1.Current Status and Proposal of a Guideline for Manual Slide Review of Automated Complete Blood Cell Count and White Blood Cell Dfferential.
Hee Yeon WOO ; Sang Yong SHIN ; Hyosoon PARK ; Young Jae KIM ; Hee Jin KIM ; Young Kyung LEE ; Seok Lae CHAE ; Yoon Hwan CHANG ; Jong Rak CHOI ; Kyungja HAN ; Sung Ran CHO ; Kye Chul KWON
The Korean Journal of Laboratory Medicine 2010;30(6):559-566
BACKGROUND: Manual slide review (MSR) is usually triggered by the results of automated hematolgy analyzers, but each laboaratory has different ciriteria for MSR. This study was carried out to investigate the current status of MSR criteria of automated complete blood cell count (CBC) and white blood cell (WBC) differential results and to propose a basic guideline for MSR. METHODS: Total 111 laboratories were surveyed regarding MSR using questionnaires. The questionnaire asked: kinds of automated hematology analyzers used and the presence of criteria triggering MSR in seven categories: 1) CBC results, 2) 5 differential WBC counts, 3) 3 differential WBC counts, 4) automated reticulocyte counts, 5) delta check, 6) instrument flags (or messages), 7) clinical information (wards or diseases). Based on the survey results, we determined basic and extended criteria for MSR. With these criteria, we consulted nine hematology experts to get a consensus. RESULTS: All 111 laboratories had their own MSR criteria. Among 111 laboratories, 98 (88.3%) used more than three criteria for MSR including CBC results and 5-part WBC differential count results and 95 (85.6%) had criteria of flags triggering MSR. For MSR criteria with numeric values, the 10th, 50th, and 90th percentiles of upper and lower threshold values were obtained. The basic guideline for MSR was made. CONCLUSIONS: We proposed a basic guideline for MSR. This guideline would be helpful to hematology laboratories for their daily operation and providing more rapid and accurate CBC and WBC differential results.
Automation
;
Blood Cell Count/instrumentation/*methods/standards
;
Humans
;
Laboratories, Hospital
;
Leukocyte Count/instrumentation/*methods/standards
;
Quality Control
;
Questionnaires
2.Application of comparison method in internal quality control of hematology analyzer by using fresh blood.
Wen-jun WANG ; Pei-pei WANG ; Xue-fen LI ; Xia-qin GE ; Ming TONG ; Xi-chao GUO
Journal of Zhejiang University. Medical sciences 2008;37(1):88-92
OBJECTIVETo investigate the comparison method on internal control of hematology analyzer by using fresh blood.
METHODSThe hematology analyzer with well function was selected as the reference analyzer, fresh blood samples from healthy subjects were measured by reference analyzer and the values were used to calibrate compared hematology analyzers. The acceptable limits of relative deviation of WBC,RBC, HGB,HCT, PLT were established by comparative experiments during three months. The results of fresh blood samples from patients with low/medium/high levels measured by compared analyzer were compared with those from reference analyzer, the relative deviation of WBC, RBC, HGB, HCT, PLT was calculated respectively. The internal quality control charts in laboratory information system were established, with date as x-axis, relative deviation as y-axis. The acceptable relative deviation limits were set to be +/-2 s, and to be used for laboratory quality control.
RESULTThe relative deviation of WBC, RBC, HGB, HCT, PLT with high, medium, low levels were(0.75+/-2.964)%, (1.19+/-2.488)%,(1.43+/-2.439)%; (-0.39+/-1.327)%, (-0.26+/-1.297)%, (-0.35+/-1.095)%û(-0.43+/-1.393)%, (-0.17+/-1.139)%, (0.24+/-1.166)%û(-.43+/-1.362)%, (-0.36+/-1.381)%, (-0.57+/-1.299)%û(-0.93+/-4.330)%,(0.04+/-4.118)%, (-0.41+/-4.149)%, respectively in 2006. As the second instrument, the compared analyzer was involved in College of American Pathologists Proficiency Testing with satisfactory results, the bias of WBC,RBC, HGB, HCT, PLT were within (-0.5 approximately 5.1)%, (-1.0 approximately 1.6)%, (-1.7 approximately 1.4)%, (-1.5 approximately 1.3)%, (-4.5 approximately 7.4)%, respectively.
CONCLUSIONThe quality control on compared hematology analyzer can be effectively, conveniently and economically performed using this method.
Autoanalysis ; methods ; Blood ; Erythrocyte Count ; instrumentation ; Hematology ; instrumentation ; methods ; standards ; Hemoglobins ; analysis ; Humans ; Leukocyte Count ; instrumentation ; Platelet Count ; instrumentation ; Quality Control ; Reference Standards ; Weights and Measures