1.A new model of rat artery transplantation
Lailong SUN ; Jianping DU ; Chaobing LIU ; Songlin ZHANG
Chinese Journal of Comparative Medicine 2017;27(5):99-102
Objective Allograft Vasculopathy(AV), which limits the function and long-term survival of transplanted organs, it is the most urgent problem need to be solved in the field of organ transplantation.Traditional vascular anastomosis requires excellent microsurgical techniques, it is difficult to carry out.To explore a simple and feasible AV model can provide ideas for clinical research.Methods We make vessel cannulas by using vein detained needles, pulling the thoracic aorta of donor rat in vessel cannula, both ends turned over and fixed,and then transplant it in recipient rat abdominal aorta.1, 4 and 8 weeks after transplantation, we take out of the transplanted arteries, HE stain, to observe the histomorphology and measurement the vascular intimal thickness.Results 38 of the 40 recipient rats healthy survival to the detection time points, the legs and tail can move freely, defecating and urinating normally.It is found that transplanted arteries concentric circles thickening, its histomorphology just like the AV by using HE staining.Conclutions The method of rats artery transplantation is simple and feasible, significantly shorten the time of abdominal aortic blocking, reduce surgical trauma, can improve the success rate and the reproducibility of operation.
2.Coating for dexamethasone-eluting intravascular stent and its drug sustained release in vitro
Yongpeng CHEN ; Guixue WANG ; Yan CHEN ; Xianchun JIN ; Yanbin HOU ; Lailong LUO ; Dagui SUN
Journal of Third Military Medical University 2003;0(10):-
Objective To prepare the coating of dexamethasone-eluting intravascular stent and observe the features of its delayed release in vitro.Methods Spray painting and dipping coating were used respectively to prepare stent coating,and then high performance liquid chromatography(HPLC)was used to detect the drug loading.The stents prepared by dipping coating were set in a flow of 50 ml PBS buffer at a velocity of 20 ml/min,and 0.5 ml buffer was collected at 6 h and 1,2,4,6,8,10,12,15 d respectively with another 0.5 ml fresh PBS being added immediately.The drug content of the 0.5 ml buffer was detected by HPLC for drug sustained release in vitro.Results The drug loading of stents prepared by spray painting was(24.26?5.23)?g,while that stents prepared by dipping coating for 4 d was(93.15?7.83)?g.Drugs were released slowly and the release rate reached 84% at 15 d.Conclusion The dipping coating-prepared stents have evident effect of sustained release.