1.Laboratory analysis on 4 cases of sporadic Vibrio vulnificus infection in Shantou City
Lechuan CHEN ; Hongjun ZHU ; Zeyan ZHOU ; Yongjian KE ; Chuanwen CHEN
Chinese Journal of Infection Control 2016;15(4):272-276
Objective To analyze characteristics of pathogenic microbiology and antimicrobial susceptibility of Vib-rio vulnificus (V.vulnificus)causing infection in patients at a hospital in Shantou City. Methods Four patients with V.vulnificus infection admitted to a hospital between June 2013 and June 2014 were analyzed retrospectively, blood specimens of patients were collected for culture,blister fluid and wound secretion were taken and inoculated on blood agar plates,MacConkey agar plates,and thiosulfate citrate bile salts sucrose (TCBS)plates,isolated strains were identified and performed antimicrobial susceptibility testing. Results Among 4 patients with V. vulnificus infection,3 died,1 was cured;patients developed primary septicemia and lower extremity infection be-cause of eating pickled crab,steamed scallop,or contacting with seafood products after trauma. Blister fluid from patients A and B,wound secretion from patient C,and blood from patient D were all isolated oxidase-positive gram-negative bacteria which produced green colonies on TCBS plate,these strains were identified as V.vulnificus, which were resistant or intermediate to cefazolin,intermediate to cefotetan,and 1 strain was resistant to cefepime. Conclusion Four patients infected with V.vulnificus have high mortality rate (3/4),positive rates of blister fluid and wound secretion are higher than blood;timely medical consultation,early antimicrobial therapy,and active de-bridement will help to cure the disease.
2.Optimal design of portable ambulatory blood pressure monitor based on STM32L.
Mengxing LIU ; Lechuan ZHOU ; Chao HUANG ; Shuming YE ; Hang CHEN
Chinese Journal of Medical Instrumentation 2014;38(5):345-349
Based on the 32-bit ultra low power microcontroller STM32L151RBT6 using ARM Cortex-M3 kernel, the portable ambulatory blood pressure monitor powered by two AA batteries was designed. In order to insure the stability of power supply and prevent overpressure of cuff, super capacitor technology and new kind of safety logic circuits were used. The experimental result shows that: this solution is accurate and stable, which has high safety coefficient and a great clinical application value.
Blood Pressure Monitoring, Ambulatory
;
instrumentation
;
Equipment Design
;
Humans
;
Software