1.Accuracy of waist circumference measurement using the WHO versus NIH Protocol in Predicting Visceral Adiposity Using Bioelectrical Impedance Analysis among overweight and obese adult Filipinos in a tertiary hospital
Leslie Daphne Kawaji ; Joy Arabelle Fontanilla
Journal of the ASEAN Federation of Endocrine Societies 2021;36(2):180-188
Objectives:
The study aimed to compare the performance of weight circumference (WC) measurement using the World Health Organization (WHO) versus National Institutes of Health (NIH) protocol in identifying visceral adiposity, and to determine the association of WC with cardiometabolic risk factors among overweight and obese adult Filipinos.
Methodology:
A retrospective study involving 221 subjects (99 males, 122 females) evaluated at an outpatient weight intervention center of a tertiary hospital. The WC was measured at the superior border of the iliac crest (WC-NIH) and midway between the lowest rib and the iliac crest (WC-WHO) for each patient. Using visceral fat rating (VF) derived via bioelectrical impedance analysis (BIA) as reference standard, diagnostic accuracy tests for both protocols (using cut-offs of ≥90 cm in males and ≥80 cm in females) were done. Cardiometabolic parameters were also obtained, and binary logistic regression was performed to determine associations with WC
Results:
Among males, WC-WHO had 96% sensitivity (95% CI 88.8%-99.2%) and 25% specificity (95% CI 9.77%-46.7%) while WC-NIH had 94.7% sensitivity (95% CI 86.9%-98.5%) and 29.2% specificity (95% CI 12.6%-51.1%) to predict high VF >12. Among females, WC-WHO had 100% sensitivity (95% CI 90%-100%) and 24.1% specificity (95% CI 15.6%-34.5%) while WC-NIH had 100% sensitivity (95% CI 90%-100%) and 4.6% specificity (95% CI 1.3%-11.4%). Prevalence of high VF was significantly greater among males – 75.8% (95% CI 66.1%-83.8%) vs. 28.7% (95% CI 20.9%-37.6%) in females (p<0.001). Among females, WC-NIH tended to have higher measurements than WC-WHO by an average of 4.67 cm. Females with WC-WHO measurements of at least 80 cm were approximately four times more likely to have low (<50 mg/dL) HDL levels (cOR 3.82, p=<0.05), even after adjusting for age (aOR 3.83, p=<0.05).
Conclusion
WC measurement using the WHO and NIH protocols were both highly sensitive but had low specificity in predicting high VF estimated via BIA among overweight and obese adult Filipinos in this study. WC-NIH measurements tended to be higher among the females, which may affect classification of central obesity when using this protocol. WC ≥80 cm measured using the WHO protocol was associated with low HDL levels among female subjects. Prospective studies conducted among the general Filipino population are recommended to verify these findings.
Waist Circumference
;
Obesity, Abdominal