorticoids/therapeutic use*
;
Medicine, Chinese Traditional
;
Retrospective Studies
5.Performance evaluation of Mindray CX-9000 automatic coagulation analyzer
Jia-Quan GUO ; Jiong WEI ; Miao LI ; Ke-Ke LI ; Ming LIU
Chinese Medical Equipment Journal 2024;45(2):58-61
Objective To verify and evaluate the performance of Mindray CX-9000 automatic coagulation analyzer.Methods Myriad CX-9000 automatic coagulation analyzer had its performance validated and evaluated by five routine coagulation tests with reference to the industry including standard prothrombin time(PT),activated partial thromboplastin time(APTT),fibrino-gen(FIB),thrombin time(TT)and D-dimer,so as to clarity whether the analyzer meets the clinical requirements in terms of precision,accuracy,linear range,carry-over and reference interval.Results The five routine coagulation tests had the intra-batch precision CVs lower than 3%,the inter-day precision CVs lower than 5%and the relative deviations of the accuracies within±10%.The slope k of the linear regression equation was 1.006 0 for FIB and 1.013 2 for D-dimer,and the correlation coefficient r was 0.999 3 for FIB and 0.997 5 for D-dimer,which showed high linearity.The carry-over rate of sample concen-tration(CR1)was 4.6%,and the carry-over rate between test items(CR2)was lower than 2%;the R value of the reference interval was 100%;the requirements of industrial standards were met.Conclusion Mindray CX-9000 automatic coagulation analyzer gains advantages in precision,accuracy,linear range and carry-over,and is worthy promoting clinically.[Chinese Medical Equipment Journal,2024,45(2):58-61]
6.Curcumin inhibits lipopolysaccharide-induced differentiation of RAW264.7 cell-derived osteoclasts through regulation of p53/SLC7A11/GPX4 pathway
Ming LI ; Zonghai CHEN ; Qing ZHU ; Lijun YAN ; Zongxing ZHANG ; Quan ZOU ; Longju CHEN
Chinese Journal of Pathophysiology 2024;40(7):1268-1275
AIM:The study aimed to explore the effect of curcumin(Cur)on lipopolysaccharide(LPS)-in-duced RAW264.7 cell-derived osteoclasts,together with its underlying mechanism.METHODS:An osteoclast model was established by treating RAW264.7 cells with LPS.The viability of the cells was assessed by CCK-8 assays and osteo-clast formation was evaluated by tartrate-resistant acid phosphatase(TRAP)activity.The levels of reactive oxygen species(ROS),Fe2+,glutathione(GSH),and malondialdehyde(MDA)were examined by biochemical assays.Mitochondrial morphology was assessed by transmission electron microscopy.The mRNA and protein levels of p53,glutathione peroxi-dase 4(GPX4),and solute carrier family 7 member 11(SLC7A11)were determined by RT-qPCR and Western blot,re-spectively.RESULTS:Treatment with LPS successfully induced osteoclasts formation in RAW264.7 cells.The TRAP results showed that compared with the LPS-treated group,the number of osteoclasts and TRAP activity in the curcumin-treated group decreased dose-dependently(P<0.01).Compared with the control group,the LPS+Erastin group showed significantly increased TRAP activity(P<0.01),while after curcumin treatment,the TRAP activity declined in a dose-de-pendent manner(P<0.01).The results of the biochemical tests showed that compared with the control group,the LPS+Erastin group had significantly elevated levels of ROS,Fe2+,and MDA,while the GSH level was significantly reduced(P<0.01),and compared with the LPS+Erastin group,the ROS,Fe2+,and MDA levels in the curcumin group decreased(P<0.01)and GSH levels increased(P<0.01).These effects were all dose-dependent.Transmission electron microscopy showed that compared with the LPS group,the LPS+Erastin group had reduced mitochondrial cristae and increased mem-brane density,while after treatment with curcumin,both these effects were reversed.The RT-qPCR and Western blot re-sults showed that compared with the control group,the mRNA and protein levels of p53 in the LPS+Erastin group were sig-nificantly increased,while those of of SLC7A11 and GPX4 were significantly reduced(P<0.01).After curcumin treat-ment,the p53 mRNA and protein levels were reduced while the levels of SLC7A11 and GPX4 were increased(P<0.01).CONCLUSION:Curcumin can inhibit lipopolysaccharide-induced differentiation of RAW264.7 cells into osteoclasts,and its mechanism may be related to the inhibition of the p53/SLC7A11/GPX4 signaling pathway.
7.A controlled clinical study of vertebroplasty for the treatment of osteoporotic vertebral compression fractures after self-made spinal positioner and manual reduction
Da WANG ; Shang-Quan WANG ; Ling-Hui LI ; Ming CHEN ; Yong-Kang FENG ; Ming-Yang CAI
China Journal of Orthopaedics and Traumatology 2024;37(6):538-545
Objective To explore clinical effect of manipulation reduction combined with vertebral plasty on osteoporotic compression fractures(OVCFs).Methods Totally 61 patients with OVCFs treated from January 2022 to March 2024 were randomly divided into self-made spinal locator positioning with manipulation reduction group(treatment group)and traditional Kirchner positioning group(control group).There were 30 patients in treatment group,including 4 males and 26 females,aged from 61 to 87 years old with an average of(73.61±7.17)years old;body mass index(BMI)ranged from 15.24 to 28.89 kg·m-2 with an average of(23.90±3.20)kg·m-2;bone mineral density T value ranged from-4.90 to-2.50 SD with an avergae of(-3.43±0.75)SD;fracture to operation time was 6.50(4.00,10.25)d;10 patients were grade Ⅰ,13 patients were grade Ⅱ,and 7 patients were grade Ⅲ according to Genant classification of fracture compression.There were 31 patients in control group,in-cluding 7 males and 24 females,aged from 61 to 89 years old with an average of(73.63±8.77)years old;BMI ranged from 18.43 to 27.06 kg·m-2 with an average of(23.67±2.35)kg·m-2;bone mineral density T value ranged from-4.60 to-2.50 SD with an avergae of(-3.30±0.68)SD;fracture to operation time was 6.00(3.00,8.00)d;1l patients were grade Ⅰ,9 patients were grade Ⅱ,and 11 patients were grade Ⅲ according to Genant classification of fracture compression.The puncture times,X-ray fluoroscopy times and puncture time between two groups were observed and compared.Visual analogue scale(VAS),Japanese Orthopaedic Association(JOA)and timed up and go test(TUGT)were observed and compared before operation,3 d and 1 month after operation.Results All patients were followed up for 1 to 3 months with an average of(2.10±0.80)months.Puncture times,X-ray fluorosecopy times and puncture time in treatment group were 5.00(4.00,6.00)times,(29.53±5.89)times and 14.83(12.42,21.20)min,respectively,while those in control group were 7.00(6.00,8.00)times,(34.58±5.33)times,22.19(17.33,27.01)min,treatment group was better than those of control group(P<0.05).There were no significant differences in preoperative VAS,JOA and TUGT between two groups(P>0.05).VAS,JOA and TUGT in both groups were sig-nificantly improved after opeation(P<0.05).On the third day after operation,JOA score of treatment group was 23.00(20.75,25.00),which was higher than that of control group 20.00(19.00,23.00)(P<0.05).TUGT of treatment group was 6.26(5.86,6.57)s,which was better than that of control group 6.90(6.80,7.14)s(P<0.05).Bone cement leakage occurred with 1 patient in treatment group and 2 patients in control group.Conclusion The optimal scheme of self-made spinal locators for lo-cating descending verteboplasty combined with traditional Chinese medicine reduction manipulation for OVCF patients could reduce the number of intraoperative puncture times,shorten puncture times and reduce number of X-ray fluoroscopy times,and have advantages over the simple positioning of Kirschn's needle in restoring short-term lumbar function and standing and walk-ing ability of postoperative patients.
8.Early gait analysis after total knee arthroplasty based on artificial intelligence dynamic image recognition
Ming ZHANG ; Ya-Nan SUI ; Cheng WANG ; Hao-Chong ZHANG ; Zhi-Wei CAI ; Quan-Lei ZHANG ; Yu ZHANG ; Tian-Tian XIA ; Xiao-Ran ZU ; Yi-Jian HUANG ; Cong-Shu HUANG ; Xiang LI
China Journal of Orthopaedics and Traumatology 2024;37(9):855-861
Objective To explore early postoperative gait characteristics and clinical outcomes after total knee arthroplasty(TKA).Methods From February 2023 to July 2023,26 patients with unilateral knee osteoarthritis(KOA)were treated with TKA,including 4 males and 22 females,aged from 57 to 85 years old with an average of(67.58±6.49)years old;body mass in-dex(BMI)ranged from 18.83 to 38.28 kg·m-2 with an average of(26.43±4.15)kg·m-2;14 patients on the left side,12 pa-tients on the right side;according to Kellgren-Lawrence(K-L)classification,6 patients with grade Ⅲ and 20 patients with grade Ⅳ;the courses of disease ranged from 1 to 14 years with an average of(5.54±3.29)years.Images and videos of standing up and walking,walking side shot,squatting and supine kneeling were taken with smart phones before operation and 6 weeks after operation.The human posture estimation framework OpenPose were used to analyze stride frequency,step length,step length,step speed,active knee knee bending angle,stride length,double support phase time,as well as maximum hip flexion angle and maximum knee bending angle on squatting position.Western Ontario and McMaster Universities(WOMAC)arthritis index and Knee Society Score(KSS)were used to evaluate clinical efficacy of knee joint.Results All patients were followed up for 5 to 7 weeks with an average of(6.00±0.57)weeks.The total score of WOMAC decreased from(64.85±11.54)before op-eration to(45.81±7.91)at 6 weeks after operation(P<0.001).The total KSS was increased from(101.19±9.58)before opera-tion to(125.50±10.32)at 6 weeks after operation(P<0.001).The gait speed,stride frequency and stride length of the affected side before operation were(0.32±0.10)m·s-1,(96.35±24.18)steps·min-1,(0.72±0.14)m,respectively;and increased to(0.48±0.11)m·s 1,(104.20±22.53)steps·min-1,(0.79±0.10)m at 6 weeks after operation(P<0.05).The lower limb support time and active knee bending angle decreased from(0.31±0.38)sand(125.21±11.64)° before operation to(0.11±0.04)s and(120.01±13.35)° at 6 weeks after operation(P<0.05).Eleven patients could able to complete squat before operation,13 patients could able to complete at 6 weeks after operation,and 9 patients could able to complete both before operation and 6 weeks after operation.In 9 patients,the maximum bending angle of crouching position was increased from 76.29° to 124.11° before operation to 91.35° to 134.12° at 6 weeks after operation,and the maximum bending angle of hip was increased from 103.70° to 147.25° before operation to 118.61° to 149.48° at 6 weeks after operation.Conclusion Gait analysis technology based on artificial intelligence image recognition is a safe and effective method to quantitatively identify the changes of pa-tients'gait.Knee pain of KOA was relieved and the function was improved,the supporting ability of the affected limb was im-proved after TKA,and the patient's stride frequency,stride length and stride speed were improved,and the overall movement rhythm of both lower limbs are more coordinated.
9.Treatment of Neer Ⅱ b distal clavicular fracture with locking plate under arthroscope
Shao CHEN ; Cai-Hua ZHANG ; Quan-Ming YANG ; Xin-Chun LI ; Ying-Chun ZHU
China Journal of Orthopaedics and Traumatology 2024;37(10):1010-1014
Objective To investigate the feasibility and clinical effect of the treatment of Neer Ⅱ b distal clavicular fracture with locking plate under arthroscopy.Methods Between June 2018 and September 2022,the medical records of 15 patients with Neer Ⅱ b distal clavicular fracture treated with locking plate under arthroscope were retrospectively analyzed,including 9 males and 6 females,aged from 25 to 57 years old with an average of(42.50±7.75)years old,5 left shoulder,10 right shoul-der,and duration of the disease ranged from 4 to 7 days with an average of(5.16±0.98)d.Visual analog score(VAS),Con-stant-Murley shoulder joint score scale and Neer standard score were used before operation,1 month after operation and the last follow-up.Results All patients successfully completed the treatment of Neer Ⅱ b distal clavicular fracture with locking plate under arthroscopy,with the operation time ranging from 0.3 to 1.0 h with an average of(0.55±0.24)h.All patients were healed at stage Ⅰ.The follow-up time ranged from 6 to 15 months with an average of(9.2±2.8)months.The preoperative VAS score was 7.23±0.67,the Constant-Murley shoulder joint score was(19.57±0.91),and the Neer standard score was(11.27±1.12);The VAS score was(1.56±0.81),the Constant-Murley shoulder joint score was(52.62±1.54),and the Neer standard score was(61.98±2.99)in the first month after operation;At the last follow-up,the VAS was(0.42±0.54),the Constant-Murley shoulder joint score was(91.24±1.97),and the Neer standard score was(93.24±3.38).The difference between VAS,Con-stant-Murley shoulder joint score and Neer standard score was statistically significant at one month postoperative and preoper-ative(P<0.05),and the difference between the last follow-up visit and one month postoperative was statistically significant(P<0.05).Conclusion The treatment of Neer Ⅱ b distal clavicular fracture with locking plate under arthroscope can restore the function of shoulder joint,with definite curative effect and feasibility.
10.Percutaneous balloon mitral valvuloplasty guided by intracardiac echocardiography:a report of two cases
De-Jian LI ; Song CHEN ; Chao XU ; Xue JIANG ; Bo WANG ; Jian-Fei FENG ; Dong-Bang SONG ; Guo-Hui ZHANG ; Ming-Quan WANG ; Wei-Min WANG ; Da-Dong ZHANG
Chinese Journal of Interventional Cardiology 2024;32(5):295-297
For the past 30 years,percutaneous balloon mitral valve dilatation has been performed under the guidance of X-rays and bedside ultrasound.However,there are still some cases of mitral valve stenosis in the large atrium where balloon dilation failed.Intraperitoneal ultrasound-guided percutaneous balloon mitral valve plasty is accurate and feasible,which can reduce the occurrence of complications and improve the success rate of such elderly complex cases.Two patients with severe mitral stenosis underwent percutaneous balloon mitral valve plasty guided by intracardiac ultrasound.The operations were successful without any complications,which can provide reference for clinical treatment of mitral stenosis.

Result Analysis
Print
Save
E-mail