1.Research of pulse diagnosis measurement using sensor array in Chinese Medicine
International Journal of Biomedical Engineering 2010;33(4):212-214,219
Objective To develop a new,three dimensional dynamic system for pulse detection.Methods According to bionics,a multi-information sensing mode with a soft surface is designed on the basis of traditional Chinese medical diagnosis in pulse.This mode imitates the touching sense of human finger and with the application of modern computer information processing technique,the pulse information is extracted in the way that is as close as possible to the traditional Chinese medicine pulse diagnosis.Results With the application of new sensor,pulse signal is detected and the effectiveness of the inovative three-dimension data transimition mode is validated since the pulse signal is three-dimensionally re-displayed on the computer screen.Conclusion The method introduced in this paper is proved feasible for detecting pulse information.Expected results are obtained and the method provides a new way and new feature reference for research and teaching in objectifying the diagnosis of traditional Chinese medical sciences.
2.Design of a flexible sensor array for pulse diagnosis in traditional Chinese medicine
Junqi ZHUO ; Lei WANG ; Hong SHA
International Journal of Biomedical Engineering 2015;38(1):15-18,后插4
Objective To acquire high spatial resolution two-dimension pulse pressure distribution for objectifying research of pulse diagnosis in traditional Chinese medicine.Methods A sensor array with flexible packing was designed and implemented.The array was formed on a circle substrate with 37 silicon piezoresistive pressure sensors,which were distributed as equilateral triangles with 1.95 mm pitch.The diameter of the substrate was 15 mm.By using flexible packing,the array had the hardness similar to that of human finger,which made this method closer to the traditional Chinese diagnosis.After differential amplifying,37-way pulse pressure signals were digitalized and reconstructed to obtain the pulse pressure distribution.Results With the application of the sensor array,the pulse pressure signals were measured and transformed into pulse pressure distribution.Conclusions The experimental result contains the relevant characteristics of traditional Chinese pulse diagnosis' description,providing a new way for objective study of traditional Chinese pulse diagnosis and further study.
3.Simulation research on gastric emptying measurement experiment by electrical impedance tomography with three-layer electrodes
Lei WANG ; Shu ZHAO ; Juan DENG ; Yan WANG ; Hong SHA
International Journal of Biomedical Engineering 2016;39(2):107-110,后插4
Objective To verify the effectiveness of electrical impedance tomography (EIT) with multi-layer electrodes in gastric emptying measurement by simulation experiments using EIT with three-layer electrodes.Methods Firstly,EIT system with three-layer electrodes and gastric emptying measurement simulation equipment was designed and constructed to simulate gastric emptying process and obtain EIT reconstruction images.Secondly,the region where the electrical characteristic of gastric changes was selected as region of interest.Finally,the relative impedance change rate in region of interest for every image obtained from all three layers was consecutively recorded,then the gastric emptying curve was formed and gastric emptying time was calculated.Results There are obvious differences among the sharp of impedance change curves of interested region for three layers,and the gastric emptying time and process of each layer is also different from one another.It is suggested that the passing path and emptying manner of food in gastric emptying process reflected by EIT images varied from layer to layer.Therefore,the necessity and feasibility of using EIT with three-layer electrodes in gastric emptying measurement study is verified.Conclusions EIT with three-layer electrodes can provide more abundant information of gastric motility function associated with gastric emptying pathology and physiology state.It is likely to be a noninvasive,convenient and effective imaging method for the detection and evaluation research on gastric emptying and gastric motility.
4.Comparison of Work Mode and Effect Analysis in ICU Area of Our Hospital before and after the Applica-tion of Automated Drug Dispensing System
Fang WANG ; Sha LI ; Wang LU ; Yajing SUN ; Lei CHEN
China Pharmacy 2016;27(19):2660-2662
OBJECTIVE:To promote standard management of drugs in ICU area. METHODS:The change of work mode in ICU area of our hospital was analyzed and compared after the application of automated drug dispensing system(ADDS)as well as the change of related indicators 3 months before and after the application of ADDS;the effect of ADDS was evaluated. RESULTS& CONCLUSIONS:After the application of ADDS,the management of base drugs changed from open management to intelligent, closed-off and authority management;drug storage and cost management became more scientific,and staff allocation became more optimal. Under the condition of zero difference in the number of medical orders,initial medication time shortened from 170 min to 131 min (P<0.05),time of daily drug preparation and drug repercussion shortened from (81.20 ± 3.56)min to (30.04 ± 7.55) min,and (9.18 ± 2.79)min to (6.47 ± 4.66) min (P<0.05). The application of ADDS can improve work efficiency,standardize drug management,promote medical safety,and provide reference for initiating a new mode of drug management in wards.
5.Local impedance measurement method for monitoring and evaluation of injured muscle
Xu WU ; Lei WANG ; Yongjun WANG ; Hong SHA
International Journal of Biomedical Engineering 2014;37(1):26-30
Objective To establish a new methodology of evaluating rehabilitation status of local muscle injured by measuring the impedance and phase information.Methods An evaluation method was set up,which take symmetrical parts of injured muscle as control group during the measurement.Impedance and phase values of injured muscle were extracted with local impedance measurement method before and after rehabilitation to evaluate muscle recovery.Results Injured muscle tissue impedance values decreased significantly.In the process of rehabilitation of injured muscle,the impedance and phase values of the injured muscles were gradually approaching that of healthy muscle,and then achieved basically the same as reference values after rehabilitation.Conclusions Local impedance measurement method may provide a new,non-invasive and convenient evaluation method for the recovery of injured muscle tissue,and it has good prospects for clinical application.
6.Simulation and model experiment research of multichannel impedance gastric motility measurement
Lei WANG ; Yunjie TIAN ; Shu ZHAO ; Hong SHA
International Journal of Biomedical Engineering 2015;38(6):357-360,373,后插10
Objective To study the phase correlation of cutaneous multichannel impedance measurements and the contractions, peristalsis of stomach and the conduction properties in space.Methods A spiral gastric body model was rotated to simulate shrinkage and creep of the stomach.In order to verify the feasibility and validity of the multichannel impedance gastric dynamic measurement, experiments with emulation of multichannel impedance gastric motility measuring principle were conducted through three-dimensional simulation on the electrical characteristics of gastric body model in saline tank simulator.Results The emulation results showed that the change of epigastric current density and potential distribution is consistent with the course of moving from top to bottom when lateral edge of model (namely the intumescent location when the stomach is full) after detecting electrodes in sequence.Meanwhile, the measurement voltage wave forms clearly showed the contraction location of stomach after the model rotating for three cycles in a row, and the phase relationship between adjacent measurement channels was also measured.The sixty seconds data acquired by the experiment device proved that voltage wave form of three measurement channels corresponded to the phase relationship of movement status of the gastric body model.Conclusions Cutaneous multichannel wave forms prove a cyclical movement of stomach, and phase difference among the multichannel signals relating to speed of peristaltic wave, position of the measuring electrodes and channel spacing, etc.This study provides simulation and experimental basis for explanation of quantitative study of conduction properties in space and phase relationship between the results of surface multichannel impedance measurements and the contractions, peristalsis of stomach.
7.Impact of measurement resolution and signal-to-noise ratio of EIT system on reconstruction image
Juan DENG ; Yan WANG ; Shu ZHAO ; Lei WANG ; Hong WANG ; Hong SHA
International Journal of Biomedical Engineering 2015;(3):143-147
Objective Practical electrical impedance tomography (EIT) system with certain measurement resolution (MR) and signal-to-noise ratio (SNR) differs a lot from ideal simulation conditions in EIT methodology research. The aim of this paper was to study the impact of practical system with different MR and SNR on EIT. Methods Based on the ideal simulation boundary voltages of adjacent excitation and adjacent measurement pattern, practical systems whose MR were 0.1 mV and 0.01 mV, SNR ranged from 40-80 dB and no noises were simulated, simulation study for three imaging models A, B and C with different positions in the to-be imaged field under practical system conditions above was carried out using the combined Tikhonov-NOSER regularization algorithm, and error of reconstruction (ER) function and structure similarity (SSIM) function were adopted for quantitative evaluation of image effect. Results There are differences between images obtained under different MR and SNR for different image models. In order to obtain images for three models, SNR of system should be at least 40-50 dB when MR was 0.01 mV. For the goal to obtain high quality images of A, B and C, SNR should be 80, 70 and 60 dB respectively. When MR was 0.1 mV, SNR for obtaining images of A, B, C were 60, 50 and 40 dB. Moreover, the improvement of images with increasing SNR under MR of 0.1 mV was not as obvious as that of MR at 0.01 mV. Conclusions Blind pursuit of single high SNR is of no help to improve system performance and image reconstruction effect except increasing the difficulties in hardware design. The extremity SNR is 50-60 dB for system with MR of 0.01 mV and 60-70 dB for system with MR of 0.1 mV.
8.A portable device for complex electrical bioimpedance information detection
Lei WANG ; Junqi ZHUO ; Xu WU ; Yan WANG ; Shu ZHAO ; Hong SHA
International Journal of Biomedical Engineering 2014;37(2):89-92
Objective To develop and test a high precision medical device which allows measurement of bioimpedance in regions below skin surface,and to enable the assessment of strained muscle's situation and instruct patient's rehabilitation exercise.Methods The system was based on the four-electrode impedance measurement mode and designed by using impedance converter network analyzer AD5933 and monolithic operational amplifier AD844.The hardware consisted of an excitation current source,a response signal adjustment circuit,a digital demodulation circuit and a shield driving circuit.This hardware circuit was combined with a LCD screen and a keyboard,which turned it into a portable precision bioimpedance testing device.Results Using an model of three components as test target,a comparison between the device and the Agilent 4294A precision impedance analyzer was presented.In the range of 1 kHz to 100 kHz,the device showed the similar relative error of the complex impedance's modulus and 1 degree absolute error of the complex impedance's phase.The strained muscle's bioelectrical impedance changes in a clinical case during the convalescent were presented and discussed with the results proven to be clinical meaningful.Conclusions The device is accurate,simple and convenient,which is proved qualified on helping doctors to assess the injury states of the strained muscle and to instruct patient's rehabilitation exercise.
9.Study of ironizing radiation sensitivity decrease of stem cell induced by 635 nm low level laser
Hong WANG ; Qiang LIU ; Hongli CHEN ; Xiaoguang WU ; Lei WANG ; Yingxin LI ; Hong SHA
International Journal of Biomedical Engineering 2015;38(1):25-28,后插5
Objective To study the radioresistance increased by low level laser irradiation (LLLI) in stem cells.Methods Umbilical cord mesenchymal stem cells (UC-MSCs) were divided into control group and experimental groups (LLLI only,γ-ray irradiation only and LLLI combined with γ-ray irradiation groups).635 nm (10 mW/cm2,12 J/cm2) laser irradiation was applied using for 3 days (twice a day),and cells were exposed in 2 Gy dose γ-ray irradiation on the third day.DNA injury was detected by alkaline single cell gel electrophoresis,reactive oxygen species (ROS),superoxide dismutase (SOD) and catalase (CAT) activity were valued using detection kits.Results DNA injury in LLLI combined with γ-ray irradiation group was lower than that in γ-ray irradiation exposed group,activity of oxidation stress kinases was enhanced,and level of ROS was inhibited.Conclusions Ironizing radioresistance of UC-MSCs can be increased after treatment of 635 nm LLLI,which will induce the radiation sensitivity of transplanting cells.
10.Clinical study of effect of mifepristone and gestrinone as a subsidiary treatment after endometriosis surgery
Xiu-Ping ZHANG ; Yi-Na SHA ; Fang WANG ; AZIGULI ; Xiao-Lei XUE ;
Chinese Journal of Primary Medicine and Pharmacy 2006;0(12):-
Objective To evaluate the efficiency and safety of mifepristone and gestrinone in subsidiary treat- ment after endometriosis surgery.Methods Totally 151 patients diagnosed as endometriosis with conservative surgery treatment or laparoscopic operation were divided into three groups;49 cases in the group of mifepristone re- ceived mifepristone tablets 10mg every day for 6 months from the first week of postoperation,60 cases in the group of gestrinone received gestrinone capsules 2.5mg twice every week for 6 months.Cases in the group of control did not receive any postoperative medical treatment.The duration of follow-up after surgery was censored at 3~18 months.Patients'controlling rate of ache symptoms and signs,clinical efficiency,recurrence rate,sex hormone level, menstrual and weight changes,liver and renal functions were recorded and compared.Results The follow up rate is 97.4 %,the efficacious rate and symptoms controlling rate of mifepristone group and gestrinone group were 78.7 %, 93.1% respectively,which of the control group were 34.8 %,58.7 % respectively.There were significant differ- ences,x~2=44.31,P